Dezember 2020
Titel
SSA-181018 V1.6 (Last Update: 2020-12-08): Heap Overflow Vulnerability in SCALANCE X switches, RUGGEDCOM Win, RFID 181EIP, and SIMATIC RF182C
Veröffentlicht
8. Dezember 2020 01:00
Text
SCALANCE X switches, RUGGEDCOM Win, RFID 181EIP, and SIMATIC RF182C are affected by a vulnerability that could allow an unprivileged attacker located in the same local network segment (OSI Layer 2) to gain system privileges by sending a specially crafted DHCP response to a client’s DHCP request. Siemens has released ...
Titel
SSA-102233 V1.3 (Last Update: 2020-12-08): SegmentSmack in VxWorks-based Industrial Devices
Veröffentlicht
8. Dezember 2020 01:00
Text
The products listed below contain a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens is working on software ...
Titel
SSA-102144 V1.1 (Last Update: 2020-12-08): Code Execution Vulnerability in LOGO! Soft Comfort
Veröffentlicht
8. Dezember 2020 01:00
Text
A vulnerability was identified in LOGO! Soft Comfort. The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project. Siemens has released an update for the LOGO! Soft Comfort and recommends that customers update to the latest version.
Titel
SSA-87240 V1.2 (Last Update: 2020-12-08): Vulnerabilities in SIEMENS LOGO!
Veröffentlicht
8. Dezember 2020 01:00
Text
Two vulnerabilities have been identified in SIEMENS LOGO!8 BM devices. The most severe vulnerability could allow an attacker to hijack existing web sessions. Siemens has released updates for the affected products and recommends that customers update to the latest version.
Titel
SSA-712690 V1.0: Vulnerabilities in XHQ Operations Intelligence
Veröffentlicht
8. Dezember 2020 01:00
Text
Multiple vulnerabilities have been identified in the XHQ Operations Intelligence product line. These vulnerabilities could allow for data injection in the XHQ’s web interfaces. Siemens recommends to update XHQ Operations Intelligence product line to the newest version.
Titel
SSA-700697 V1.0: Denial-of-Service Vulnerability in Web Server of SIMATIC Controllers
Veröffentlicht
8. Dezember 2020 01:00
Text
SIMATIC ET 200SP Open Controller V20.8 and SIMATIC S7-1500 Software Controller V20.8 are affected by a denial-of-service vulnerability in the web server. Siemens has released updates for the affected products and recommends to update to the latest version.
Titel
SSA-541017 V1.0: Embedded TCP/IP Stack Vulnerabilities (AMNESIA:33) in SIRIUS 3RW5 Modbus TCP and SENTRON PAC Devices
Veröffentlicht
8. Dezember 2020 01:00
Text
Recently security researchers discovered and disclosed 33 vulnerabilities in several open-source TCP/IP stacks for embedded devices, also known as “AMNESIA:33” vulnerabilities. The Siemens products mentioned below are affected by one of these vulnerabilities (CVE-2020-13988). Siemens has released updates for SENTRON PAC devices, is working on updates for SIRIUS 3RW5 communication ...
Titel
SSA-478893 V1.0: TightVNC Vulnerabilities in Industrial Products
Veröffentlicht
8. Dezember 2020 01:00
Text
Multiple TightVNC (V1.x) vulnerabilities in the affected products could allow remote code execution and Denial-of-Service attacks under certain conditions. Siemens has released updates for several affected products, is working on updates for the remaining affected products and recommends specific countermeasures until fixes are available.
Titel
SSA-415783 V1.0: Insecure SSL configuration in SICAM A8000 CP-8000, CP-8021 and CP-8022
Veröffentlicht
8. Dezember 2020 01:00
Text
Some firmware versions of the affected products use outdated and insecure ciphers or can be downgraded to use outdated and insecure ciphers.
Titel
SSA-087240 V1.2 (Last Update: 2020-12-08): Vulnerabilities in SIEMENS LOGO!
Veröffentlicht
8. Dezember 2020 01:00
Text
Two vulnerabilities have been identified in SIEMENS LOGO!8 BM devices. The most severe vulnerability could allow an attacker to hijack existing web sessions. Siemens has released updates for the affected products and recommends that customers update to the latest version.
Titel
AA20-336A: Advanced Persistent Threat Actors Targeting U.S. Think Tanks
Veröffentlicht
1. Dezember 2020 19:00
Text
Original release date: December 1, 2020

Summary

This Advisory uses the MITRE Adversarial Tactics, Techniques, and Common Knowledge (ATT&CK®) framework. See the ATT&CK for Enterprise for all referenced threat actor tactics and techniques.

The Cybersecurity and Infrastructure Security Agency (CISA) and the Federal Bureau of Investigation (FBI) have ...

