• 1
  • 2 (current)
Dienstag, 10.03.2020
Titel
SSA-273799 (Last Update: 2020-03-10): Vulnerability in SIMATIC products
Veröffentlicht
10. März 2020 01:00
Text
A vulnerability has been identified in several SIMATIC products. The vulnerability could allow an attacker in a Man-in-the-Middle position to modify network traffic exchanged on port 102/tcp to PLCs of the SIMATIC S7-1200, SIMATIC S7-1500 and SIMATIC SoftwareController CPU families. Siemens has released updates for several affected products, and recommends ...
Titel
SSA-307392 (Last Update: 2020-03-10): Denial-of-Service in OPC UA in Industrial Products
Veröffentlicht
10. März 2020 01:00
Text
A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a Denial-of-Service condition on the service or the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and ...
Titel
SSA-616472 (Last Update: 2020-03-10): ZombieLoad and Microarchitectural Data Sampling Vulnerabilities in Industrial Products
Veröffentlicht
10. März 2020 01:00
Text
Security researchers published information on vulnerabilities known as ZombieLoad and Microarchitectural Data Sampling (MDS). These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerabilities.
Titel
SSA-780073 (Last Update: 2020-03-10): Denial-of-Service Vulnerability in PROFINET Devices via DCE-RPC Packets
Veröffentlicht
10. März 2020 01:00
Text
Products that include the Siemens PROFINET-IO (PNIO) stack in versions prior V06.00 are potentially affected by a denial-of-service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is ...
Titel
SSA-232418 (Last Update: 2020-03-10): Vulnerabilities in SIMATIC S7-1200 and SIMATIC S7-1500 CPU families
Veröffentlicht
10. März 2020 01:00
Text
Two vulnerabilities have been identified in the SIMATIC S7-1200 and S7-1500 CPU families. One vulnerability could allow an attacker with network access to affected devices to modify the user program stored on these devices such that the source code differs from the actual running code. The other vulnerability could allow ...
Titel
SSA-844761 (Last Update: 2020-03-10): Multiple Vulnerabilities in CCS, FTP and Streaming Services of SiNVR Video Management Solution
Veröffentlicht
10. März 2020 01:00
Text
SiNVR V3 contains several vulnerabilities in the components Central Control Server (CCS), as well as in the FTP and streaming services of the Video Server. The vulnerabilities involve path traversal (CVE-2019-19290, CVE-2019-19296, CVE-2019-19297), information disclosure (CVE-2019-19291, CVE-2019-19299), SQL injection (CVE-2019-19292), cross-site scripting (CVE-2019-19293, CVE-2019-19294), insufficient logging (CVE-2019-19295), and denial-of-service (CVE-2019-19298). ...
Titel
SSA-508982 (Last Update: 2020-03-10): Denial-of-Service Vulnerability in SIMATIC S7-300 CPUs and SINUMERIK Controller over Profinet
Veröffentlicht
10. März 2020 01:00
Text
The latest firmware update for the S7-300 CPUs fixes a vulnerability that could allow an unauthenticated attacker with network access to cause a denial-of-service condition. SINUMERIK 840D sl Controller, which contains a S7-300 CPU, is also affected. Siemens is preparing further updates and recommends specific countermeasures until patches are available.
Titel
SSA-270778 (Last Update: 2020-03-10): Denial-of-Service Vulnerability in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC Software
Veröffentlicht
10. März 2020 01:00
Text
A Denial-of-Service vulnerability was found in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC software when encrypted communication is enabled. The vulnerability could allow an attacker with network access to cause a Denial-of-Service condition under certain circumstances (versions prior to SIMATIC WinCC V7.3 or SIMATIC PCS 7 V8.1 are ...
Titel
SSA-938930 (Last Update: 2020-03-10): Cross-Site Scripting Vulnerability in Spectrum Power™ 5
Veröffentlicht
10. März 2020 01:00
Text
A Cross-Site Scripting (XSS) vulnerability was found in the Engineering User Interface of Spectrum Power™ 5. A software update is available to address the issue and Siemens recommends installing the patch.
