März 2022
Titel
SSA-337210 V1.0: Privilege Escalation Vulnerability in SINUMERIK MC
Veröffentlicht
8. März 2022 01:00
Text
The NC plug-in card in SINUMERIK MC contains a privilege escalation vulnerability that could allow local attackers to escalate their privileges to root. This allows full access to the device, including read and modifying G code. Siemens has released updates for the affected products and recommends to update to the ...
Titel
SSA-256353 V1.0: Third-Party Component Vulnerabilities in RUGGEDCOM ROS
Veröffentlicht
8. März 2022 01:00
Text
Multiple vulnerabilities affect various third-party components of the RUGGEDCOM ROS, and a cross-site scripting exploit. If exploited, an attacker could cause a denial-of-service, act as a man-in-the-middle or retrieval of sensitive information or gain privileged functions. Siemens is preparing updates and recommends countermeasures for products where updates are not, or ...
Titel
SSA-244969 V1.2 (Last Update: 2022-03-08): OpenSSL Vulnerability in Industrial Products
Veröffentlicht
8. März 2022 01:00
Text
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1l and 1.0.2 < 1.0.2za that allows an attacker to cause a denial of service (DoS) or to disclose private memory content. Siemens has released updates for several affected products and recommends to update to ...
Titel
SSA-389290 V1.0: Third-Party Component Vulnerabilities in SINEC INS
Veröffentlicht
8. März 2022 01:00
Text
71 vulnerabilities in third-party components as Node.js, cURL, SQLite, CivetWeb and DNS(ISC BIND) could allow an attacker to interfere with the affected product in various ways. Siemens has released an update for SINEC INS and recommends to update to the latest versions.
Titel
SSA-250085 V1.0: Multiple Vulnerabilities in SINEC NMS
Veröffentlicht
8. März 2022 01:00
Text
SINEC NMS contains multiple vulnerabilities that could allow an attacker to execute arbitrary code on the system, arbitrary commands on the local database or achieve privilege escalation. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
Titel
SSA-678983 V1.3 (Last Update: 2022-03-08): Vulnerabilities in Industrial PCs and CNC devices using Intel CPUs (November 2020)
Veröffentlicht
8. März 2022 01:00
Text
Intel has published information on vulnerabilities in Intel products in November 2020. This advisory lists the Siemens IPC related products, that are affected by these vulnerabilities. In this advisory we take a representative CVE from each advisory: “Intel CSME, SPS, TXE, AMT and DAL Advisory” Intel-SA-00391 is represented by CVE-2020-8745 ...
Titel
SSA-252466 V1.0: Multiple Vulnerabilities in Climatix POL909 (AWM and AWB)
Veröffentlicht
8. März 2022 01:00
Text
Multiple vulnerabilities have been identified in the Climatix POL909 (AWM and AWB) that could allow an unauthenticated attacker to hijack and redirect users to a malicious webpage, or allow an authenticated attacker to access sensitive files. Siemens has released an update for the Climatix POL909 (AWM and AWB) and recommends ...
Titel
SSA-764417 V1.0: Multiple Vulnerabilities in RUGGEDCOM Devices
Veröffentlicht
8. März 2022 01:00
Text
There is an insecure cryptographic vulnerability for the affected RUGGEDCOM devices. If an attacker were to exploit this, they could gain privileged functions. See auto-generated summary suggestion from build
Titel
SSA-562051 V1.0: Cross-Site Scripting Vulnerability in Polarion ALM
Veröffentlicht
8. März 2022 01:00
Text
An attacker could trigger malicious actions via a cross-site scripting vulnerability by sending crafted links to an administrator user of Polarion ALM. Siemens has released an update for the Polarion Subversion Webclient and recommends to update to the latest version.
Titel
SSA-155599 V1.0: File Parsing Vulnerabilities in COMOS
Veröffentlicht
8. März 2022 01:00
Text
COMOS uses Drawings SDK from Open Design Alliance that is affected by multiple vulnerabilities that could be triggered when the application reads files in DGN, DXF or DWG file formats. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability ...
Titel
SSA-309571 V1.2 (Last Update: 2022-03-08): IPU 2021.1 Vulnerabilities in Siemens Industrial Products using Intel CPUs (June 2021)
Veröffentlicht
8. März 2022 01:00
Text
Intel has published information on vulnerabilities in Intel products in June 2021. This advisory lists the related Siemens Industrial products affected by these vulnerabilities that can be patched by applying the corresponding BIOS update. In this advisory we summarize: “2021.1 IPU – Intel® CSME, SPS and LMS Advisory” Intel-SA-00459, “2021.1 ...
Titel
SSA-166747 V1.0: Scene File Parsing Vulnerability in Simcenter STAR-CCM+ Viewer before V2022.1
Veröffentlicht
8. März 2022 01:00
Text
Siemens Simcenter STAR-CCM+ Viewer is affected by a memory corruption vulnerability that could be triggered when the application reads scene (.sce) files. If a user is tricked to open a malicious file with the affected application, this could lead to a crash, and potentially also to arbitrary code execution or ...
Titel
SSA-703715 V1.1 (Last Update: 2022-03-08): Information Disclosure Vulnerability in Climatix POL909 (AWM and AWB)
Veröffentlicht
8. März 2022 01:00
Text
Climatix POL909 (AWM and AWB) contains an information disclosure vulnerability that could allow a man-in-the-middle attacker to read sensitive data, such as administrator credentials, or modify data in transit. Siemens has released an update for Climatix POL909 (AWM and AWB) and recommends to update to the latest version.
