November 2023
Title
SSA-084182 V1.0: Privilege Escalation Vulnerability in Mendix Runtime
Published
Nov. 14, 2023, 1 a.m.
Summary
Mendix Runtime contains a capture-replay flaw which could have an impact to apps built with the platform, if certain preconditions are met that depend on the app’s model and access control design. This could allow authenticated attackers to access or modify objects without proper authorization, or escalate privileges in the ...
Title
SSA-981975 V1.1 (Last Update: 2023-11-14): Information Disclosure Vulnerability in Intel-CPUs (CVE-2022-40982) Impacting SIMATIC IPCs
Published
Nov. 14, 2023, 1 a.m.
Summary
Several Intel-CPU based SIMATIC IPCs are affected by an information exposure vulnerability (CVE-2022-40982) in the CPU that could allow an authenticated local user to potentially read other users’ data [1]. The issue is also known as “Gather Data Sampling” (GDS) or Downfall Attacks. For details refer to the chapter “Additional ...
Title
SSA-197270 V1.0: Information Disclosure Vulnerability in Siemens OPC UA Modeling Editor (SiOME)
Published
Nov. 14, 2023, 1 a.m.
Summary
Siemens OPC UA Modeling Editor (SiOME) is affected by an XML external entity (XXE) injection vulnerability that could allow an attacker to interfere with an application’s processing of XML data and read arbitrary files in the system. Siemens has released a new version for Siemens OPC UA Modelling Editor (SiOME) ...
Title
SSA-150063 V1.0: Multiple Vulnerabilities in SINEC PNI before V2.0
Published
Nov. 14, 2023, 1 a.m.
Summary
SINEC PNI before V2.0 is affected by multiple vulnerabilities. Siemens has released an update for SINEC PNI and recommends to update to the latest version.
Title
SSA-699386 V1.0: Multiple Vulnerabilities in SCALANCE XB-200 / XC-200 / XP-200 / XF-200BA / XR-300WG Family before V4.5
Published
Nov. 14, 2023, 1 a.m.
Summary
SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family before V4.5 is affected by multiple vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.
Title
SSA-137900 V1.0: Multiple Vulnerabilities in COMOS
Published
Nov. 14, 2023, 1 a.m.
Summary
COMOS is affected by multiple vulnerabilities that could allow an attacker to execute arbitrary code or cause denial of service condition, data infiltration or perform access control violations. Siemens has released an update for COMOS and recommends to update to the latest version. Siemens recommends specific countermeasures for products where ...
Title
SSA-099606 V1.0: Multiple Vulnerabilities in SIMATIC MV500 before V3.3.5
Published
Nov. 14, 2023, 1 a.m.
Summary
SIMATIC MV500 before V3.3.5 is affected by multiple vulnerabilities. Siemens has released an update for SIMATIC MV500 and recommends to update to the latest version.
Title
SSA-363107 V1.4 (Last Update: 2023-11-14): An Improper Initialization Vulnerability Affects SIMATIC WinCC Kiosk Mode
Published
Nov. 14, 2023, 1 a.m.
Summary
A vulnerability was found in SIMATIC WinCC that could allow authenticated attackers to escape the Kiosk Mode. Siemens has released updates for the affected products and recommends to update to the latest versions.
Title
SSA-794697 V1.4 (Last Update: 2023-11-14): Vulnerabilities in the Linux Kernel of the SIMATIC S7-1500 TM MFP V1.0
Published
Nov. 14, 2023, 1 a.m.
Summary
Multiple vulnerabilities have been identified in the Linux Kernel of the SIMATIC S7-1500 TM MFP V1.0. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
Title
SSA-787941 V1.4 (Last Update: 2023-11-14): Denial of Service Vulnerability in RUGGEDCOM ROS devices
Published
Nov. 14, 2023, 1 a.m.
Summary
RUGGEDCOM ROS-based devices are vulnerable to a denial of service attack (Slowloris). By sending partial HTTP requests nonstop, with none completed, the affected web servers will be waiting for the completion of each request, occupying all available HTTP connections. The web server recovers by itself once the attack ends. Siemens ...
Title
SSA-264814 V1.2 (Last Update: 2023-11-14): Timing Based Side Channel Vulnerability in the OpenSSL RSA Decryption in SIMATIC Products
Published
Nov. 14, 2023, 1 a.m.
Summary
Several SIMATIC products are affected by a timing based side channel vulnerability in the OpenSSL RSA Decryption (CVE-2023-4304), as disclosed on 2023-02-07 at https://www.openssl.org/news/secadv/20230207.txt. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for ...
Title
Hitachi Energy eSOMS
Published
Nov. 9, 2023, 1 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: eSOMS Vulnerabilities: Generation of Error Message Containing Sensitive Information, Exposure of Sensitive System Information to an Unauthorized Control Sphere 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to disclose ...
Title
Johnson Controls Quantum HD Unity
Published
