February 2020
Title
SSA-892012 (Last Update: 2020-02-10): Web Vulnerabilities in SIMATIC S7-1200 CPU Family
Published
Feb. 10, 2020, 1 a.m.
Summary
The latest product release of the SIMATIC S7-1200 CPU fixes two vulnerabilities. The more severe of these vulnerabilities could allow an attacker to inject HTTP headers if unsuspecting users are tricked to click on a malicious link. Another vulnerability resolved in this product release is discussed below.
Title
SSA-731239 (Last Update: 2020-02-10): Vulnerabilities in SIMATIC S7-300 and S7-400 CPUs
Published
Feb. 10, 2020, 1 a.m.
Summary
Two vulnerabilities have been identified in SIMATIC S7-300 and S7-400 CPU families. One vulnerability could lead to a Denial-of-Service, the other vulnerability could result in credential disclosure. Siemens recommends specific mitigations. Siemens will update this advisory when new information becomes available.
Title
SSA-253230 (Last Update: 2020-02-10): Vulnerabilities in SIMATIC S7-1500 CPU family
Published
Feb. 10, 2020, 1 a.m.
Summary
Siemens has released a firmware update for the SIMATIC S7-1500 CPU family which fixes two vulnerabilities. The more severe of these vulnerabilities could allow attackers to cause a Denial-of-Service under certain conditions.
Title
SSA-456423 (Last Update: 2020-02-10): Vulnerabilities in SIMATIC S7-1500 CPU family
Published
Feb. 10, 2020, 1 a.m.
Summary
The new firmware update for the SIMATIC S7-1500 CPU firmware fixes several vulnerabilities, which may have been exploitable via network by Web application attacks or Denial-of-Service attacks with specially crafted network packets on different ports. Siemens addresses and fixes all of these issues by the new firmware update.
Title
SSA-804486 (Last Update: 2020-02-10): Multiple Vulnerabilities in SIMATIC Panels and SIMATIC WinCC (TIA Portal)
Published
Feb. 10, 2020, 1 a.m.
Summary
The latest update for SIMATIC Panel Software and SIMATIC WinCC (TIA Portal) fixes two vulnerabilities. The most severe is a vulnerability which could allow an attacker with network access to the integrated device to read and write variables via SNMP. Siemens recommends to update to the newest version.
Title
SSA-542701 (Last Update: 2020-02-10): Vulnerabilities in SIEMENS LOGO!
Published
Feb. 10, 2020, 1 a.m.
Summary
Multiple vulnerabilities have been identified in SIEMENS LOGO!8 BM devices. The most severe vulnerability could lead to an attacker reading and modifying the device configuration if the attacker has access to port 10005/tcp.
Title
SSA-310688 (Last Update: 2020-02-10): Denial-of-Service Vulnerability in SIMATIC S7-1500 CPU
Published
Feb. 10, 2020, 1 a.m.
Summary
The latest firmware update for the SIMATIC S7-1500 CPU family fixes a vulnerability which could allow an attacker to perform a Denial-of-Service attack under certain conditions. The attacker must have network access to the device to exploit this vulnerability.
Title
SSA-850708 (Last Update: 2020-02-10): Authentication Bypass in SCALANCE X-200 Switch Family
Published
Feb. 10, 2020, 1 a.m.
Summary
A potential vulnerability was discovered in the web server’s authentication of SCALANCE X-200 switches that might allow attackers to hijack web sessions over the network without authentication. Siemens addresses the issue with a firmware update.
Title
SSA-724606 (Last Update: 2020-02-10): Denial-of-Service Vulnerabilities in SIMATIC S7-1200 CPU Family
Published
Feb. 10, 2020, 1 a.m.
Summary
Siemens SIMATIC S7-1200 PLCs, version 2 and higher, allow device management over TCP port 102 (ISO-TSAP) and retrieving status information over UDP port 161 (SNMP). It is possible to cause the device to go into defect mode by sending specially crafted packets to these ports. Siemens addresses these issues with ...
Title
SSA-293562 (Last Update: 2020-02-10): Vulnerabilities in Industrial Products
Published
Feb. 10, 2020, 1 a.m.
Summary
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. The precondition for this scenario is a direct layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released updates ...
Title
SSA-597212 (Last Update: 2020-02-10): Web Vulnerability in SIMATIC S7-1200 CPU Family
Published
Feb. 10, 2020, 1 a.m.
Summary
The latest firmware version V4.1 of the SIMATIC S7-1200 CPU fixes one vulnerability. The vulnerability could allow an attacker to redirect users to untrusted sites under certain conditions.
Title
SSA-268644 (Last Update: 2020-02-10): Spectre-NG (Variants 3a and 4) Vulnerabilities in Industrial Products
Published
Feb. 10, 2020, 1 a.m.
Summary
Security researchers published information on vulnerabilities known as Spectre-NG (Variants 3a and 4). These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Industrial Products include affected processors and are affected by the vulnerabilities.
Title
SSA-914382 (Last Update: 2020-02-10): Denial-of-Service Vulnerability in SIMATIC S7-400 CPU Family
Published
Feb. 10, 2020, 1 a.m.
Summary
SIMATIC S7-400 CPUs are affected by a security vulnerability which could lead to a Denial-of-Service condition of the PLC if specially crafted packets are received and processed. The affected SIMATIC S7-400 CPU hardware versions are in the product cancellation phase or already phased-out. Siemens recommends customers either upgrading to a ...
