Januar 2022
Titel
SSA-661247 V2.3 (Last Update: 2022-01-17): Apache Log4j Vulnerabilities (Log4Shell, CVE-2021-44228, CVE-2021-45046) - Impact to Siemens Products
Veröffentlicht
17. Januar 2022 01:00
Text
On 2021-12-09, a vulnerability in Apache Log4j (a logging tool used in many Java-based applications) was disclosed, that could allow remote unauthenticated attackers to execute code on vulnerable systems. The vulnerability is tracked as CVE-2021-44228 and is also known as “Log4Shell”. On 2021-12-14 an additional denial of service vulnerability (CVE-2021-45046) ...
Titel
Mitsubishi Electric MELSEC-F Series
Veröffentlicht
13. Januar 2022 16:45
Text
This advisory contains mitigations for a Lack of Administrator Control Over Security vulnerability in the Mitsubishi Electric MELSEC-F Series FX3U-ENET Ethernet-Internet block.
Titel
Siemens SICAM A8000
Veröffentlicht
13. Januar 2022 16:40
Text
This advisory contains mitigations for Use of Hard-coded Credentials, and Improper Access Control vulnerabilities in Siemens SICAM A8000 remote terminal units.
Titel
Siemens Energy PLUSCONTROL
Veröffentlicht
13. Januar 2022 16:35
Text
This advisory contains mitigations for Type Confusion, Improper Validation of Specified Quantity in Input, Buffer Access with Incorrect Length Value, Integer Underflow, and Improper Handling of Inconsistent Structural Elements vulnerabilities in Siemens Energy PLUSCONTROL high-power energy transmission control devices.
Titel
Siemens SIPROTEC 5 Devices
Veröffentlicht
13. Januar 2022 16:30
Text
This advisory contains mitigations for an Improper Input Validation vulnerability in Siemens SIPROTEC 5 digital field devices.
Titel
Siemens COMOS Web
Veröffentlicht
13. Januar 2022 16:25
Text
This advisory contains mitigations for Basic XSS, Relative Path Traversal, SQL Injection, abd Cross-site Request Forgery vulnerabilities in the Siemens COMOS Web unified data platform.
Titel
Siemens SICAM PQ Analyzer
Veröffentlicht
13. Januar 2022 16:20
Text
This advisory contains mitigations for an Unquoted Search Path or Element vulnerability in the Siemens SICAM PQ Analyzer power quality system software.
Titel
Trane Symbio (Update B)
Veröffentlicht
13. Januar 2022 16:10
Text
The updated advisory is a follow-up to the advisory update titled ICSA-21-266-01 Trane Symbio (Update A) that was published on November 18, 2021, to the ICS webpage on www.cisa.gov/uscert. This advisory contains mitigations for a Code Injection vulnerability in Trane Symbio 700 and Symbio 800 controllers.
Titel
Siemens Nucleus DNS (Update A)
Veröffentlicht
13. Januar 2022 16:05
Text
This updated advisory is a follow-up to the original advisory titled ICSA-21-103-14 Siemens Nucleus DNS that was published April 13, 2021, to the ICS webpage on www.cisa.gov/uscert. This advisory contains mitigations for a Use of Insufficiently Random Values vulnerability in Siemens Nucleus industrial software products.
Titel
Mitsubishi Electric MELSEC iQ-R, Q and L Series (Update B)
Veröffentlicht
13. Januar 2022 16:00
Text
This updated advisory is a follow-up to the advisory update ICSA-20-303-01 Mitsubishi Electric MELSEC iQ-R, Q and L Series (Update A) that was published May 18, 2021, to the ICS webpage on www.cisa.gov/uscert. This advisory contains mitigations for an Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric's MELSEC iQ-R, Q and ...
Titel
Johnson Controls VideoEdge
Veröffentlicht
11. Januar 2022 16:00
Text
This advisory contains mitigations for an Improper Handling of Syntactically Invalid Structure vulnerability in the Sensormatic Electronics VideoEdge network video recorder. Sensormatic Electronics is a subsidiary of Johnson Controls.
Titel
AA22-011A: Understanding and Mitigating Russian State-Sponsored Cyber Threats to U.S. Critical Infrastructure
Veröffentlicht
11. Januar 2022 16:00
Text
Original release date: January 11, 2022SummaryActions Critical Infrastructure Organizations Should Implement to Immediately Strengthen Their Cyber Posture. • Patch all systems. Prioritize patching known exploited vulnerabilities. • Implement multi-factor authentication. • Use antivirus software. • Develop internal contact lists and surge support. Note: this advisory uses the MITRE Adversarial Tactics, ...
Titel
SSA-789208 V1.2 (Last Update: 2022-01-11): Multiple Vulnerabilities (INFRA:HALT) in Interniche IP-Stack based Low Voltage Devices
Veröffentlicht
11. Januar 2022 01:00
Text
Security researchers discovered and disclosed 14 vulnerabilities in the Interniche IP stack, also known as “INFRA:HALT” vulnerabilities [0]. This advisory describes the impact to Siemens low voltage products, which are only affected by four out of the 14 vulnerabilities. Siemens has released updates for several affected products and recommends to ...
