Thursday, 30.06.2022
Title
AA22-181A: #StopRansomware: MedusaLocker
Published
June 30, 2022, 7 p.m.
Summary
Original release date: June 30, 2022SummaryActions to take today to mitigate cyber threats from ransomware: • Prioritize remediating known exploited vulnerabilities. • Train users to recognize and report phishing attempts. • Enable and enforce multifactor authentication. Note: this joint Cybersecurity Advisory (CSA) is part of an ongoing #StopRansomware effort to ...
Title
Exemys RME1
Published
June 30, 2022, 4:25 p.m.
Summary
This advisory contains mitigations for an Improper Authentication vulnerability in the Exemys RME1 analog acquisition module.
Title
Yokogawa Wide Area Communication Router
Published
June 30, 2022, 4:20 p.m.
Summary
This advisory contains mitigations for a Use of Insufficiently Random Values vulnerability in the Yokogawa Wide Area Communication Router.
Title
Emerson DeltaV Distributed Control System
Published
June 30, 2022, 4:15 p.m.
Summary
This advisory contains mitigations for a Missing Authentication for Critical Function, Use of Hard-coded Credentials, Insufficient Verification of Data Authenticity, and Use of a Broken or Risky Cryptographic Algorithm vulnerabilities in the Emerson DeltaV Distributed Control System software management platform.
Title
Mitsubishi Electric FA Engineering Software (Update A)
Published
June 30, 2022, 4:05 p.m.
Summary
This updated advisory is a follow-up to the original advisory titled ICSA-21-350-05 Mitsubishi Electric FA Engineering Software that was published December 16, 2021, on the ICS webpage on cisa.gov/ics. This advisory contains mitigations for Out-of-bounds Read, and Integer Underflow vulnerabilities in Mitsubishi Electric's FA Engineering Software products.
Title
CODESYS Gateway Server (Update A)
Published
June 30, 2022, 4 p.m.
Summary
This updated advisory is a follow-up to the original advisory titled ICSA-15-258-02 3S CODESYS Gateway Server Buffer overflow Vulnerability that was published September 15, 2015, on the ICS webpage at cisa.gov/ics. This advisory provides mitigation details for a heap-based buffer overflow vulnerability in CODESYS Gateway Server products.
Tuesday, 28.06.2022
Title
ABB e-Design
Published
June 28, 2022, 4:25 p.m.
Summary
This advisory contains mitigations for an Incorrect Default Permissions vulnerability in ABB e-Design engineering software.
Title
Omron SYSMAC CS/CJ/CP Series and NJ/NX Series
Published
June 28, 2022, 4:20 p.m.
Summary
This advisory contains mitigations for Cleartext Transmission of Sensitive Information, Insufficient Verification of Data Authenticity, and Plaintext Storage of a Password vulnerabilities in Omron SYSMAC CS/CJ/CP Series and NJ/NX Series programmable logic controllers.
Title
Motorola Solutions MOSCAD IP and ACE IP Gateways
Published
June 28, 2022, 4:10 p.m.
Summary
This advisory contains mitigations for a missing authentication for critical function vulnerability in the Motorola Solutions MOSCAD IP and ACE IP Gateways products.
Title
Motorola Solutions MDLC
Published
June 28, 2022, 4:05 p.m.
Summary
This advisory contains mitigations for Use of a Broken or Risky Cryptographic Algorithm, and Plaintext Storage of a Password vulnerabilities in the Motorola Solutions MDLC protocol parser.
Title
Motorola Solutions ACE1000
Published
June 28, 2022, 4 p.m.
Summary
This advisory contains mitigations for Use of Hard-coded Cryptographic Key, Use of Hard-coded Credentials, and Insufficient Verification of Data Authenticity vulnerabilities in the Motorola Solutions ACE1000 remote terminal unit.
Thursday, 23.06.2022
Title
AA22-174A: Malicious Cyber Actors Continue to Exploit Log4Shell in VMware Horizon Systems
Published
June 23, 2022, 7 p.m.
Summary
Original release date: June 23, 2022SummaryActions to take today: • Install fixed builds, updating all affected VMware Horizon and UAG systems to the latest versions. If updates or workarounds were not promptly applied following VMware’s release of updates for Log4Shell in December 2021, treat all affected VMware systems as compromised. ...
Title
OFFIS DCMTK
Published
June 23, 2022, 4:25 p.m.
Summary
This advisory contains mitigations for a path traversal, relative path traversal, NULL pointer reference vulnerability in DCMTK, an OFFIS product.
Title
Yokogawa STARDOM
Published
June 23, 2022, 4:20 p.m.
Summary
This advisory contains mitigations for Cleartext Transmission of Sensitive Information, and Use of Hard-coded Credentials vulnerabilities in the Yokogawa STARDOM network control system.
Title
Yokogawa CAMS for HIS
Published
June 23, 2022, 4:15 p.m.
Summary
This advisory contains mitigations for a Violation of Secure Design Principles vulnerability in the Yokogawa Consolidation Alarm Management Software for Human Interface Station (CAMS for HIS).
Title
Secheron SEPCOS Control and Protection Relay
Published
June 23, 2022, 4:10 p.m.
Summary
This advisory contains mitigations for Improper Enforcement of Behavioral Workflow, Lack of Administrator Control over Security, Improper Privilege Management, and Insufficiently Protected Credentials vulnerabilities in the Secheron SEPCOS Control and Protection Relay.
Title
Pyramid Solutions EtherNet/IP Adapter Development Kit
Published
June 23, 2022, 4:05 p.m.
Summary
This advisory contains mitigations for an Out-of-bounds Write vulnerability in the Pyramid Solutions EtherNet/IP Adapter Development Kit.
Title
Elcomplus SmartICS
Published
June 23, 2022, 4 p.m.
Summary
This advisory contains mitigations for Improper Access Control, Relative Path Traversal, and Cross-site Scripting vulnerabilities in the Elcomplus SmartICS web-based HMI.
Title
Sicherheitsupdate: CODESYS Security Advisories 2022-11 bis 2022-13
Published
June 23, 2022, 2:17 p.m.
Summary
Please check source url for more information.
Wednesday, 22.06.2022
Title
Mitsubishi Electric MELSEC Q and L Series
Published
June 22, 2022, 4:25 a.m.
Summary
This advisory contains mitigations for an Improper Resource Locking vulnerability in Mitsubishi Electric MELSEC Q and L Series CPUs.
Title
Multiple Vulnerabilities PRA-ES8P2S Ethernet-Switch
Published
June 22, 2022, 2 a.m.
Summary

