Bulletins

SIEMENS CERT
11/13/2018
The latest update for SIMATIC STEP7 (TIA Portal) fixes a vulnerability that could allow an attacker with local access to a project file to reconstruct certain passwords stored in the project. Siemens recommends to update to the new version.
SIEMENS CERT
11/13/2018
A vulnerability was identified in SIMATIC S7-1200 and S7-1500 CPUs that could allow an attacker to cause a denial-of-service condition preventing HMI or engineering access to the PLC over port 102/tcp. Siemens has released an update for the S7-1500 product and recommends that customers update to the new version. Siemens …
SIEMENS CERT
11/13/2018
A Cross-Site Scripting (XSS) vulnerability was found in the web server of SCALANCE S firewalls. Siemens provides firmware version V4.0.1.1, which fixes the vulnerability and recommends to update to the newest version.
SIEMENS CERT
11/13/2018
The latest update for SIMATIC Panel software and SIMATIC WinCC (TIA Portal) fixes two web vulnerabilities. The most severe is a vulnerability which could allow an attacker with network access to the integrated webserver to download arbitrary files. Siemens recommends to update to the newest version.
SIEMENS CERT
11/13/2018
Two vulnerabilities have been identified in the SIMATIC S7-400 CPU family that could allow an attacker to cause a Denial-of-Service condition. In order to exploit the vulnerability, an attacker must have access to the affected devices on port 102/tcp via Ethernet, PROFIBUS or Multi Point Interfaces (MPI). Siemens provides updates …
SIEMENS CERT
10/09/2018
The latest update for SCALANCE W1750D addresses a vulnerability known as ROBOT Attack. The vulnerability could allow an attacker to decrypt TLS traffic. Siemens provides a firmware update and recommends users to update to the new version.
SIEMENS CERT
10/09/2018
Several industrial controllers are affected by a security vulnerability that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct OSI Layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released …
SIEMENS CERT
10/09/2018
The latest updates for SIMATIC STEP 7 (TIA Portal) and SIMATIC WinCC (TIA Portal) fix two vulnerabilities. These two vulnerabilities could either allow an attacker with local file write access to manipulate files and cause a Denial-of-service-condition, or execute code both on the manipulated installation and on devices that are …