Nov. 9, 2023, 1 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable Remotely/Low attack complexity Vendor: Johnson Controls Inc. Equipment: Quantum HD Unity Vulnerability: Active Debug Code 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthorized user to access debug features that were accidentally exposed. 3. TECHNICAL DETAILS 3.1 ...
Title
GE MiCOM S1 Agile
Published
Nov. 7, 2023, 1 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Low attack complexity Vendor: General Electric Equipment: MiCOM S1 Agile Vulnerability: Uncontrolled Search Path Element 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to upload malicious files and achieve code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS ...
Title
Weintek EasyBuilder Pro
Published
Nov. 2, 2023, 1 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Weintek Equipment: EasyBuilder Pro Vulnerability: Use of Hard-coded Credentials 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to obtain remote control of a victim's computer as a privileged user. 3. TECHNICAL DETAILS ...
Title
Mitsubishi Electric MELSEC iQ-F Series CPU Module
Published
Nov. 2, 2023, 1 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low attack complexity Equipment: MELSEC iQ-F Series Vulnerability: Improper Restriction of Excessive Authentication Attempts 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a remote attacker to prevent legitimate users from logging into the web server function for a ...
Title
Mitsubishi Electric MELSEC Series
Published
Nov. 2, 2023, 1 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Corporation Equipment: MELSEC Series Vulnerability: Insufficient Verification of Data Authenticity 2. RISK EVALUATION Successful exploitation of this vulnerability may allow a remote attacker to reset the memory of the products to factory default state ...
Title
Schneider Electric SpaceLogic C-Bus Toolkit
Published
Nov. 2, 2023, 1 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: SpaceLogic C-Bus Toolkit Vulnerabilities: Improper Privilege Management, Path Traversal 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to perform remote code execution, which could result in tampering of the ...
Title
Franklin Fueling System TS-550
Published
Nov. 2, 2023, 1 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.3 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available Vendor: Franklin Fueling System Equipment: TS-550 Vulnerability: Use of Password Hash with Insufficient Computational Effort 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to access the device and gain unauthenticated ...
October 2023
Title
Zavio IP Camera
Published
Oct. 31, 2023, 1 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Zavio Equipment: IP Camera Vulnerability: Improper Restriction of Operations within the Bounds of a Memory Buffer, OS Command Injection 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow remote code execution. 3. TECHNICAL DETAILS 3.1 ...
Title
Sielco PolyEco FM Transmitter
Published
Oct. 26, 2023, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available Vendor: Sielco Equipment: PolyEco1000 Vulnerabilities: Session Fixation, Improper Restriction of Excessive Authentication Attempts, Improper Access Control 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to escalate privileges, access restricted pages, ...
Title
Centralite Pearl Thermostat
Published
Oct. 26, 2023, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available Vendor: Centralite Equipment: Pearl Thermostat Vulnerability: Allocation of Resources Without Limits or Throttling 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial of service on the affected ...
Title
Rockwell Automation FactoryTalk View Site Edition
Published
Oct. 26, 2023, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk View Site Edition Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could cause the product to become unavailable and require a restart to recover resulting in a denial-of-service ...
Title
Ashlar-Vellum Cobalt, Graphite, Xenon, Argon, Lithium
Published
Oct. 26, 2023, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Ashlar-Vellum Equipment: Cobalt, Graphite, Xenon, Argon, Lithium, and Cobalt Share Vulnerabilities: Out-of-Bounds Write, Heap-based Buffer Overflow, Out-of-Bounds Read 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code. 3. TECHNICAL DETAILS ...
Title
Dingtian DT-R002
Published
Oct. 26, 2023, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely/public exploits are available Vendor: Dingtian Equipment: DT-R002 Vulnerability: Authentication Bypass by Capture-Replay 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to bypass authentication. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Dingtian DT-R002, ...

Last Updates

BOSCH PSIRT
20.03.2024
CODESYS
28.06.2023
SIEMENS CERT
19.04.2024
US CERT
10.05.2024
US CERT (ICS)
09.05.2024

By Source

Archive

2024
2023
2022
2021
2020
2019
2018
2017

Feeds