Mai 2020
Titel
AA20-126A: APT Groups Target Healthcare and Essential Services
Veröffentlicht
5. Mai 2020 14:58
Text
Original release date: May 5, 2020SummaryThis is a joint alert from the United States Department of Homeland Security (DHS) Cybersecurity and Infrastructure Security Agency (CISA) and the United Kingdom’s National Cyber Security Centre (NCSC). CISA and NCSC continue to see indications that advanced persistent threat (APT) groups are exploiting the ...
April 2020
Titel
AA20-120A: Microsoft Office 365 Security Recommendations
Veröffentlicht
29. April 2020 16:41
Text
Original release date: April 29, 2020SummaryAs organizations adapt or change their enterprise collaboration capabilities to meet “telework” requirements, many organizations are migrating to Microsoft Office 365 (O365) and other cloud collaboration services. Due to the speed of these deployments, organizations may not be fully considering the security configurations of these ...
Titel
LCDS LAquis SCADA
Veröffentlicht
28. April 2020 16:00
Text
This advisory contains mitigations for exposure of sensitive information to an unauthorized actor, and improper input validation vulnerabilities in LCDS's LAquis SCADA software.
Titel
Sierra Wireless AirLink ALEOS (Update B)
Veröffentlicht
23. April 2020 16:00
Text
This updated advisory is a follow-up to the original advisory titled ICSA-19-122-03 Sierra Wireless AirLink ALEOS (Update A) that was published August 20, 2019, to the ICS webpage on us-cert.gov. This updated advisory includes mitigations for OS command injection, use of hard-coded credentials, unrestricted upload of file with dangerous type, ...
Titel
Inductive Automation Ignition
Veröffentlicht
21. April 2020 16:00
Text
This advisory contains mitigations for an improper access control vulnerability in Inductive Automation's Ignition 8 Gateway web server software.
Titel
AA20-107A: Continued Threat Actor Exploitation Post Pulse Secure VPN Patching
Veröffentlicht
16. April 2020 15:21
Text
Original release date: April 16, 2020 | Last revised: June 30, 2020SummaryNote: This Activity Alert uses the MITRE Adversarial Tactics, Techniques, and Common Knowledge (ATT&CK®) framework. See the ATT&CK for Enterprise framework for all referenced threat actor techniques and mitigations. This Alert provides an update to Cybersecurity and Infrastructure Security ...
Titel
AA20-106A: Guidance on the North Korean Cyber Threat
Veröffentlicht
15. April 2020 14:31
Text
Original release date: April 15, 2020 | Last revised: June 23, 2020SummaryThe U.S. Departments of State, the Treasury, and Homeland Security, and the Federal Bureau of Investigation are issuing this advisory as a comprehensive resource on the North Korean cyber threat for the international community, network defenders, and the public. ...
Titel
Eaton HMiSoft VU3
Veröffentlicht
14. April 2020 17:05
Text
This advisory contains mitigations for stack-based buffer overflow and out-of-bounds read vulnerabilities in Eaton's HMiSoft VU3 human-machine interface (HMI).
Titel
Triangle MicroWorks DNP3 Outstation Libraries
Veröffentlicht
14. April 2020 17:00
Text
This advisory contains mitigations for a stack-based buffer overflow vulnerability in Triangle MicroWorks DNP3 components and source code libraries.
Titel
Triangle MicroWorks SCADA Data Gateway
Veröffentlicht
14. April 2020 16:55
Text
This advisory contains mitigations for stack-based buffer overflow, out-of-bounds read, and type confusion vulnerabilities in the Triangle MicroWorks SCADA Data Gateway.
Titel
Siemens Climatix
Veröffentlicht
14. April 2020 16:50
Text
This advisory contains mitigations for cross-site scripting and basic XSS vulnerabilities in Siemens Climatix controllers.
Titel
Siemens IE/PB-Link, RUGGEDCOM, SCALANCE, SIMATIC, SINEMA
Veröffentlicht
14. April 2020 16:45
Text
This advisory contains mitigations for uncontrolled resource consumption and improper input validation vulnerabilities in Siemens IE/PB-Link, RUGGEDCOM, SCALANCE, SIMATIC, and SINEMA products.