Titel
SSA-845392 V1.0: Multiple Vulnerabilities in Nucleus RTOS based Siemens Energy PLUSCONTROL 1st Gen Devices
Veröffentlicht
11. Januar 2022 01:00
Text
Multiple vulnerabilities (also known as “NUCLEUS:13”) have been identified in the Nucleus RTOS (real-time operating system) and reported in the Siemens Security Advisory SSA-044112: https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf. PLUSCONTROL 1st Gen devices are affected by some of the vulnerabilities as documented below. Siemens Energy recommends specific countermeasures for products where updates are not ...
Titel
SSA-173318 V1.0: Unquoted Search Path Vulnerability in SICAM PQ Analyzer
Veröffentlicht
11. Januar 2022 01:00
Text
SICAM PQ Analyzer uses an unquoted registry entry and is thus vulnerable to an unquoted search path vulnerability. Siemens has released an update for the SICAM PQ Analyzer and recommends to update to the latest version.
Titel
SSA-995338 V1.0: Multiple Vulnerabilities in COMOS Web
Veröffentlicht
11. Januar 2022 01:00
Text
Multiple vulnerabilities were identified in the COMOS Web component of COMOS. They could allow an attacker to conduct code injections, store data in undesired locations, execute arbitrary SQL statements, and run cross-site-request-forgery attacks. Siemens has released an update for COMOS and recommends to update to the latest version.
Titel
SSA-766247 V1.1 (Last Update: 2022-01-11): Authentication Vulnerability in SIMATIC Process Historian
Veröffentlicht
11. Januar 2022 01:00
Text
The latest update for SIMATIC Process Historian (PH) fixes an authentication vulnerability in the configuration interface of redundant PH instances that could enable the execution of admin operations on the database. The related vulnerable interface is restricted to local access on recent versions starting from SIMATIC Process Historian 2020. Siemens ...
Titel
SSA-185699 V1.2 (Last Update: 2022-01-11): Out of Bounds Write Vulnerabilities (NAME:WRECK) in the DNS Module of Nucleus RTOS
Veröffentlicht
11. Januar 2022 01:00
Text
Security researchers discovered and disclosed 9 vulnerabilities in several DNS implementations, also known as “NAME:WRECK” vulnerabilities. The vulnerabilities described in this advisory are from this set. The DNS client of the networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) contains two out of bounds write vulnerabilities in the ...
Titel
SSA-201384 V1.2 (Last Update: 2022-01-11): Predictable UDP Port Number Vulnerability (NAME:WRECK) in the DNS Module of Nucleus RTOS
Veröffentlicht
11. Januar 2022 01:00
Text
Security researchers discovered and disclosed 9 vulnerabilities in several DNS implementations, also known as “NAME:WRECK” vulnerabilities. The vulnerability described in this advisory is from this set. The DNS client of of the networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) contains a vulnerability related to the handling of ...
Titel
SSA-705111 V1.2 (Last Update: 2022-01-11): Multiple Vulnerabilities (NAME:WRECK) in the DNS Module of Nucleus RTOS
Veröffentlicht
11. Januar 2022 01:00
Text
Security researchers discovered and disclosed 9 vulnerabilities in several DNS implementations, also known as “NAME:WRECK” vulnerabilities. The vulnerabilities described in this advisory are from this set. The DNS client of affected products contains multiple vulnerabilities related to the handling of DNS responses and requests. The most severe could allow an ...
Titel
SSA-324998 V1.0: Multiple Vulnerabilities in SICAM A8000
Veröffentlicht
11. Januar 2022 01:00
Text
SICAM A8000 devices are impacted by two vulnerabilities. The first one could allow a privileged user to enable a debug port with default credentials. The second vulnerability could allow unauthenticated access to certain previously created log files. Siemens has released updates for the affected products and recommends to update to ...
Titel
SSA-439673 V1.0: Information Disclosure Vulnerability in SIPROTEC 5 Devices
Veröffentlicht
11. Januar 2022 01:00
Text
An information disclosure vulnerability in SIPROTEC 5 products could allow an unauthenticated attacker to read device information. Only devices with the hardware variants CP050, CP100 and CP300 are affected. The DIGSI engineering tool can be used to identify the hardware version of your devices. Siemens has released updates for the ...
Titel
SSA-772220 V1.5 (Last Update: 2022-01-11): OpenSSL Vulnerabilities in Industrial Products
Veröffentlicht
11. Januar 2022 01:00
Text
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1k, that allows an unauthenticated attacker to cause a Denial-of-Service (DoS) if a maliciously crafted renegotiation message is sent. Siemens has released updates for several affected products and recommends to update to the latest versions. ...
Titel
SSA-580693 V1.2 (Last Update: 2022-01-11): WIBU Systems CodeMeter Runtime Denial-of-Service Vulnerability in Siemens Products
Veröffentlicht
11. Januar 2022 01:00
Text
WIBU Systems published information about a denial-of-service vulnerability and an associated fix release version of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens products for license management. The vulnerability is described in the section “Vulnerability Classification” below and got assigned the CVE ID CVE-2021-41057. Successful ...
Titel
Philips Engage Software
Veröffentlicht
6. Januar 2022 16:15
Text
This advisory contains mitigations for an Improper Access Control vulnerability in Philips Engage customer support software platform.