BOSCH-SA-247052-BT: Multiple vulnerabilities were found in the PRA-ES8P2S Ethernet-Switch including an Improper Input Validation, an Improper Privilege Management and an Execution with Unnecessary Privileges vulnerability.These vulnerabilities can give root access and/or administrator privilege to the switch from the network.Customers are advised to upgrade to version 1.01.07 that solves vulnerabilities CVE-2022-32534, ...

Tuesday, 21.06.2022
Title
JTEKT TOYOPUC
Published
June 21, 2022, 4:20 p.m.
Summary
This advisory contains mitigations for a Missing Authentication for Critical Function vulnerability in the JTEKT TOYOPUC programmable logic controller.
Title
Phoenix Contact Classic Line Controllers
Published
June 21, 2022, 4:15 p.m.
Summary
This advisory contains mitigations for an Insufficient Verification of Data Authenticity vulnerability in the Phoenix Contact classic line controllers.
Title
Phoenix Contact ProConOS and MULTIPROG
Published
June 21, 2022, 4:10 p.m.
Summary
This advisory contains mitigations for an Insufficient Verification of Data Authenticity vulnerability in the Phoenix Contact ProConOS and MULTIPROG software development kit.
Title
Phoenix Contact Classic Line Industrial Controllers
Published
June 21, 2022, 4:05 p.m.
Summary
This advisory contains mitigations for an Insufficient Verification of Data Authenticity vulnerability in the Phoenix Contact Classic Line Industrial Controllers.

Last Updates

BOSCH PSIRT
20.03.2024
CODESYS
28.06.2023
SIEMENS CERT
09.04.2024
US CERT
17.04.2024
US CERT (ICS)
18.04.2024

By Source

Archive

2024
2023
2022
2021
2020
2019
2018
2017

Feeds