Titel
Siemens SIMOTICS, Desigo, APOGEE, and TALON
Veröffentlicht
14. April 2020 16:40
Text
This advisory contains mitigations for a business logic errors vulnerability in Siemens' SIMOTICS, Desigo, APOGEE, and TALON products.
Titel
Siemens SCALANCE & SIMATIC
Veröffentlicht
14. April 2020 16:35
Text
This advisory contains mitigations for a resource exhaustion vulnerability in Siemens' SCALANCE and SIMATIC products.
Titel
Siemens KTK, SIDOOR, SIMATIC, and SINAMICS
Veröffentlicht
14. April 2020 16:30
Text
This advisory contains mitigations for an uncontrolled resource consumption vulnerability in Siemens' KTN, SIDOOR, SIMATIC, and SINAMICS products.
Titel
Siemens TIM 3V-IE and 4R-IE Family Devices
Veröffentlicht
14. April 2020 16:25
Text
This advisory contains mitigations for an active debug code vulnerability in Siemens TIM 3V-IE and 4R-IE Family Devices.
Titel
Siemens SIMATIC S7 (Update B)
Veröffentlicht
14. April 2020 16:20
Text
This updated advisory is a follow-up to the advisory update titled ICSA-20-042-05 Siemens SIMATIC S7 (Update A) that was published March 10, 2020, to the ICS webpage on us-cert.gov. This advisory contains mitigations for a resource exhaustion vulnerability in Siemens SIMATIC S7 devices.
Titel
SSA-102233 (Last Update: 2020-04-14): SegmentSmack in VxWorks-based Industrial Devices
Veröffentlicht
14. April 2020 02:00
Text
The latest updates for the affected products fix a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens is ...
Titel
SSB-382508 (Last Update: 2020-04-14): ActiveX used in Industrial Products
Veröffentlicht
14. April 2020 02:00
Text
Titel
SSA-398519 (Last Update: 2020-04-14): Vulnerabilities in Intel CPUs (November 2019)
Veröffentlicht
14. April 2020 02:00
Text
Intel has published information on vulnerabilities in Intel products in November 2019. In this advisory Siemens only explicitly mentions the vulnerabilities from the "Intel® CPU Security Advisory" and one vulnerability from "Intel® CSME, Intel® SPS, Intel® TXE, Intel® AMT, Intel® PTT and Intel® DAL Advisory" and lists the Siemens IPC ...
Titel
SSA-629512 (Last Update: 2020-04-14): Local Privilege Escalation Vulnerability in TIA Portal
Veröffentlicht
14. April 2020 02:00
Text
The latest updates for TIA Portal fix a vulnerability that could allow a local attacker to execute arbitrary code with SYSTEM privileges. Siemens has released updates for TIA Portal V15 and V16, and is working on updates for TIA Portal V14. Siemens recommends specific countermeasures as there are currently no ...
Titel
SSA-473245 (Last Update: 2020-04-14): Denial-of-Service Vulnerability in Profinet Devices
Veröffentlicht
14. April 2020 02:00
Text
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of specially crafted UDP packets are sent to the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates ...
Titel
SSA-593272 (Last Update: 2020-04-14): SegmentSmack in Interniche IP-Stack based Industrial Devices
Veröffentlicht
14. April 2020 02:00
Text
A vulnerability exists in affected products that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service.
Titel
SSA-377115 (Last Update: 2020-04-14): SegmentSmack in Linux IP-Stack based Industrial Devices
Veröffentlicht
14. April 2020 02:00
Text
The latest updates for the affected products fix a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has ...
Titel
SSA-462066 (Last Update: 2020-04-14): Vulnerability known as TCP SACK PANIC in Industrial Products
Veröffentlicht
14. April 2020 02:00
Text
Multiple industrial products are affected by a vulnerability in the kernel known as TCP SACK PANIC. The vulnerability could allow a remote attacker to cause a denial of service condition. Siemens has released updates for several affected products, and recommends that customers update to the latest version. Siemens is preparing ...