June 2018
Title
SSA-523365 (Last Update: 2018-06-12): Vulnerability in SIMATIC PCS 7
Published
June 12, 2018, 2 a.m.
Summary
The latest software update for SIMATIC PCS 7 fixes a vulnerability, which could allow an attacker to cause a Denial-of-Service (DoS) condition under certain circumstances.
Title
SSA-323211 (Last Update: 2018-06-12): Vulnerabilities in SIPROTEC 4 and SIPROTEC Compact Devices
Published
June 12, 2018, 2 a.m.
Summary
SIPROTEC 4 and SIPROTEC Compact devices are affected by several vulnerabilities. Two of the vulnerabilities could allow attackers to perform a denial-of-service attack under certain conditions. Siemens has released updates for the affected products and will update this advisory when new information becomes available.
Title
SSA-755010 (Last Update: 2018-06-12): Vulnerability in RAPIDLab 1200 and RAPIDPoint 400/500 Blood Gas Analyzers
Published
June 12, 2018, 2 a.m.
Summary
Siemens Healthineers has become aware of two potential cybersecurity vulnerabilities for the RAPIDLab® 1200 Series and RAPIDPoint® 400/405/500 Blood Gas Analyzers and recommends specific countermeasures to mitigate the risk. At the time of advisory publication, no public exploitation of this security vulnerability is known.
Title
SSA-348629 (Last Update: 2018-06-12): Denial-of-Service Vulnerability in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC Software
Published
June 12, 2018, 2 a.m.
Summary
A Denial-of-Service vulnerability has been identified in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC-Software. Siemens has released updates for several affected products and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific countermeasures until patches are available.
Title
SSA-977428 (Last Update: 2018-06-12): Vulnerabilities in SCALANCE M875
Published
June 12, 2018, 2 a.m.
Summary
Multiple vulnerabilities have been identified in the web interface of SCALANCE M875. The web interface of SCALANCE M875 could allow Cross-Site Request Forgery (CSRF), stored Cross-Site Scripting (XSS), or command injection attacks if an attacker is authenticated or tricks a legitimate authenticated user into accessing a malicious link. Siemens recommends ...
May 2018
Title
SSA-168644 (Last Update: 2018-05-29): Spectre and Meltdown Vulnerabilities in Industrial Products
Published
May 29, 2018, 2 a.m.
Summary
Security researchers published information on vulnerabilities known as Spectre and Meltdown. These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Industrial Products include affected processors and are affected by the vulnerabilities.
Title
SSA-457058 (Last Update: 2018-05-23): .NET Security Vulnerability in Siveillance VMS
Published
May 23, 2018, 2 a.m.
Summary
Siemens has released software updates for Siveillance VMS which fix a security vulnerability with the .NET Remoting deserialization that could allow elevation of privileges and/or causing a Denial-of-Service, if affected ports are exposed.
Title
SSA-346262 (Last Update: 2018-05-15): Denial-of-Service in Industrial Products
Published
May 15, 2018, 2 a.m.
Summary
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates ...
Title
SSA-914382 (Last Update: 2018-05-15): Denial-of-Service Vulnerability in SIMATIC S7-400
Published
May 15, 2018, 2 a.m.
Summary
SIMATIC S7-400 CPUs are affected by a security vulnerability which could lead to a Denial-of-Service condition of the PLC if specially crafted packets are received and processed. The affected SIMATIC S7-400 CPU hardware versions are in the product cancellation phase or already phased-out. Siemens recommends customers either upgrading to a ...
Title
SSA-547990 (Last Update: 2018-05-15): Information Disclosure Vulnerabilities in SIPROTEC 4 and SIPROTEC Compact
Published
May 15, 2018, 2 a.m.
Summary
Information disclosure vulnerabilities in SIPROTEC 4 and SIPROTEC Compact devices could allow an attacker to extract sensitive device information under certain conditions. Siemens has released firmware updates for EN100 Ethernet module included in SIPROTEC 4 and SIPROTEC Compact devices. Siemens has also released a firmware update for SIPROTEC Compact 7SJ80 ...
Title
SSA-203306 (Last Update: 2018-05-15): Password Vulnerabilities in SIPROTEC 4 and SIPROTEC Compact Relay Families
Published
May 15, 2018, 2 a.m.
Summary
SIPROTEC 4 and SIPROTEC Compact devices could allow access authorization passwords to be reconstructed or overwritten via engineering mechanisms that involve DIGSI 4 and EN100 Ethernet communication modules. Siemens has released updates for several affected products, is working on updates for the remaining affected products, and recommends specific countermeasures until ...
Title
SSA-689071 (Last Update: 2018-05-09): DNSMasq Vulnerabilities in SCALANCE W1750D, SCALANCE M800 and SCALANCE S615
Published
May 9, 2018, 2 a.m.
Summary
Multiple vulnerabilities have been identified in SCALANCE W1750D, SCALANCE M800, and SCALANCE S615 devices. The highest scored vulnerability could allow a remote attacker to crash the DNS service or execute arbitrary code. The attacker must be able to craft malicious DNS responses and inject them into the network in order ...
Title
SSA-346262 (Last Update: 2018-05-03): Denial-of-Service in Industrial Products
Published
May 3, 2018, 2 a.m.
