Mai 2024
Titel
Rockwell Automation FactoryTalk View SE
Veröffentlicht
16. Mai 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk View SE Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to inject a malicious SQL statement in the SQL database, resulting in expose sensitive ...
Titel
Siemens PS/IGES Parasolid Translator Component
Veröffentlicht
16. Mai 2024 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Titel
Siemens Desigo Fire Safety UL and Cerberus PRO UL Fire Protection Systems
Veröffentlicht
16. Mai 2024 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Titel
Siemens SICAM Products
Veröffentlicht
16. Mai 2024 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Titel
Siemens Simcenter Nastran
Veröffentlicht
16. Mai 2024 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Titel
Remote code execution vulnerability has been found over an insecure connection in the Praesensa Logging Application, Praesideo Logging Application and Praesideo PC Call Station
Veröffentlicht
15. Mai 2024 02:00
Text

BOSCH-SA-106054-BT: A remote code execution vulnerability has been found over an insecure connection in the Praesensa Logging Application, Praesideo Logging Application and Praesideo PC Call Station that allows unauthorized users to execute arbitrary code on the server machine. This exploitation can lead unauthorized access on the target system, compromising the ...

Titel
SUBNET PowerSYSTEM Center and Substation Server
Veröffentlicht
14. Mai 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION: Low attack complexity Vendor: Subnet Solutions Inc. Equipment: PowerSYSTEM Center Vulnerabilities: Reliance on Insufficiently Trustworthy Component 2. RISK EVALUATION Successful exploitation of the vulnerabilities in components used by PowerSYSTEM Center could allow privilege escalation, denial-of-service, or arbitrary code execution. 3. TECHNICAL ...
Titel
Johnson Controls Software House C-CURE 9000
Veröffentlicht
14. Mai 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.7 ATTENTION: Low attack complexity Vendor: Johnson Controls Equipment: Software House C●CURE 9000 Vulnerability: Insertion of Sensitive Information into Log File 2. RISK EVALUATION Successful exploitation of this vulnerability may allow an attacker to access credentials used for access to the application. 3. ...
Titel
Mitsubishi Electric Multiple FA Engineering Software Products
Veröffentlicht
14. Mai 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 6.0 ATTENTION: Low attack complexity Vendor: Mitsubishi Electric Equipment: Multiple FA Engineering Software Products Vulnerabilities: Improper Privilege Management, Uncontrolled Resource Consumption, Out-of-bounds Write, Improper Privilege Management 2. RISK EVALUATION Successful exploitation of these vulnerabilities may allow a local attacker to cause a Windows ...
Titel
Rockwell Automation FactoryTalk Remote Access
Veröffentlicht
14. Mai 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.0 ATTENTION: Low attack complexity Vendor: Rockwell Automation Equipment: Factory Talk Remote Access Vulnerability: Unquoted Search Path or Element 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to enter a malicious executable and run it as a system user, ...
Titel
SSA-258494 V1.0: Stack Overflow Vulnerability in Simcenter Nastran before 2406.90
Veröffentlicht
14. Mai 2024 02:00
Text
Simcenter Nastran is affected by a stack overflow vulnerability that could be triggered when an application binary reads arbitrary string as a file argument. If a user is tricked to run one of the impacted application binary with a malicious string, an attacker could leverage the vulnerability to perform remote ...
Titel
SSA-148641 V1.2 (Last Update: 2024-05-14): XPath Constraint Vulnerability in Mendix Runtime
Veröffentlicht
14. Mai 2024 02:00
Text
A XPath Constraint vulnerability in the Mendix Runtime was discovered, that can affect the running applications. The vulnerability could allow a malicious user to deduce contents of inaccessible attributes and modify sensitive data. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Titel
SSA-240541 V1.3 (Last Update: 2024-05-14): WIBU Systems CodeMeter Heap Buffer Overflow Vulnerability in Industrial Products
Veröffentlicht
14. Mai 2024 02:00
Text
WIBU Systems published information about a heap buffer overflow vulnerability and associated fix releases of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens industrial products for license management. The vulnerability is described in the section ‘Vulnerability Classification’ below and got assigned the CVE ID CVE-2023-3935. ...
Titel
SSA-923361 V1.0: MODEL File Parsing Vulnerability in Tecnomatix Plant Simulation before V2302.0011
