Bulletins

US CERT
04/01/2025
Executive summary Many networks have a gap in their defenses for detecting and blocking a malicious technique known as “fast flux.” This technique poses a significant threat to national security, enabling malicious cyber actors to consistently evade detection. Malicious cyber actors, including cybercriminals and nation-state actors, use fast flux to …
SIEMENS CERT
03/20/2025
The SSO login service in Teamcenter contains an open redirect vulnerability that could allow an attacker to redirect the legitimate user to an attacker-chosen URL to steal valid session data. Siemens has released hot fixes for the affected products and recommends to apply them as described in the related Software …
SIEMENS CERT
03/13/2025
Siemens Simcenter Femap is affected by memory corruption vulnerability that could be triggered when the application reads files in .NEU format. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to leak information or potentially perform remote code execution …
US CERT
03/11/2025
Summary Note: This joint Cybersecurity Advisory is part of an ongoing #StopRansomware effort to publish advisories for network defenders detailing various ransomware variants and ransomware threat actors. These #StopRansomware advisories include recently and historically observed tactics, techniques, and procedures (TTPs) and indicators of compromise (IOCs) to help organizations protect against …
SIEMENS CERT
03/11/2025
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
03/11/2025
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures …
SIEMENS CERT
03/11/2025
Siemens Teamcenter Visualization and Tecnomatrix Plant Simulation contains multiple file parsing vulnerabilities that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead …
SIEMENS CERT
03/11/2025
The IPv6 stack of the networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) contains two vulnerabilities when processing IPv6 headers which could allow an attacker to cause a denial of service condition. Siemens has released new versions for several affected products and recommends to update to the latest …