Title
SSA-254686 (Last Update: 2020-02-10): Foreshadow / L1 Terminal Fault Vulnerabilities in Industrial Products
Published
Feb. 10, 2020, 1 a.m.
Summary
Security researchers published information on vulnerabilities known as Foreshadow and L1 Terminal Fault (L1TF). These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerabilities.
Title
SSA-584286 (Last Update: 2020-02-10): Denial-of-Service Vulnerability in SIMATIC S7-1200 CPU and SIMATIC S7-1500 CPU
Published
Feb. 10, 2020, 1 a.m.
Summary
A vulnerability was identified in SIMATIC S7-1200 and S7-1500 CPUs that could allow an attacker to cause a denial-of-service condition preventing HMI or engineering access to the PLC over port 102/tcp. Siemens has released an update for the S7-1500 product and recommends that customers update to the new version. Siemens ...
Title
SSA-994726 (Last Update: 2020-02-10): GHOST Vulnerability in Siemens Industrial Products
Published
Feb. 10, 2020, 1 a.m.
Summary
The latest updates for the affected products fix the “GHOST” [1] vulnerability identified in glibc library (CVE-2015-0235). Incorrect parsing within the glibc library functions “gethostbyname()” and “gethostbyname2()” could cause a Denial-of-Service of the targeted system. [1] https://nvd.nist.gov/vuln/detail/CVE-2015-0235
Title
SSA-635659 (Last Update: 2020-02-10): Heartbleed Vulnerability in Siemens Industrial Products
Published
Feb. 10, 2020, 1 a.m.
Summary
The "Heartbleed" vulnerability in the OpenSSL cryptographic software library (CVE-2014-0160) affects several Siemens industrial products. Siemens has resolved the issue in all affected industrial products and provides updates which fix this vulnerability.
Title
SSA-087240 (Last Update: 2020-02-10): Vulnerabilities in SIEMENS LOGO!
Published
Feb. 10, 2020, 1 a.m.
Summary
Two vulnerabilities have been identified in SIEMENS LOGO!8 BM devices. The most severe vulnerability could allow an attacker to hijack existing web sessions. Siemens provides LOGO!8 BM FS-05 with firmware version V1.81.2, which fixes the first vulnerability, and recommends specific mitigations for the second vulnerability.
Title
SSA-625789 (Last Update: 2020-02-10): Security Vulnerabilities in Siemens SIMATIC S7-1200 CPU
Published
Feb. 10, 2020, 1 a.m.
Summary
Security experts have examined the SIMATIC S7-1200 Programmable Logic Controller (PLC). This research has revealed some weaknesses in the SIMATIC S71200 CPU communication and authentication functions. Once the automation network is compromised it is possible to demonstrate the following weaknesses using a remote exploit: - Trigger CPU functions by record ...
Title
SSA-100232 (Last Update: 2020-02-10): Denial-of-Service vulnerability in SCALANCE X switches
Published
Feb. 10, 2020, 1 a.m.
Summary
A vulnerability in the affected devices could allow an unauthenticated attacker with network access to an affected device to perform a denial-of-service. Siemens is preparing updates and recommends specific countermeasures until patches are available.
Title
SSA-982399 (Last Update: 2020-02-10): Missing Authentication in TIM 1531 IRC Modules
Published
Feb. 10, 2020, 1 a.m.
Summary
The latest update for TIM 1531 IRC fixes a vulnerability. The device was missing proper authentication when connecting on port 102/tcp, although configured. An attacker needs to be able to connect to port 102/tcp of an affected device in order to exploit this vulnerability. The vulnerability could allow an attacker ...
Title
SSA-833048 (Last Update: 2020-02-10): Vulnerability in SIMATIC S7-1200 CPU Family
Published
Feb. 10, 2020, 1 a.m.
Summary
Siemens became aware that the discontinued products SIMATIC S7-1200 CPUs prior to version 4 could allow for the circumvention of user program block protection under certain conditions.
Title
SSA-321046 (Last Update: 2020-02-10): Denial-of-Service Vulnerability in SCALANCE X-300/X408 Switch Family
Published
Feb. 10, 2020, 1 a.m.
Summary
The latest firmware update for the Siemens SCALANCE X-300 switch family and SCALANCE X 408 fixes two vulnerabilities. The vulnerabilities could allow attackers to cause a device reboot under certain conditions. An attacker must have network access to the device to exploit this vulnerability.
Title
SSA-592007 (Last Update: 2020-02-10): Denial-of-Service Vulnerability in Industrial Products
Published
Feb. 10, 2020, 1 a.m.
Summary
Several industrial controllers are affected by a security vulnerability that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct OSI Layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released ...
Title
SSA-742938 (Last Update: 2020-02-10): Open Ports in SINAMICS S/G Firmware
Published
Feb. 10, 2020, 1 a.m.
Summary
A potential vulnerability was discovered in the SINAMICS S/G converter family which might allow attackers to access administrative functions on the device without authentication. Siemens addresses the issue by a firmware update.

Last Updates

BOSCH PSIRT
19.07.2024
SIEMENS CERT
22.07.2024
US CERT
24.07.2024
US CERT (ICS)
25.07.2024

By Source

Archive

2024
2023
2022
2021
2020
2019
2018
2017

Feeds