Titel
SSA-541018 V1.5 (Last Update: 2022-03-08): Embedded TCP/IP Stack Vulnerabilities (AMNESIA:33) in SENTRON PAC / 3VA Devices (Part 2)
Veröffentlicht
8. März 2022 01:00
Text
Security researchers discovered and disclosed 33 vulnerabilities in several open-source TCP/IP stacks for embedded devices, also known as “AMNESIA:33” vulnerabilities. This advisory describes the impact of two of these vulnerabilities (CVE-2020-13987, CVE-2020-17437) to Siemens products. Siemens has released updates for several affected products and recommends to update to the latest ...
Titel
SSA-134279 V1.0: Vulnerability in Mendix Forgot Password Appstore module
Veröffentlicht
8. März 2022 01:00
Text
Mendix Forgot Password Appstore module contains two vulnerabilities that could allow unauthorized users to take over accounts. Mendix has released an update for the Mendix Forgot Password Appstore module and recommends to update to the latest version.
Titel
SSA-838121 V1.1 (Last Update: 2022-03-08): Multiple Denial of Service Vulnerabilities in Industrial Products
Veröffentlicht
8. März 2022 01:00
Text
Affected SIMATIC firmware contains three vulnerabilities that could allow an unauthenticated attacker to perform a denial-of-service attack under certain conditions. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
Titel
SSA-306654 V1.1 (Last Update: 2022-03-08): Insyde BIOS Vulnerabilities in Siemens Industrial Products
Veröffentlicht
8. März 2022 01:00
Text
Insyde has published information on vulnerabilities in Insyde BIOS in February 2022. This advisory lists the Siemens Industrial products affected by these vulnerabilities. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
Titel
SSA-223353 V1.0: Multiple Vulnerabilities in Nucleus RTOS based SIMOTICS CONNECT 400
Veröffentlicht
8. März 2022 01:00
Text
Multiple vulnerabilities (also known as “NUCLEUS:13”) have been identified in the Nucleus RTOS (real-time operating system), originally reported in the Siemens Security Advisory SSA-044112: https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf. SIMOTICS CONNECT 400 devices are affected by some of the vulnerabilities as documented below. Siemens has released an update for the SIMOTICS CONNECT 400 and ...
Titel
SSA-415938 V1.0: Improper Access Control Vulnerability in Mendix
Veröffentlicht
8. März 2022 01:00
Text
A vulnerability in Mendix Studio Pro was discovered, that, if acted upon by a malicious user, could allow to retrieve the status of a job run by another user in certain cases. Mendix has released updates for the affected product lines, recommends to update to the latest versions and to ...
Titel
SSA-148641 V1.0: XPath Constraint Vulnerability in Mendix Runtime
Veröffentlicht
8. März 2022 01:00
Text
A XPath Constraint vulnerability in the Mendix Studio Pro was discovered, that can affect the running applications. The vulnerability, if acted upon by a malicious user, could allow them the ability to dump and modify sensitive data. Mendix has released updates for the affected product lines, recommends to update to ...
Titel
SSA-594438 V1.0: Remote Code Execution and Denial-of-Service Vulnerability in multiple RUGGEDCOM ROX products
Veröffentlicht
8. März 2022 01:00
Text
A vulnerability in the RUGGEDCOM ROX devices’ third party component, NSS, could allow an attacker to remotely execute code or cause a denial-of-service condition due to the way it verifies security certificates. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-501073 V1.1 (Last Update: 2022-03-08): Vulnerabilities in Controllers CPU 1518 MFP using Intel CPUs (November 2020)
Veröffentlicht
8. März 2022 01:00
Text
Intel has published information on vulnerabilities in Intel products in November 2020. This advisory lists the Siemens Controllers that are affected by these vulnerabilities. In this advisory we take a representative CVE from each advisory: “Intel CSME, SPS, TXE, AMT and DAL Advisory” Intel-SA-00391 is represented by CVE-2020-8744 “BIOS Advisory” ...
Titel
SSA-669158 V1.1 (Last Update: 2022-03-08): DNS Client Vulnerabilities in SIMOTICS CONNECT 400
Veröffentlicht
8. März 2022 01:00
Text
SIMOTICS CONNECT 400 is affected by DNS Client vulnerabilities as initially reported in Siemens Security Advisory SSA-705111 (https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf) for the DNS Module in Nucleus RTOS. Siemens has released updates for the SIMOTICS CONNECT 400 and recommends to update to the latest version.
Titel
SSA-669737 V1.1 (Last Update: 2022-03-08): Improper Access Control Vulnerability in SICAM TOOLBOX II
Veröffentlicht
8. März 2022 01:00
Text
SICAM TOOLBOX II contains a vulnerability that could allow an attacker access through a circumventable access control. Siemens is preparing updates and recommends countermeasures for products where updates are not, or not yet available.
Titel
SSA-840188 V1.2 (Last Update: 2022-03-08): Multiple Vulnerabilities in SIMATIC WinCC Affecting Other SIMATIC Software Products
Veröffentlicht
8. März 2022 01:00
Text
Multiple vulnerabilities were found in SIMATIC WinCC that ultimately could allow local or remote attackers to escalate privileges and read, write or delete critical files. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures ...

Letzte Updates

BOSCH PSIRT
20.03.2024
CODESYS
28.06.2023
SIEMENS CERT
19.04.2024
US CERT
10.05.2024
US CERT (ICS)
09.05.2024

Nach Quelle

Archiv

2024
2023
2022
2021
2020
2019
2018
2017

Feeds