SIEMENS CERT
02/22/2018
Several industrial products are affected by a vulnerability that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct Layer 2 access to the affected products. Siemens has released updates for several affected products, is working …
SIEMENS CERT
02/22/2018
Select Ultrasound products from Siemens Healthineers are affected by the Microsoft Windows SMBv1 vulnerabilities. The exploitability of the vulnerabilities depends on the actual configuration and deployment environment of each product. Siemens Healthineers provides updates for the affected products, and recommends specific countermeasures until patches can be applied.
SIEMENS CERT
02/22/2018
Multiple SIMATIC WinCC Add-Ons released in 2015 and earlier include a vulnerable version of Gemalto Sentinel LDK RTE. Gemalto Sentinel LDK RTE is affected by a vulnerability that could allow remote code execution. Siemens recommends to update the affected software component Gemalto Sentinel LDK RTE.
SIEMENS CERT
02/22/2018
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates …
SIEMENS CERT
02/22/2018
Security researchers published information on vulnerabilities known as Spectre and Meltdown. These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Industrial Products include affected processors and are affected by the vulnerabilities.
SIEMENS CERT
02/22/2018
The RUGGEDCOM RCDP protocol is not properly configured after commissioning of RUGGEDCOM ROS based devices and some SCALANCE X switch models and could allow unauthenticated remote users to perform administrative operations. An attacker must be in the same adjacent network and the RCDP daemon must be enabled in order to …
SIEMENS CERT
02/05/2018
The latest update for Desigo PXC devices fixes a vulnerability that could allow unauthenticated remote attackers to upload malicious firmware without prior authentication. Siemens recommends updating to the new version.
SIEMENS CERT
01/25/2018
The latest update for TeleControl Server Basic resolves three vulnerabilities. One of these vulnerabilities could allow an authenticated attacker with network access to escalate his privileges and perform administrative actions. Siemens recommends updating to the new version.