CISA (ICS)
07/01/2025
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION : Exploitable remotely/low attack complexity Vendor : FESTO, FESTO Didactic Equipment : CIROS Studio / Education, Automation Suite, FluidDraw, FluidSIM, MES-PC Vulnerability : Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to gain full control of the …
SIEMENS CERT
06/17/2025
Questa and ModelSim (incl. OEM Editions) are affected by multiple vulnerabilities that could allow a local attacker to inject arbitrary code and escalate privileges. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
06/16/2025
SSA-345750 V1.1 (Last Update: 2025-06-16): Default Credentials in Energy Services Using Elspec G5DFR
Energy Services from Siemens (previously known as Managed Applications and Services), sell solutions using Elspec G5 Digital Fault Recorder which contains default credentials with admin privileges. A client configuration with remote access could allow an attacker to gain remote control of the G5DFR component and tamper outputs from the device.
US CERT
06/12/2025
Summary The Cybersecurity and Infrastructure Security Agency (CISA) is releasing this advisory in response to ransomware actors leveraging unpatched instances of a vulnerability in SimpleHelp Remote Monitoring and Management (RMM) to compromise customers of a utility billing software provider. This incident reflects a broader pattern of ransomware actors targeting organizations …
SIEMENS CERT
06/12/2025
SSA-627195 V1.0: Zip Path Traversal Vulnerability in Mendix Studio Pro's Module Installation Process
Mendix Studio Pro contains a vulnerability in the module installation process, that could allow an attacker to write or modify arbitrary files in directories outside a developer’s project directory. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further …
SIEMENS CERT
06/12/2025
The Mendix OIDC SSO module grants read and write access to all tokens exclusively to the Administrator role and could result in privilege misuse by an adversary modifying the module during Mendix development. Siemens has released new versions for several affected products and recommends to update to the latest versions. …
SIEMENS CERT
06/10/2025
SIMOTICS CONNECT 400, Desigo (Power PC-based), APOGEE MEC/MBC/PXC and TALON TC products are affected by a DHCP Client vulnerability as initially reported in SSA-434032 for the Mentor Nucleus Networking Module. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures …