Bulletins

SIEMENS CERT
09/09/2025
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
09/09/2025
Siemens SINAMICS G220, SINAMICS S210, and SINAMICS S200 contains a privilege escalation vulnerability that could allow users to escalate their privileges. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where …
SIEMENS CERT
09/09/2025
Several tools for the SIMOTION system are affected by a local privilege escalation vulnerability. This could allow an attacker to execute arbitrary code with SYSTEM privileges when a legitimate user installs an application that uses the affected setup component. This vulnerability poses a risk only during setup and installation phase …
SIEMENS CERT
09/09/2025
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or …
SIEMENS CERT
09/09/2025
SINEC OS is affected by multiple vulnerabilities due to open UDP ports, which could allow an attacker to access non-sensitive information without authentication or potentially cause temporary denial of service. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
CISA (ICS)
09/04/2025
1. EXECUTIVE SUMMARY CVSS v4 8.8 ATTENTION : Exploitable remotely/low attack complexity Vendor : Honeywell Equipment : OneWireless Wireless Device Manager (WDM) Vulnerabilities : Improper Restriction of Operations within the Bounds of a Memory Buffer, Sensitive Information in Resource Not Removed Before Reuse, Integer Underflow (Wrap or Wraparound), Deployment of …
CISA (ICS)
09/02/2025
1. EXECUTIVE SUMMARY CVSS v4 9.4 ATTENTION : Exploitable from an adjacent network/low attack complexity Vendor : SunPower Equipment : PVS6 Vulnerability : Use of Hard-Coded Credentials 2. RISK EVALUATION Successful exploitation of this vulnerability could allow attackers to gain full access to the device, enabling them to replace firmware, …
CISA (ICS)
09/02/2025
1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION : Low attack complexity Vendor : Fuji Electric Equipment : FRENIC-Loader 4 Vulnerability : Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Fuji …