SIEMENS CERT
08/12/2025
RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains multiple vulnerabilities in the integrated SQLite component that could allow an attacker to execute arbitrary code or to create a denial of service condition. Siemens has released a new version for RUGGEDCOM CROSSBOW Station Access Controller (SAC) and recommends to update to the …
SIEMENS CERT
08/12/2025
WIBU Systems published information about a privilege escalation vulnerability under a certain circumstances and associated fix releases of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens industrial products. Siemens has released new versions for affected products and recommends to update to the latest versions. Siemens …
SIEMENS CERT
08/12/2025
SIMOTION SCOUT, SIMOTION SCOUT TIA and SINAMICS STARTER are affected by an XXE injection vulnerability that could allow an attacker to access arbitrary application files. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends …
SIEMENS CERT
08/12/2025
RUGGEDCOM ROX II devices do not properly limit access through their Built-In-Self-Test (BIST) mode. This could allow a local attacker to bypass authentication and access a root shell on the device. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
US CERT
07/29/2025
Summary The Cybersecurity and Infrastructure Security Agency (CISA) and U.S. Coast Guard (USCG) are issuing this Cybersecurity Advisory to present findings from a recent CISA and USCG hunt engagement. The purpose of this advisory is to highlight identified cybersecurity issues, thereby informing security defenders in other organizations of potential similar …
CISA (ICS)
07/24/2025
1. EXECUTIVE SUMMARY CVSS v3 7.0 ATTENTION : Exploitable from a local network Vendor : Mitsubishi Electric Equipment : CNC Series Vulnerability : Uncontrolled Search Path Element 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute malicious code by getting setup-launcher to load a malicious …
CISA (ICS)
07/24/2025
1. EXECUTIVE SUMMARY CVSS v3 9.4 ATTENTION : Exploitable remotely/low attack complexity Vendor : Honeywell Equipment : Experion PKS Vulnerabilities : Use of Uninitialized Variable, Improper Restriction of Operations within the Bounds of a Memory Buffer, Sensitive Information in Resource Not Removed Before Reuse, Integer Underflow (Wrap or Wraparound), Deployment …
CISA (ICS)
07/24/2025
1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION : Exploitable remotely/low attack complexity Vendor : Network Thermostat Equipment : X-Series WiFi thermostats Vulnerability : Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to gain full administrative access to the device. 3. TECHNICAL …