SIEMENS CERT
12/10/2019
The boot loader within RUGGEDCOM ROS contains two vulnerabilities in the loading process of the operating system kernel. The most severe of these vulnerabilities could allow an attacker with local access to the device to execute arbitrary code on an affected device. Siemens recommends specific countermeasures to mitigate this issue.
SIEMENS CERT
12/10/2019
SPPA-T3000 Application Server and MS3000 Migration Server are affected by multiple vulnerabilities. Some of the vulnerabilities can allow an attacker to execute arbitrary code on the server. Exploitation of the vulnerabilities described in this advisory requires access to either Application- or Automation Highway. Both highways should not be exposed if …
SIEMENS CERT
12/10/2019
A vulnerability has been identified in several SIMATIC products. The vulnerability could allow an attacker in a Man-in-the-Middle position to modify network traffic exchanged on port 102/tcp to PLCs of the SIMATIC S7-1200, SIMATIC S7-1500 and SIMATIC SoftwareController CPU families. Siemens has released updates for several affected products, and recommends …
SIEMENS CERT
12/10/2019
Multiple vulnerabilities have been identified in XHQ Operations Intelligence product line. These vulnerabilities could allow for data injection in XHQ's web interfaces. Siemens recommends to update XHQ Operations Intelligence product line to the newest version.
SIEMENS CERT
12/10/2019
The EN100 Ethernet communication modules are affected by security vulnerabilities which could allow an attacker to disclose information. Siemens has released updates for several affected products, is working on updates for the remaining affected products, and recommends specific countermeasures until fixes are available.
SIEMENS CERT
12/10/2019
SiNVR V3 contains seven vulnerabilities in the components Video Server and Central Control Server (CCS), involving authentication bypass (CVE-2019-18337, CVE-2019-18339, CVE-2019-18341), information disclosure (CVE-2019-13947, CVE-2019-18340), path traversal (CVE-2019-18338), and privilege escalation (CVE-2019-18342). Siemens recommends specific countermeasures until fixes are available.
SIEMENS CERT
12/10/2019
The latest firmware updates for the SCALANCE W700 and W1700 wireless device families fix a vulnerability affecting WPA/WPA2 key handling. It might be possible to, by manipulating the EAPOL-Key frames, decrypt the Key Data field without the frame being authenticated. This has impact on WPA/WPA2 architectures using TKIP encryption. The …
SIEMENS CERT
12/10/2019
A vulnerability in the affected products could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends …