May 2024
Title
Siemens Simcenter Nastran
Published
May 16, 2024, 2 p.m.
Summary
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Title
Siemens SICAM Products
Published
May 16, 2024, 2 p.m.
Summary
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Title
Siemens PS/IGES Parasolid Translator Component
Published
May 16, 2024, 2 p.m.
Summary
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Title
Siemens Desigo Fire Safety UL and Cerberus PRO UL Fire Protection Systems
Published
May 16, 2024, 2 p.m.
Summary
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Title
Rockwell Automation FactoryTalk View SE
Published
May 16, 2024, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk View SE Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to inject a malicious SQL statement in the SQL database, resulting in expose sensitive ...
Title
Siemens SIMATIC CN 4100 Before V3.0
Published
May 16, 2024, 2 p.m.
Summary
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Title
Remote code execution vulnerability has been found over an insecure connection in the Praesensa Logging Application, Praesideo Logging Application and Praesideo PC Call Station
Published
May 15, 2024, 2 a.m.
Summary

BOSCH-SA-106054-BT: A remote code execution vulnerability has been found over an insecure connection in the Praesensa Logging Application, Praesideo Logging Application and Praesideo PC Call Station that allows unauthorized users to execute arbitrary code on the server machine. This exploitation can lead unauthorized access on the target system, compromising the ...

