SIEMENS CERT
02/11/2025
Affected SIPROTEC 5 devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the sensitive information from the filesystem of the device. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are …
SIEMENS CERT
02/11/2025
The Tableau Server component in Opcenter Intelligence contains multiple vulnerabilities as described below. Siemens has released a new version for Opcenter Intelligence and recommends to update to the latest version and to install the latest available version of Tableau Server as described in https://support.sw.siemens.com/knowledge-base/PL8822108.
SIEMENS CERT
02/11/2025
The webserver of several SIMATIC products is affected by a user enumeration vulnerability that could allow an unauthenticated remote attacker to identify valid usernames. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific …
SIEMENS CERT
02/11/2025
SINEC Traffic Analyzer before V1.2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC Traffic Analyzer and recommends to update to the latest version.
US CERT
01/15/2025
Note: The CVEs in this advisory are unrelated to vulnerabilities (CVE-2025-0282 and CVE-2025-0283) in Ivanti’s Connect Secure, Policy Secure and ZTA Gateways. For more information on mitigating CVE -2025-0282 and CVE-2025-0283, see Ivanti Releases Security Updates for Connect Secure, Policy Secure, and ZTA Gateways. Summary The Cybersecurity and Infrastructure Security …
BOSCH PSIRT
01/15/2025
BOSCH-SA-904062-BT: An unquoted service path enumeration vulnerability on SMCWatchDog agent has been found affecting the DIVAR IP all-in-one 7000 (DIP-72xx) devices. This vulnerability can allow a local attacker to gain elevated privileges.
SIEMENS CERT
01/15/2025
Several camera device drivers in the Siveillance Video Device Pack store camera credentials in their log file when authentication fails. This could allow a local attacker to read camera credentials stored in the Recording Server under specific conditions. Siemens has released an update of the Device Pack and recommends to …
SIEMENS CERT
01/14/2025
SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released a new version for SCALANCE W-700 IEEE 802.11ax family and recommends to update to the latest version. Siemens recommends countermeasures for vulnerabilities where fixes are not, or not yet available.