Titel
Schneider Electric EcoStruxure Operator Terminal Expert runtime (Vijeo XD)
Veröffentlicht
1. Dezember 2020 16:00
Text
This advisory contains mitigations for an Improper Privilege Management vulnerability in Schneider Electric EcoStruxure Operator Terminal Expert products.
November 2020
Titel
Rockwell Automation FactoryTalk Linx
Veröffentlicht
24. November 2020 16:05
Text
This advisory contains mitigations for Improper Input Validation, and Heap-based Buffer Overflow vulnerabilities in Rockwell Automation FactoryTalk Linx software.
Titel
Mitsubishi Electric MELSEC iQ-R Series
Veröffentlicht
19. November 2020 16:00
Text
This advisory contains mitigations for an Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric's MELSEC iQ-R series CPU module products.
Titel
Johnson Controls Sensormatic Electronics American Dynamics victor Web Client
Veröffentlicht
17. November 2020 16:15
Text
This advisory contains mitigations for an Improper Authorization vulnerability in Sensormatic Electronics (a subsidiary of Johnson Controls) American Dynamics victor Web Client products.
Titel
Paradox IP150
Veröffentlicht
17. November 2020 16:10
Text
This advisory contains mitigations for Stack-based Buffer Overflow, and Classic Buffer Overflow vulnerabilities in Paradox IP150 Internet module LAN devices.
Titel
Real Time Automation EtherNet/IP
Veröffentlicht
17. November 2020 16:05
Text
This advisory contains mitigations for a Stack-based Buffer Overflow vulnerability in Real Time Automation 499ES EtherNet/IP Adaptor Source Code, a TCP/IP stack.
Titel
Schneider Electric Interactive Graphical SCADA System (IGSS)
Veröffentlicht
17. November 2020 16:00
Text
This advisory contains mitigations for Improper Restriction of Operations within the Bounds of a Memory Buffer, Out-of-bounds Write, and Out-of-bounds Read vulnerabilities in Schneider Electric's Interactive Graphical SCADA System (IGSS).
Titel
BD Alaris 8015 PC Unit and BD Alaris Systems Manager
Veröffentlicht
12. November 2020 16:05
Text
This advisory contains mitigations for an Improper Authentication vulnerability in BD Alaris 8015 PC Unit and BD Alaris Systems Manager. BD Alaris is an infusion pump system.
Titel
SSA-455843 (Last Update: 2020-11-10): WIBU Systems CodeMeter Runtime Vulnerabilities in Siemens and Siemens Energy Products
Veröffentlicht
10. November 2020 01:00
Text
CISA and WIBU Systems disclosed six vulnerabilities in different versions of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens and Siemens Energy products for license management. The vulnerabilities are described in the section “Vulnerability Classification” below and got assigned the CVE IDs CVE-2020-14509, CVE-2020-14513, CVE-2020-14515, ...
Titel
SSA-381684 (Last Update: 2020-11-10): Improper Password Protection during Authentication in SIMATIC S7-300 and S7-400 CPUs and Derived Products
Veröffentlicht
10. November 2020 01:00
Text
A vulnerability has been identified in SIMATIC S7-300 and S7-400 CPU families and derived products, which could result in credential disclosure. Siemens recommends countermeasures as there are currently no fixes available.
Titel
SSA-492828 (Last Update: 2020-11-10): Denial-of-Service Vulnerability in SIMATIC S7-300 CPUs and SINUMERIK Controller
Veröffentlicht
10. November 2020 01:00
Text
A vulnerability in S7-300 might allow an attacker to cause a Denial-of-Service condition on port 102 of the affected devices by sending specially crafted packets. Siemens is preparing updates and recommends specific countermeasures until fixes are available.
Titel
SSA-431802 (Last Update: 2020-11-10): Multiple Vulnerabilities in SCALANCE W1750D
Veröffentlicht
10. November 2020 01:00
Text
Siemens SCALANCE W1750D is a brandlabled device. Aruba has released a related security advisory (ARUBA-PSA-2016-004) [0] disclosing vulnerabilities in its Aruba Instant product line. The advisory contains multiple related vulnerabilities that are summarized in CVE-2016-2031. This advisory is a reminder to customers that the PAPI protocol is not a secure ...
Titel
SSB-439005 (Last Update: 2020-11-10): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Veröffentlicht
10. November 2020 01:00
Text
Titel
SSA-841348 (Last Update: 2020-11-10): Multiple Vulnerabilities in the UMC Stack
Veröffentlicht
10. November 2020 01:00
Text
The latest update for the below listed products fixes two security vulnerabilities that could allow an attacker to cause a partial Denial-of-Service on the UMC component of the affected devices under certain circumstances, and one vulnerability that could allow an attacker to locally escalate privileges from a user with administrative ...

Letzte Updates

BOSCH PSIRT
20.03.2024
CODESYS
28.06.2023
SIEMENS CERT
19.04.2024
US CERT
17.04.2024
US CERT (ICS)
18.04.2024

Nach Quelle

Archiv

2024
2023
2022
2021
2020
2019
2018
2017

Feeds