Title
Mitsubishi Electric Multiple FA Engineering Software Products
Published
May 14, 2024, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 6.0 ATTENTION: Low attack complexity Vendor: Mitsubishi Electric Equipment: Multiple FA Engineering Software Products Vulnerabilities: Improper Privilege Management, Uncontrolled Resource Consumption, Out-of-bounds Write, Improper Privilege Management 2. RISK EVALUATION Successful exploitation of these vulnerabilities may allow a local attacker to cause a Windows ...
Title
Johnson Controls Software House C-CURE 9000
Published
May 14, 2024, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.7 ATTENTION: Low attack complexity Vendor: Johnson Controls Equipment: Software House C●CURE 9000 Vulnerability: Insertion of Sensitive Information into Log File 2. RISK EVALUATION Successful exploitation of this vulnerability may allow an attacker to access credentials used for access to the application. 3. ...
Title
Rockwell Automation FactoryTalk Remote Access
Published
May 14, 2024, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.0 ATTENTION: Low attack complexity Vendor: Rockwell Automation Equipment: Factory Talk Remote Access Vulnerability: Unquoted Search Path or Element 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to enter a malicious executable and run it as a system user, ...
Title
SUBNET PowerSYSTEM Center and Substation Server
Published
May 14, 2024, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION: Low attack complexity Vendor: Subnet Solutions Inc. Equipment: PowerSYSTEM Center Vulnerabilities: Reliance on Insufficiently Trustworthy Component 2. RISK EVALUATION Successful exploitation of the vulnerabilities in components used by PowerSYSTEM Center could allow privilege escalation, denial-of-service, or arbitrary code execution. 3. TECHNICAL ...
Title
SSA-665034 V1.1 (Last Update: 2024-05-14): Vulnerability in Nozomi Guardian/CMC before 23.3.0 on RUGGEDCOM APE1808 devices
Published
May 14, 2024, 2 a.m.
Summary
Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC before 23.3.0. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. Customers are advised to consult and implement the workarounds ...
Title
SSA-647455 V1.2 (Last Update: 2024-05-14): Multiple Vulnerabilities in Nozomi Guardian/CMC before 22.6.2 on RUGGEDCOM APE1808 devices
Published
May 14, 2024, 2 a.m.
Summary
Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC before V22.6.2. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Customers are advised to consult and implement the ...
Title
SSA-691715 V1.5 (Last Update: 2024-05-14): Vulnerability in OPC Foundation Local Discovery Server Affecting Siemens Products
Published
May 14, 2024, 2 a.m.
Summary
A vulnerability was identified in OPC Foundation Local Discovery Server which also affects Siemens products that could allow an attacker to escalate privileges under certain circumstances. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and ...
Title
SSA-711309 V1.8 (Last Update: 2024-05-14): Denial of Service Vulnerability in the OPC UA Implementations of SIMATIC Products
Published
May 14, 2024, 2 a.m.
Summary
The OPC UA implementations (ANSI C and C++) as used in several SIMATIC products contain a denial of service vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Siemens has released new versions for several affected products and ...
Title
SSA-661579 V1.0: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go
Published
May 14, 2024, 2 a.m.
Summary
Teamcenter Visualization and JT2Go are affected by multiple file parsing vulnerabilities that could be triggered when the application reads malicious CGM or XML files. If a user is tricked to open a malicious file with the affected products, this could lead the application to crash or potentially lead to arbitrary ...
Title
SSA-593272 V2.1 (Last Update: 2024-05-14): SegmentSmack in Interniche IP-Stack based Industrial Devices
Published
May 14, 2024, 2 a.m.
Summary
A vulnerability exists in affected products that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has released new versions for ...
Title
SSA-589937 V1.0: Multiple Memory Corruption Vulnerabilities in Solid Edge
Published
May 14, 2024, 2 a.m.
Summary
Solid Edge is affected by multiple memory corruption vulnerabilities that could be triggered when the application is parsing PAR files. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to execute arbitrary code in the context of the current ...
Title
SSA-999588 V1.3 (Last Update: 2024-05-14): Multiple Vulnerabilities in User Management Component (UMC) before V2.11.2
Published
May 14, 2024, 2 a.m.
Summary
Siemens User Management Component (UMC) before V2.11.2 is affected by multiple vulnerabilities where the most severe could lead to a restart of the UMC server. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends ...
Title
SSA-935500 V1.1 (Last Update: 2024-05-14): Denial of Service Vulnerability in FTP Server of Nucleus RTOS based APOGEE, TALON and Desigo PXC/PXM Products
Published
May 14, 2024, 2 a.m.
Summary
A denial of service vulnerability has been identified in the Nucleus RTOS (real-time operating system) and reported in the Siemens Security Advisory SSA-313313: https://cert-portal.siemens.com/productcert/html/ssa-313313.html. The products listed below use affected versions of the Nucleus software and inherently contain the vulnerability. Siemens has released new versions for several affected products and ...
Title
SSA-923361 V1.0: MODEL File Parsing Vulnerability in Tecnomatix Plant Simulation before V2302.0011
Published
May 14, 2024, 2 a.m.
Summary
Tecnomatix Plant Simulation contains an out of bounds write vulnerability that could be triggered when the application reads MODEL files. If a user is tricked to open a malicious file using the affected application, this could lead to a crash, and potentially also to arbitrary code execution on the target ...
Title
SSA-976324 V1.0: Multiple IGS File Parsing Vulnerabilities in PS/IGES Parasolid Translator Component before V27.1.215
Published
May 14, 2024, 2 a.m.
Summary
PS/IGES Parasolid Translator Component contains multiple file parsing vulnerabilities that could be triggered when the application reads files in IGS file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary ...
Title
SSA-871717 V1.2 (Last Update: 2024-05-14): Multiple Vulnerabilities in Polarion ALM
Published
May 14, 2024, 2 a.m.
Summary
Polarion ALM is affected by incorrect default path permissions in installation path, and improper authentication in the REST API endpoints of DOORS connector. An attacker could exploit the vulnerabilities for unauthenticated access, or privilege escalation. Siemens has released a new version for Polarion ALM and recommends to update to the ...
Title
SSA-712929 V2.7 (Last Update: 2024-05-14): Denial of Service Vulnerability in OpenSSL (CVE-2022-0778) Affecting Industrial Products
Published
May 14, 2024, 2 a.m.
Summary
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released new versions for several affected products and recommends to update to the ...
Title
SSA-916916 V1.0: Security Vulnerabilities Fixed in RUGGEDCOM CROSSBOW V5.5
Published
May 14, 2024, 2 a.m.
Summary
The RUGGEDCOM CROSSBOW server application before V5.5 contains multiple vulnerabilities that could allow an attacker to execute arbitrary database queries via SQL injection attacks, or upload of arbitrary files to the application’s file system. The majority of the reported vulnerabilities might have a high impact in the availability of the ...

Last Updates

BOSCH PSIRT
15.05.2024
SIEMENS CERT
14.05.2024
US CERT
10.05.2024