Juli 2022
Titel
Honeywell Saia Burgess PG5 PCD
Veröffentlicht
26. Juli 2022 16:15
Text
This advisory contains mitigations for Authentication Bypass and Use of a Broken or Risky Cryptographic Algorithm vulnerabilities in Honeywell Saia Burgess PG5 PCD, a PLC.
Titel
Honeywell Safety Manager
Veröffentlicht
26. Juli 2022 16:10
Text
This advisory contains mitigations for Insufficient Verification of Data Authenticity, Missing Authentication for Critical Function, and Use of Hard-coded Credentials vulnerabilities in Honeywell Safety Manager, a safety solution of the Experion Process Knowledge System.
Titel
Mitsubishi Electric MELSEC and MELIPC Series (Update D)
Veröffentlicht
26. Juli 2022 16:00
Text
This updated advisory is a follow up to the advisory update titled ICSA-21-334-02 Mitsubishi Electric MELSEC and MELIPC Series (Update C) that was published June 7, 2022, to the ICS webpage on cisa.gov/ics. This advisory contains mitigations for Uncontrolled Resource Consumption, Improper Handling of Length Parameter Inconsistency, and Improper Input ...
Titel
AutomationDirect Stride Field I/O
Veröffentlicht
22. Juli 2022 04:25
Text
This advisory contains mitigations for an Cleartext Transmission of Sensitive Information vulnerability in AutomationDirect products.
Titel
ICONICS Suite and Mitsubishi Electric MC Works64 Products
Veröffentlicht
21. Juli 2022 19:07
Text
This advisory contains mitigations for an Path Traversal, Deserialization of Untrusted Data, Inclusion of Functionality from Untrusted Control Sphere, Out-of-Bounds Read vulnerabilities in the SCADA products.
Titel
Rockwell Automation ISaGRAF Update A
Veröffentlicht
21. Juli 2022 16:20
Text
This updated advisory is a follow-up to the original advisory titled Rockwell Automation ISaGRAF that was published March 29, 2022, on the ICS webpage on cisa.gov/ics. This advisory contains mitigations for an Improper Restriction of XML External Entity Reference vulnerability in Rockwell Automation ISaGRAF software products.
Titel
Rockwell Automation ISaGRAF Workbench
Veröffentlicht
21. Juli 2022 16:15
Text
This advisory contains mitigations for a Missing Authentication for Critical Function vulnerability in the ISaGRAF Workbench.
Titel
Johnson Controls Metasys ADS, ADX, OAS
Veröffentlicht
21. Juli 2022 16:10
Text
This advisory contains mitigations for an Missing Authentication for Critical Function vulnerability in the Metasys ADS, ADX, OAS.
Titel
ABB Drive Composer, Automation Builder, Mint Workbench
Veröffentlicht
21. Juli 2022 16:05
Text
This advisory contains mitigations for an Improper Privilege Management vulnerabilities in the ABB products.
Titel
MiCODUS MV720 GPS tracker
Veröffentlicht
19. Juli 2022 16:05
Text
This advisory contains mitigations for Use of Hard-coded Credentials, Improper Authentication, Cross-site Scripting, and Authorization Bypass Through User-controlled Key vulnerabilities in the MiCODUS MV720 GPS tracker.
Titel
Dahua ASI7213X-T1 (Update A)
Veröffentlicht
19. Juli 2022 16:00
Text
This updated advisory is a follow-up to the original advisory titled ICSA-22-193-01 Dahua ASI7213X-T1 that was published July 12, 2022, on the ICS webpage on cisa.gov/ics. This advisory contains mitigations for Unrestricted Upload of File with Dangerous Type, Authentication Bypass by Capture-replay, and Generation of Error Message Containing Sensitive Information ...
Titel
Siemens SCALANCE X Switch Devices
Veröffentlicht
14. Juli 2022 16:58
Text
This advisory contains mitigations for Use of Insufficiently Random Values, and Classic Buffer Overflow vulnerabilities in the Siemens SCALANCE X Switch Devices industrial ethernet switches.
Titel
Siemens SIMATIC MV500 Devices
Veröffentlicht
14. Juli 2022 16:54
Text
This advisory contains mitigations for Insufficient Session Expiration, and Missing Authentication for Critical Function vulnerabilities in the Siemens SIMATIC MV500 Devices Optical Readers.
