SSA-349422 V1.5 (Last Update: 2021-02-09): Denial-of-Service in Industrial Real-Time (IRT) Devices
Veröffentlicht
9. Februar 2021 01:00
Text
A vulnerability in the affected products could allow an unauthorized attacker with network access to perform a denial-of-service attack resulting in loss of real-time synchronization. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures ...
Titel
SSA-398519 V1.5 (Last Update: 2021-02-09): Vulnerabilities in Intel CPUs (November 2019)
Veröffentlicht
9. Februar 2021 01:00
Text
Intel has published information on vulnerabilities in Intel products in November 2019. In this advisory Siemens only explicitly mentions the vulnerabilities from the “Intel® CPU Security Advisory” and one vulnerability from “Intel® CSME, Intel® SPS, Intel® TXE, Intel® AMT, Intel® PTT and Intel® DAL Advisory” and lists the Siemens IPC ...
Titel
SSB-439005 V3.1 (Last Update: 2021-02-09): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Veröffentlicht
9. Februar 2021 01:00
Text
Januar 2021
Titel
SSA-520004 V1.0: Telnet Authentication Vulnerability in SIMATIC HMI Comfort Panels
Veröffentlicht
28. Januar 2021 01:00
Text
SIMATIC HMI Panels are affected by a vulnerability that could allow a remote attacker to gain full access to the device(s), if the telnet service is enabled. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
Denial of Service in Rexroth ID 200/C-ETH using EtherNet/IP Protocol
Veröffentlicht
27. Januar 2021 01:00
Text

BOSCH-SA-775371: The ID 200/C-ETH (Rexroth No. 3842 410 060) sold by Bosch Rexroth contains communication technology (499ES EtherNet/IP) from Real Time Automation (RTA) in which a critical vulnerability has been discovered. By exploiting the vulnerability an attacker can send a specially crafted packet that may result in a denial-of-service condition ...

Titel
Two Vulnerabilities in Bosch Fire Monitoring System (FSM)
Veröffentlicht
21. Januar 2021 01:00
Text

BOSCH-SA-332072-BT: Two vulnerabilties have been discovered affecting the Bosch Fire Monitoring System (FSM-2500 and FSM-5000). The critical issue applies to FSM systems with versions 5.2 and lower. Bosch rates these vulnerabilities with a CVSS v3.1 Base Score of 4.4 and 10.0 (medium and critical) and strongly recommends customers to update ...