Summary
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates ...
Title
SSA-293562 (Last Update: 2018-05-03): Vulnerabilities in Industrial Products
Published
May 3, 2018, 2 a.m.
Summary
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct Layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released updates for ...
Title
SSA-546832 (Last Update: 2018-05-03): Vulnerabilities in Medium Voltage SINAMICS Products
Published
May 3, 2018, 2 a.m.
Summary
The latest updates for medium voltage SINAMICS products fix two security vulnerabilities that could allow an attacker to cause a Denial-of-Service condition either via specially crafted PROFINET DCP broadcast packets or by sending specially crafted packets to port 161/udp (SNMP). Precondition for the PROFINET DCP scenario is a direct Layer ...
Title
SSA-457058 (Last Update: 2018-05-03): .NET Security Vulnerability in Siveillance VMS
Published
May 3, 2018, 2 a.m.
Summary
Siemens has released software updates for Siveillance VMS which fix a security vulnerability with the .NET Remoting deserialization that could allow elevation of privileges and/or causing a Denial-of-Service, if affected ports are exposed.
Title
SSA-468514 (Last Update: 2018-05-03): Improper Certificate Validation Vulnerability in Siveillance VMS Video Mobile App for Android and iOS
Published
May 3, 2018, 2 a.m.
Summary
The latest update for the Siveillance VMS Video mobile app for Android and iOS fixes a security vulnerability that could allow an attacker in a privileged network position to read data from and write data to the encrypted communication channel between the app and a server. Precondition for this scenario ...
April 2018
Title
SSA-348629 (Last Update: 2018-04-18): Denial-of-Service Vulnerability in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC Software
Published
April 18, 2018, 2 a.m.
Summary
A Denial-of-Service vulnerability has been identified in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC-Software. Siemens has released updates for several affected products and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific countermeasures until patches are available.
Title
SSA-892715 (Last Update: 2018-04-18): ME, SPS and TXE Vulnerabilities in SIMATIC IPCs
Published
April 18, 2018, 2 a.m.
Summary
Intel has identified vulnerabilities in Intel Management Engine (ME), Intel Server Platform Services (SPS), and Intel Trusted Execution Engine (TXE). As several Siemens Industrial PCs use Intel technology, they are also affected. Siemens has released updates for the affected Industrial PCs.
Title
SSA-597741 (Last Update: 2018-04-18): Vulnerability in iOS App SIMATIC WinCC OA Operator
Published
April 18, 2018, 2 a.m.
Summary
The SIMATIC WinCC OA Operator iOS app is affected by a security vulnerability which could allow an attacker to read unencrypted data from the application’s directory. Precondition for this scenario is that an attacker has physical access to the mobile device.
Title
SSA-168644 (Last Update: 2018-04-18): Spectre and Meltdown Vulnerabilities in Industrial Products
Published
April 18, 2018, 2 a.m.
Summary
Security researchers published information on vulnerabilities known as Spectre and Meltdown. These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Industrial Products include affected processors and are affected by the vulnerabilities.
Title
SSA-203306 (Last Update: 2018-04-17): Password Vulnerabilities in SIPROTEC 4 and SIPROTEC Compact Relay Families
Published
April 17, 2018, 2 a.m.
Summary
SIPROTEC 4 and SIPROTEC Compact devices could allow access authorization passwords to be reconstructed or overwritten via engineering mechanisms that involve DIGSI 4 and EN100 Ethernet communication modules. Siemens has released updates for several affected products, is working on updates for the remaining affected products, and recommends specific countermeasures until ...
Title
SSA-845879 (Last Update: 2018-04-17): Firmware Downgrade Vulnerability in EN100 Ethernet Communication Module for SIPROTEC 4, SIPROTEC Compact and Reyrolle
Published
April 17, 2018, 2 a.m.
Summary
The EN100 Ethernet communication module, which is an optional extension for SIPROTEC 4, SIPROTEC Compact and Reyrolle devices, allows an unauthenticated upload of firmware updates to the communication module in affected versions. Siemens has released updates for several affected products, is working on updates for the remaining affected products, and ...
Title
SSA-901333 (Last Update: 2018-04-05): KRACK Attacks Vulnerabilities in Industrial Products
Published
April 5, 2018, 2 a.m.
Summary
Multiple vulnerabilities affecting WPA/WPA2 implementations were identified by a researcher and publicly disclosed under the term "Key Reinstallation Attacks" (KRACK). These vulnerabilities could potentially allow an attacker within the radio range of the wireless network to decrypt, replay or inject forged network packets into the wireless communication. Several Siemens Industrial ...
Title
SSA-689071 (Last Update: 2018-04-05): DNSMasq Vulnerabilities in SCALANCE W1750D, SCALANCE M800 and SCALANCE S615
Published
April 5, 2018, 2 a.m.
Summary
Multiple vulnerabilities have been identified in SCALANCE W1750D, SCALANCE M800, and SCALANCE S615 devices. The highest scored vulnerability could allow a remote attacker to crash the DNS service or execute arbitrary code. The attacker must be able to craft malicious DNS responses and inject them into the network in order ...