View CSAF
1. EXECUTIVE SUMMARY

CVSS v3 9.1
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Chirp Systems
Equipment: Chirp Access
Vulnerability: Use of Hard-coded Credentials

2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker to take control and gain unrestricted physical access to systems using the affected product.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following Chirp Systems are affected:

Chirp Access: All Versions

3.2 Vulnerability Overview
3.2.1 USE OF HARD-CODED CREDENTIALS CWE-798
Chirp Access improperly stores credentials within its source code, potentially exposing sensitive information to unauthorized access.
CVE-2024-2197 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities Sector
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER
Matt Brown reported this vulnerability to CISA.
4. MITIGATIONS
Chirp Systems has not responded to requests to work with CISA to mitigate this vulnerability. Users of the affected product are encouraged to contact Chirp Systems support for additional information.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.
5. UPDATE HISTORY

March 7, 2024: Initial Publication

https://www.cisa.gov/news-events/ics-advisories/icsa-24-067-01