Titel
SSA-646763 V1.0: DNSpooq - Dnsmasq Vulnerabilities in SCALANCE and RUGGEDCOM Devices
Veröffentlicht
19. Januar 2021 01:00
Text
Security researchers discovered and disclosed seven vulnerabilities in the open-source DNS component “dnsmasq”, also known as “DNSpooq” vulnerabilities (CVE-2020-25681 through CVE-2020-25687). Three vulnerabilities (CVE-2020-25684 through CVE-2020-25686) affect the validation of DNS responses and impact several SCALANCE and RUGGEDCOM devices as listed below. Siemens is preparing updates and recommends countermeasures for ...
Titel
SSA-979834 V1.1 (Last Update: 2021-01-15): Multiple vulnerabilities in Solid Edge
Veröffentlicht
15. Januar 2021 01:00
Text
Solid Edge is affected by multiple vulnerabilities that could allow arbitrary code execution on an affected system. Siemens has released an update for Solid Edge and recommends to update to the latest version.
Titel
SOOIL Dana Diabecare RS Products
Veröffentlicht
12. Januar 2021 17:00
Text
This advisory contains mitigations for Use of Hard Coded Credentials, Insufficiently Protected Credentials, Use of Insufficiently Random Values, Use of Client-side Authentication, Client-side Enforcement of Server-side Security, Authentication Bypass by Capture-Replay, Unprotected Transport of Credentials, Key Exchange Without Entity Authentication, and Authentication Bypass by Spoofing vulnerabilities in SOOIL Dana Diabecare ...
Titel
Schneider Electric EcoStruxure Power Build-Rapsody
Veröffentlicht
12. Januar 2021 16:55
Text
This advisory contains mitigations for an Unrestricted Upload of File with Dangerous Type vulnerability in the Schneider Electric EcoStruxure Power Build-Rapsody software.
Titel
Siemens JT2Go and Teamcenter Visualization
Veröffentlicht
12. Januar 2021 16:45
Text
This advisory contains mitigations for a Type Confusion, Improper Restriction of XML External Entity Reference, Out-of-bounds Write, Heap-based Buffer Overflow, Stack-based Buffer Overflow, Untrusted Pointer Dereference, and Out-of-bounds Read vulnerabilities in Siemens JT2Go and Teamcenter Visualization software products.
Titel
Siemens Solid Edge
Veröffentlicht
12. Januar 2021 16:40
Text
This advisory contains mitigations for Out-of-bounds Write, and Stack-based Buffer Overflow vulnerabilities in Siemens Solid Edge software tools.
Titel
Siemens SCALANCE X Products
Veröffentlicht
12. Januar 2021 16:35
Text
This advisory contains mitigations for Missing Authentication for Critical Function, and Heap-based Buffer Overflow vulnerabilities in Siemens SCALANCE X switches.
Titel
Siemens Opcenter Execution Core (Update B)
Veröffentlicht
12. Januar 2021 16:30
Text
This updated advisory is a follow-up to the original advisory titled ICSA-20-196-07 Siemens Opcenter Execution Core (Update A) that was published August 11, 2020, to the ICS webpage on us-cert.cisa.gov. This advisory contains mitigations for Cross-site Scripting, SQL Injection, and Improper Access Control vulnerabilities in Siemens Opcenter Execution Core software.
Titel
Siemens SIMATIC, SINAMICS, SINEC, SINEMA, SINUMERIK (Update E)
Veröffentlicht
12. Januar 2021 16:25
Text
This updated advisory is a follow-up to the advisory update titled ICSA-20-161-04 Siemens SIMATIC, SINAMICS, SINEC, SINEMA, SINUMERIK (Update D) that was published December 8, 2020, to the ICS webpage on us-cert.cisa.gov. This advisory contains mitigations for an Unquoted Search Path or Element vulnerability in Siemens SIMATIC, SINAMICS, SINEC, SINEMA, ...
Titel
Siemens SIMOTICS, Desigo, APOGEE, and TALON (Update A)
Veröffentlicht
12. Januar 2021 16:20
Text
This updated advisory is a follow-up to the original advisory titled ICSA-20-105-06 Siemens SIMOTICS, Desigo, APOGEE, and TALON that was published April 14, 2020, to the ICS webpage on us-cert.cisa.gov. This advisory contains mitigations for a business logic errors vulnerability in Siemens SIMOTICS, Desigo, APOGEE, and TALON products.
Titel
Siemens SCALANCE & SIMATIC (Update C)
Veröffentlicht
12. Januar 2021 16:15
Text
This updated advisory is a follow-up to the advisory update titled ICSA-20-105-07 Siemens SCALANCE & SIMATIC (Update B) that was published September 8, 2020, to the ICS webpage on us-cert.cisa.gov. This advisory contains mitigations for a resource exhaustion vulnerability in Siemens SCALANCE and SIMATIC products.
Titel
SSA-162506 V1.1 (Last Update: 2021-01-12): DHCP Client Vulnerability in SIMOTICS CONNECT 400, Desigo PXC/PXM, APOGEE MEC/MBC/PXC, APOGEE PXC Series, and TALON TC Series
Veröffentlicht
12. Januar 2021 01:00
Text
SIMOTICS CONNECT 400, Desigo (Power PC-based), APOGEE MEC/MBC/PXC and TALON TC products are affected by a DHCP Client vulnerability as initially reported in SSA-434032 for the Mentor Nucleus Networking Module. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for ...
Titel
SSA-102233 V1.4 (Last Update: 2021-01-12): SegmentSmack in VxWorks-based Industrial Devices
Veröffentlicht
12. Januar 2021 01:00
Text
The products listed below contain a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens is working on software ...
Titel
SSA-604937 V1.2 (Last Update: 2021-01-12): Multiple Web Server Vulnerabilities in Opcenter Execution Core
Veröffentlicht
12. Januar 2021 01:00
Text
Opcenter Execution Core (formerly known as Camstar Enterprise Platform) contains a cross-site scripting (CVE-2020-7576), an SQL injection (CVE-2020-7577), a privilege escalation (CVE-2020-7578), and an information disclosure vulnerability (CVE-2020-28930) in various versions of the product. Siemens has released an update for Opcenter Execution Core and recommends to update to the latest ...
Titel
SSA-629512 V1.2 (Last Update: 2021-01-12): Local Privilege Escalation Vulnerability in TIA Portal
Veröffentlicht
12. Januar 2021 01:00
Text
The latest updates for TIA Portal fix a vulnerability that could allow a local attacker to execute arbitrary code with SYSTEM privileges. Siemens has released updates for the affected products and recommends to update to the latest version(s).
Titel
SSA-455843 V1.3 (Last Update: 2021-01-12): WIBU Systems CodeMeter Runtime Vulnerabilities in Siemens and Siemens Energy Products
Veröffentlicht
12. Januar 2021 01:00
Text
CISA and WIBU Systems disclosed six vulnerabilities in different versions of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens and Siemens Energy products for license management. The vulnerabilities are described in the section “Vulnerability Classification” below and got assigned the CVE IDs CVE-2020-14509, CVE-2020-14513, CVE-2020-14515, ...
Titel
SSA-312271 V1.5 (Last Update: 2021-01-12): Unquoted Search Path Vulnerabilities in Windows-based Industrial Software Applications
Veröffentlicht
12. Januar 2021 01:00
Text
The latest update for affected products fix local privilege escalation vulnerabilities that could allow authorized local users with administrative privileges to execute custom code with SYSTEM level privileges. Siemens has released updates for some of the affected products, and is working on further updates. For the remaining affected products, Siemens ...
Titel
SSA-270778 V1.6 (Last Update: 2021-01-12): Denial-of-Service Vulnerability in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC Software
Veröffentlicht
12. Januar 2021 01:00
Text
A Denial-of-Service vulnerability was found in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC software when encrypted communication is enabled. The vulnerability could allow an attacker with network access to cause a Denial-of-Service condition under certain circumstances (versions prior to SIMATIC WinCC V7.3 or SIMATIC PCS 7 V8.1 are ...
Titel
SSA-139628 V1.0: Vulnerabilities in Web Server for Scalance X Products
Veröffentlicht
12. Januar 2021 01:00
Text
Several SCALANCE X switches contain vulnerabilities in the web server of the affected devices. An unauthenticated attacker could reboot, cause denial-of-service conditions and potentially impact the system by other means through heap and buffer overflow vulnerabilities. Siemens has released updates for several affected products and recommends to update to the ...