SIEMENS CERT
12/10/2024
The know-how protection feature in Totally Integrated Automation Portal (TIA Portal) does not properly update the encryption of existing program blocks when a project file is updated. This could allow attackers with access to the project file to recover previous - yet unprotected - versions of the project without the …
SIEMENS CERT
12/10/2024
Mendix Runtime contains an observable response discrepancy vulnerability when validating usernames during authentication. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames. Siemens has released new versions for the affected products and recommends to update to the latest versions. Note that some, Mendix Runtime version lines …
SIEMENS CERT
12/10/2024
The SICAM A8000 CP-8031 and CP-8050 devices are affected by a vulnerability that could allow an attacker with physical access to the device to decrypt the firmware. Siemens has released new firmware and hardware versions for the affected products and recommends to update to the latest versions. Both the firmware …
SIEMENS CERT
12/10/2024
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Customers are advised to consult and implement the workarounds …
SIEMENS CERT
12/10/2024
Several SIMATIC products are affected by a timing based side channel vulnerability in the OpenSSL RSA Decryption (CVE-2023-4304), as disclosed on 2023-02-07 at https://www.openssl.org/news/secadv/20230207.txt. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are …
SIEMENS CERT
12/10/2024
Several SIMATIC products are affected by a type confusion vulnerability relating to OpenSSL X.400 address processing (CVE-2023-0286), as disclosed disclosed on 2023-02-07 at https://www.openssl.org/news/secadv/20230207.txt. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are …
SIEMENS CERT
12/10/2024
A vulnerability in affected devices could allow an attacker to perform a denial ofservice attack if a large amount of Profinet Discovery and Configuration Protocol (DCP) reset packets is sent to the affected devices. Siemens has released new versions for several affected products and recommends to update to the latest …
SIEMENS CERT
12/10/2024
A vulnerability in SENTRON Powercenter 1000/1100 with 3RV2921-5M accessory could allow an attacker to cause a denial of service condition. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.