Titel
Siemens Mendix Excel Importer
Veröffentlicht
14. Juli 2022 16:48
Text
This advisory contains mitigations for an XML Entity Expansion vulnerability in the Mendix Excel Importer Module.
Titel
Siemens Datalogics File Parsing Vulnerability
Veröffentlicht
14. Juli 2022 16:46
Text
This advisory contains mitigations for a Heap-based buffer Overflow vulnerability in the Siemens Teamcenter Visualization.
Titel
Siemens PADS Standard/Plus Viewer
Veröffentlicht
14. Juli 2022 16:44
Text
This advisory contains mitigations for an Out-of-bounds Read, Out-of-bounds Write, Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in the PADS Standard and Standard Plus, a PCB schematic design and layout environment.
Titel
Simcenter Femap and Parasolid
Veröffentlicht
14. Juli 2022 16:42
Text
This advisory contains mitigations for an Out-of-bounds Read vulnerability Simcenter Femap, an advanced simulation application, and Parasolid, a 3D geometric modeling tool.
Titel
Siemens Mendix Applications
Veröffentlicht
14. Juli 2022 16:40
Text
This advisory contains mitigations for an Out-of-bounds Read vulnerability in Siemens Mendix Applications, a high productivity app platform.
Titel
Dahua ASI7213X-T1
Veröffentlicht
12. Juli 2022 16:05
Text
This advisory contains mitigations for Improper Input Validation, Unrestricted Upload of File with Dangerous Type, Authentication Bypass by Capture-replay, Generation of Error Message Containing Sensitive Information vulnerabilities in the Dahua ASI7213X-T1 facial recognition access controller.
Titel
Schneider Electric Easergy P5 and P3 (Update A)
Veröffentlicht
12. Juli 2022 16:00
Text
This updated advisory is a follow-up to the original advisory titled ICSA-22-055-03 Schneider Electric Easergy P5 and P3 that was published February 24, 2022, on the ICS webpage on cisa.gov/ics. This advisory contains mitigations for Use of Hard-coded Credentials, Classic Buffer Overflow, and Improper Input Validation vulnerabilities in Schneider Electric ...
Titel
SSA-910883 V1.0: DHCP Client Vulnerability in SINAMICS PERFECT HARMONY GH180 Drives
Veröffentlicht
12. Juli 2022 02:00
Text
Several models of SINAMICS PERFECT HARMONY GH180 Drives are affected by a DHCP client vulnerability (CVE-2021-29998) in the integrated SCALANCE X206-1 device. The vulnerability could allow an attacker to cause a heap-based buffer overflow on that device and use it to get access to the drive’s internal network. The list ...
Titel
SSA-944952 V1.0: Authentication Bypass Vulnerability in Opcenter Quality
Veröffentlicht
12. Juli 2022 02:00
Text
Siemens has released updates for Opcenter Quality to fix an authentication bypass vulnerability. This could allow unauthenticated access to the application or cause denial of service condition for existing users. The issue is based on rich client modules using IbsGailWrapper-interface. After issuing the record the authentication bypass vulnerability could take ...
Titel
SSA-840188 V1.5 (Last Update: 2022-07-12): Multiple Vulnerabilities in SIMATIC WinCC Affecting Other SIMATIC Software Products
Veröffentlicht
12. Juli 2022 02:00
Text
Multiple vulnerabilities were found in SIMATIC WinCC that ultimately could allow local or remote attackers to escalate privileges and read, write or delete critical files. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures ...
Titel
SSA-865333 V1.0: Memory Corruption Vulnerability in EN100 Ethernet Module
Veröffentlicht
12. Juli 2022 02:00
Text
EN100 Ethernet module is affected by memory corruption vulnerability (CVE-2022-30938). Siemens has released an update for the EN100 Ethernet module IEC 61850 variant and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
Titel
SSA-840800 V1.0: Code Injection Vulnerability in RUGGEDCOM ROS
Veröffentlicht
12. Juli 2022 02:00
Text
RUGGEDCOM ROS-based devices are vulnerable to a web-based code injection attack. To execute this attack, it is necessary to access the system via the console. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are ...