Titel
SSA-480230 (Last Update: 2020-03-10): Denial-of-Service in Webserver of Industrial Products
Veröffentlicht
10. März 2020 01:00
Text
A vulnerability in the affected devices could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends ...
Titel
SSA-473245 (Last Update: 2020-03-10): Denial-of-Service Vulnerability in Profinet Devices
Veröffentlicht
10. März 2020 01:00
Text
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of specially crafted UDP packets are sent to the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates ...
Titel
SSA-750824 (Last Update: 2020-03-10): Denial-of-Service Vulnerability in Profinet Devices
Veröffentlicht
10. März 2020 01:00
Text
SIMATIC S7-1500 CPU family devices are affected by a vulnerability that could allow an attacker to perform a Denial-of-Service attack if specially crafted UDP packets are sent to the device. Siemens has released updates for the affected products and recommends that customers update to these new versions.
Titel
SSA-398519 (Last Update: 2020-03-10): Vulnerabilities in Intel CPUs (November 2019)
Veröffentlicht
10. März 2020 01:00
Text
Intel has published information on vulnerabilities in Intel products in November 2019. In this advisory Siemens only explicitly mentions the vulnerabilities from the "Intel® CPU Security Advisory" and one vulnerability from "Intel® CSME, Intel® SPS, Intel® TXE, Intel® AMT, Intel® PTT and Intel® DAL Advisory" and lists the Siemens IPC ...
Titel
SSA-451445 (Last Update: 2020-03-10): Multiple Vulnerabilities in SPPA-T3000
Veröffentlicht
10. März 2020 01:00
Text
SPPA-T3000 Application Server and MS3000 Migration Server are affected by multiple vulnerabilities. Some of the vulnerabilities can allow an attacker to execute arbitrary code on the server. Exploitation of the vulnerabilities described in this advisory requires access to either Application- or Automation Highway. Both highways should not be exposed if ...
Titel
SSA-731239 (Last Update: 2020-03-10): Vulnerabilities in SIMATIC S7-300 and S7-400 CPUs
Veröffentlicht
10. März 2020 01:00
Text
Two vulnerabilities have been identified in SIMATIC S7-300 and S7-400 CPU families. One vulnerability could lead to a Denial-of-Service, the other vulnerability could result in credential disclosure. Siemens recommends specific mitigations. Siemens will update this advisory when new information becomes available.
Donnerstag, 05.03.2020
Titel
WAGO I/O-CHECK
Veröffentlicht
5. März 2020 16:00
Text
This advisory contains mitigations for information exposure through sent data, buffer access with incorrect length value, missing authentication for critical function, and classic buffer overflow vulnerabilities in the WAGO I/O CHECK software.
Dienstag, 03.03.2020
Titel
SweynTooth Vulnerabilities
Veröffentlicht
3. März 2020 16:20
Text
This ALERT details vulnerabilities in SweynTooth's Bluetooth Low Energy (BLE) proof-of-concept (PoC) exploit code. This report was released without coordination with some of the affected vendors and without advance coordination with CISA. CISA has notified some of the affected vendors of the report and has asked the vendors to confirm ...
Titel
Emerson ValveLink
Veröffentlicht
3. März 2020 16:15
Text
This advisory contains mitigations for an improper access control vulnerability in Emerson's ValveLink digital valve controllers.
Titel
PHOENIX CONTACT Emalytics Controller ILC
Veröffentlicht
3. März 2020 16:10
Text
This advisory contains mitigations for an incorrect permission assignment for critical resource vulnerability in Phoenix Contact's Emalytics Controller modular inline devices.
Titel
Omron PLC CJ Series
Veröffentlicht
3. März 2020 16:05
Text
This advisory contains mitigations for an uncontrolled resource consumption vulnerability in Omron's PLC CJ Series programmable logic controllers.
Titel
Moxa AWK-3131A Series Industrial AP/Bridge/Client
Veröffentlicht
3. März 2020 16:00
Text
This advisory contains mitigations for several vulnerabilities in Moxa's AWK-3131A wireless networking appliance.