Veröffentlicht
14. Mai 2024 02:00
Text
Tecnomatix Plant Simulation contains an out of bounds write vulnerability that could be triggered when the application reads MODEL files. If a user is tricked to open a malicious file using the affected application, this could lead to a crash, and potentially also to arbitrary code execution on the target ...
Titel
SSA-225840 V1.1 (Last Update: 2024-05-14): Vulnerabilities in the Network Communication Stack in Sinteso EN and Cerberus PRO EN Fire Protection Systems
Veröffentlicht
14. Mai 2024 02:00
Text
Several products used in Sinteso EN and Cerberus PRO EN Fire Protection Systems contain buffer overflow vulnerabilities in the network communication stack. Successful exploitation of the vulnerabilities could allow an unauthenticated attacker, who gained access to the fire protection system network, to execute arbitrary code on the affected products (CVE-2024-22039) ...
Titel
SSA-265688 V1.1 (Last Update: 2024-05-14): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1
Veröffentlicht
14. Mai 2024 02:00
Text
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
Titel
SSA-292063 V1.1 (Last Update: 2024-05-14): Multiple Vulnerabilities in Nozomi Guardian/CMC before 22.6.3 and 23.1.0 on RUGGEDCOM APE1808 devices
Veröffentlicht
14. Mai 2024 02:00
Text
Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC before V22.6.3 and 23.1.0. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Customers are advised to consult and ...
Titel
SSA-916916 V1.0: Security Vulnerabilities Fixed in RUGGEDCOM CROSSBOW V5.5
Veröffentlicht
14. Mai 2024 02:00
Text
The RUGGEDCOM CROSSBOW server application before V5.5 contains multiple vulnerabilities that could allow an attacker to execute arbitrary database queries via SQL injection attacks, or upload of arbitrary files to the application’s file system. The majority of the reported vulnerabilities might have a high impact in the availability of the ...
Titel
SSA-093430 V1.0: Multiple Vulnerabilities in SIMATIC RTLS Locating Manager before V3.0
Veröffentlicht
14. Mai 2024 02:00
Text
Siemens has released a new version for SIMATIC RTLS Locating Manager and recommends to update to the latest version.
Titel
SSA-292022 V1.0: Vulnerability in Nozomi Guardian/CMC before 23.4.1 on RUGGEDCOM APE1808 devices
Veröffentlicht
14. Mai 2024 02:00
Text
Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC before 23.4.1. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. Customers are advised to consult and implement the workarounds ...
Titel
SSA-925850 V1.0: Improper Access Control in Polarion ALM
Veröffentlicht
14. Mai 2024 02:00
Text
The Apache Lucene based query engine in Polarion ALM lacks proper access controls. This could allow an authenticated user to query items beyond the user’s allowed projects. Siemens has released a new version for Polarion ALM and recommends to update to the latest version.
Titel
SSA-968170 V1.3 (Last Update: 2024-05-14): Remote Code Execution Vulnerability in SIMATIC STEP 7 V5.x and Derived Products
Veröffentlicht
14. Mai 2024 02:00
Text
SIMATIC STEP 7 and PCS 7 contain a database management system that could allow remote users to use embedded functions of the database (local or in a network share) that have impact on the server. An attacker with network access to the server network could leverage these embedded functions to ...
Titel
SSA-273900 V1.0: Multiple Vulnerabilities in SIMATIC CN 4100 before V3.0
Veröffentlicht
14. Mai 2024 02:00
Text
SIMATIC CN 4100 is vulnerable to use of hard coded credentials including root user and contains an unrestricted USB port that could be misused for insecure boot. Siemens has released a new version for SIMATIC CN 4100 and recommends to update to the latest version.
Titel
SSA-382651 V1.1 (Last Update: 2024-05-14): File Parsing Vulnerability in Solid Edge
Veröffentlicht
14. Mai 2024 02:00
Text
Solid Edge is affected by an out of bounds read vulnerability that could be triggered when the application reads files that contains XT parts. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution in ...
Titel
SSA-976324 V1.0: Multiple IGS File Parsing Vulnerabilities in PS/IGES Parasolid Translator Component before V27.1.215
Veröffentlicht
14. Mai 2024 02:00
Text
PS/IGES Parasolid Translator Component contains multiple file parsing vulnerabilities that could be triggered when the application reads files in IGS file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary ...

Letzte Updates

BOSCH PSIRT
19.07.2024
SIEMENS CERT
22.07.2024
US CERT
24.07.2024
US CERT (ICS)
25.07.2024

Nach Quelle

Archiv

2024
2023
2022
2021
2020
2019
2018
2017