Multiple NULL pointer dereference vulnerabilities in the affected products could allow an attacker with network access to the webserver, to perform a denial of service attack. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where …
SIEMENS CERT
09/10/2024
Siemens Tecnomatix Plant Simulation is affected by a stack-based buffer overflow vulnerability that could be triggered when the application reads files in SPP file format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially …
SIEMENS CERT
09/10/2024
An OpenSSH vulnerability, known as regreSSHion, affects multiple Siemens industrial products. This security regression vulnerability consists in a race condition which may allow an unauthenticated remote attacker to achieve remote code execution with high impact on the affected system. Siemens has released new versions for several affected products and recommends …
SIEMENS CERT
09/10/2024
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens has released a new version of Palo Alto Networks Virtual NGFW for RUGGEDCOM APE1808 and recommends to update to the latest version. Customers are advised to …
SIEMENS CERT
09/10/2024
Multiple vulnerabilities in the affected products could allow an unauthorized attacker with network access to the webserver of an affected products to perform a denial of service attack. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
09/10/2024
The products listed below contain a remote code execution vulnerability that could allow an unauthenticated remote attacker to execute arbitrary code with high privileges. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures …
SIEMENS CERT
09/10/2024
Multiple SICAM products are affected by buffer overflow vulnerability in the IEC 61850 Client libraries from Triangle MicroWorks that could allow an unauthenticated remote attacker to create a denial of service condition by sending specially crafted MMS messages. Affected SICAM and SITIPE products: SICAM A8000 Device firmware ETI5 for CP-8031/CP-8050 …
SIEMENS CERT
09/10/2024
A vulnerability was identified in OPC Foundation Local Discovery Server which also affects Siemens products that could allow an attacker to escalate privileges under certain circumstances. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where …