Mai 2024
Titel
Siemens SICAM Products
Veröffentlicht
16. Mai 2024 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Titel
Siemens PS/IGES Parasolid Translator Component
Veröffentlicht
16. Mai 2024 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Titel
Rockwell Automation FactoryTalk View SE
Veröffentlicht
16. Mai 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk View SE Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to inject a malicious SQL statement in the SQL database, resulting in expose sensitive ...
Titel
Siemens Desigo Fire Safety UL and Cerberus PRO UL Fire Protection Systems
Veröffentlicht
16. Mai 2024 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Titel
Siemens SIMATIC CN 4100 Before V3.0
Veröffentlicht
16. Mai 2024 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Titel
Siemens Simcenter Nastran
Veröffentlicht
16. Mai 2024 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Titel
SUBNET PowerSYSTEM Center and Substation Server
Veröffentlicht
14. Mai 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION: Low attack complexity Vendor: Subnet Solutions Inc. Equipment: PowerSYSTEM Center Vulnerabilities: Reliance on Insufficiently Trustworthy Component 2. RISK EVALUATION Successful exploitation of the vulnerabilities in components used by PowerSYSTEM Center could allow privilege escalation, denial-of-service, or arbitrary code execution. 3. TECHNICAL ...
Titel
Johnson Controls Software House C-CURE 9000
Veröffentlicht
14. Mai 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.7 ATTENTION: Low attack complexity Vendor: Johnson Controls Equipment: Software House C●CURE 9000 Vulnerability: Insertion of Sensitive Information into Log File 2. RISK EVALUATION Successful exploitation of this vulnerability may allow an attacker to access credentials used for access to the application. 3. ...
Titel
Mitsubishi Electric Multiple FA Engineering Software Products
Veröffentlicht
14. Mai 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 6.0 ATTENTION: Low attack complexity Vendor: Mitsubishi Electric Equipment: Multiple FA Engineering Software Products Vulnerabilities: Improper Privilege Management, Uncontrolled Resource Consumption, Out-of-bounds Write, Improper Privilege Management 2. RISK EVALUATION Successful exploitation of these vulnerabilities may allow a local attacker to cause a Windows ...
Titel
Rockwell Automation FactoryTalk Remote Access
Veröffentlicht
14. Mai 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.0 ATTENTION: Low attack complexity Vendor: Rockwell Automation Equipment: Factory Talk Remote Access Vulnerability: Unquoted Search Path or Element 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to enter a malicious executable and run it as a system user, ...
Titel
Rockwell Automation FactoryTalk Historian SE
Veröffentlicht
9. Mai 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk Historian SE Vulnerabilities: Missing Release of Resource after Effective Lifetime, Improper Check or Handling of Exceptional Conditions 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause a ...
Titel
alpitronic Hypercharger EV Charger
Veröffentlicht
9. Mai 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.3 ATTENTION: Exploitable remotely/Low attack complexity Vendor: alpitronic Equipment: Hypercharger EV charger Vulnerability: Use of Default Credentials 2. RISK EVALUATION Successful exploitation of this vulnerability could result in an attacker disabling the device, bypassing payment, or accessing payment data. 3. TECHNICAL DETAILS 3.1 ...
Titel
PTC Codebeamer
Veröffentlicht
7. Mai 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: PTC Equipment: Codebeamer Vulnerability: Cross-site Scripting 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to inject malicious code in the application. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of PTC ...
Titel
SUBNET Substation Server
Veröffentlicht
7. Mai 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION: Low attack complexity Vendor: Subnet Solutions Inc. Equipment: Substation Server Vulnerabilities: Reliance on Insufficiently Trustworthy Component 2. RISK EVALUATION Successful exploitation of the vulnerabilities in components used by Substation Server could allow privilege escalation, denial-of-service, or arbitrary code execution. 3. TECHNICAL ...
Titel
CyberPower PowerPanel
Veröffentlicht
2. Mai 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/Low attack complexity Vendor: CyberPower Equipment: PowerPanel Vulnerabilities: Use of Hard-coded Password, Relative Path Traversal, Use of Hard-coded Credentials, Active Debug Code, Storing Passwords in a Recoverable Format, Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'), ...
Titel
CyberPower PowerPanel business
Veröffentlicht
2. Mai 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/Low attack complexity Vendor: CyberPower Equipment: PowerPanel business Vulnerabilities: Use of Hard-coded Password, Relative Path Traversal, Use of Hard-coded Credentials, Active Debug Code, Storing Passwords in a Recoverable Format, Improper Neutralization of Special Elements used in an SQL Command ('SQL ...
April 2024
Titel
Delta Electronics CNCSoft-G2 DOPSoft
Veröffentlicht
30. April 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION: Low attack complexity Vendor: Delta Electronics Equipment: CNCSoft-G2 DOPSoft Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Delta Electronics ...
Titel
Honeywell Experion PKS, Experion LX, PlantCruise by Experion, Safety Manager, Safety Manager SC
Veröffentlicht
25. April 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Honeywell Equipment: Experion PKS, Experion LX, PlantCruise by Experion, Safety Manager, Safety Manager SC Vulnerabilities: Exposed Dangerous Method or Function, Absolute Path Traversal, Stack-based Buffer Overflow, Debug Messages Revealing Unnecessary Information, Out-of-bounds Write, Heap-based Buffer Overflow, ...
Titel
Hitachi Energy MACH SCM
Veröffentlicht
25. April 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.9 ATTENTION: Exploitable remotely Vendor: Hitachi Energy Equipment: MACH SCM Vulnerabilities: Improper Control of Generation of Code, Improper Neutralization of Directives in Dynamically Evaluated Code 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in an execution of arbitrary code. 3. TECHNICAL ...
Titel
Siemens RUGGEDCOM APE1808 Devices Configured with Palo Alto Networks Virtual NGFW
Veröffentlicht
25. April 2024 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Titel
Multiple Vulnerabilities in Hitachi Energy RTU500 Series
Veröffentlicht
25. April 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: RTU500 Series Vulnerabilities: Unrestricted Upload of File with Dangerous Type 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow the attacker to upload or transfer files of dangerous types that can be ...
Titel
Unitronics Vision Legacy Series (Update A)
Veröffentlicht
18. April 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Unitronics Equipment: Vision Legacy series Vulnerability: Storing Passwords in a Recoverable Format 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to log in to the Remote HMI feature, where the PLC may ...
Titel
Unitronics Vision Legacy series
Veröffentlicht
18. April 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Unitronics Equipment: Vision Legacy series Vulnerability: Storing Passwords in a Recoverable Format 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to log in to the Remote HMI feature, where the PLC may ...
Titel
Unitronics Vision Series PLCs
Veröffentlicht
18. April 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Unitronics Equipment: Vision series PLCs Vulnerability: Storing Passwords in a Recoverable Format 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to log in to the Remote HMI feature, where the PLC may ...
Titel
RoboDK RoboDK
Veröffentlicht
16. April 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 3.3 ATTENTION: Low attack complexity Vendor: RoboDK Equipment: RoboDK Vulnerability: Heap-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could result in an attacker crashing the program through heap-based buffer overflow. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of ...

Letzte Updates

BOSCH PSIRT
15.05.2024
SIEMENS CERT
14.05.2024
US CERT
10.05.2024
US CERT (ICS)
16.05.2024

Nach Quelle

Archiv

2024
2023
2022
2021
2020
2019
2018
2017

Feeds