Thursday, 14.04.2022
Title
Siemens OpenSSL Vulnerabilities in Industrial Products
Published
April 14, 2022, 5:12 p.m.
Summary
This advisory contains mitigations for a NULL Pointer Dereference vulnerability in the Siemens OpenSSL.
Title
Siemens PROFINET Stack Integrated on Interniche Stack
Published
April 14, 2022, 5:10 p.m.
Summary
This advisory contains mitigations for an Uncontrolled Resource Consumption vulnerability in the Siemens PROFINET Stack Integrated on Interniche Stack.
Title
Siemens Mendix
Published
April 14, 2022, 5:08 p.m.
Summary
This advisory contains mitigations for an Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Siemens Mendix, a software platform to build mobile and web applications.
Title
Siemens SCALANCE W1700
Published
April 14, 2022, 5:06 p.m.
Summary
This advisory contains mitigations for Race Condition, and Improper Input Validation vulnerabilities in the Siemens SCALANCE W1700 wireless communication device.
Title
Siemens SCALANCE X-300 Switches
Published
April 14, 2022, 5:04 p.m.
Summary
This advisory contains mitigations for Improper Input Validation, Use of Insufficiently Random Values, Stack-based Buffer Overflow, Cross-site Request Forgery, Improper Access Control, Basic XSS, Classic Buffer Overflow, Out-of-bounds Read vulnerabilities in Siemens SCALANCE X-300 Switches.
Title
Neues CODESYS Security Advisory 2022-08
Published
April 14, 2022, 4:36 p.m.
Summary
Please check source url for more information.
Wednesday, 13.04.2022
Title
AA22-103A: APT Cyber Tools Targeting ICS/SCADA Devices
Published
April 13, 2022, 7 p.m.
Summary
Original release date: April 13, 2022SummaryActions to Take Today to Protect ICS/SCADA Devices: • Enforce multifactor authentication for all remote access to ICS networks and devices whenever possible. • Change all passwords to ICS/SCADA devices and systems on a consistent schedule, especially all default passwords, to device-unique strong passwords to ...
Tuesday, 12.04.2022
Title
Valmet DNA
Published
April 12, 2022, 4:20 p.m.
Summary
This advisory contains mitigations for an Inadequate Encryption Strength vulnerability in Valmet DNA distributed control system products.
Title
Mitsubishi Electric MELSEC-Q Series C Controller Module
Published
April 12, 2022, 4:15 p.m.
Summary
This advisory contains mitigations for a Heap-based Buffer Overflow vulnerability in some MELSEC-Q Series C Controller Modules using Wind River VxWorks Version 6.4.
Title
Mitsubishi Electric GT25-WLAN
Published
April 12, 2022, 4:05 p.m.
Summary
This advisory contains mitigations for Improper Removal of Sensitive Information Before Storage or Transfer, Inadequate Encryption Strength, Missing Authentication for Critical Function, Injection, and Improper Input Validation vulnerabilities in Mitsubishi Electric GT25-WLAN wireless communication units.
Title
Aethon TUG Home Base Server
Published
April 12, 2022, 4 p.m.
Summary
This advisory contains mitigations for Missing Authorization, Channel Accessible by Non-endpoint, and Cross-site Scripting vulnerabilities in the Aethon TUG Home Base Server; a server used to control and communicate with autonomous mobile robots in hospitals.
Title
SSA-676336 V1.1 (Last Update: 2022-04-12): OpenSSH Vulnerabilities in SCALANCE X-200 and X-300/X408 Switches
Published
April 12, 2022, 2 a.m.
Summary
The latest update of the SCALANCE X-200 and X-300/X408 switches families fixes multiple OpenSSH vulnerabilities. The most severe of these vulnerabilities could allow a denial of service condition. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and ...
Title
SSA-764417 V1.2 (Last Update: 2022-04-12): Multiple Vulnerabilities in RUGGEDCOM Devices
Published
April 12, 2022, 2 a.m.
Summary
There is an insecure cryptographic vulnerability for the affected RUGGEDCOM devices. If an attacker were to exploit this, they could gain privileged functions. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
Title
SSA-772220 V1.8 (Last Update: 2022-04-12): OpenSSL Vulnerabilities in Industrial Products
Published
April 12, 2022, 2 a.m.
Summary
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1k, that allows an unauthenticated attacker to cause a Denial-of-Service (DoS) if a maliciously crafted renegotiation message is sent . Siemens has released updates for several affected products and recommends to update to the latest ...
Title
SSA-780073 V2.1 (Last Update: 2022-04-12): Denial of Service Vulnerability in PROFINET Devices via DCE-RPC Packets
Published
April 12, 2022, 2 a.m.
Summary
Products that include the Siemens PROFINET-IO (PNIO) stack in versions prior V06.00 are potentially affected by a denial of service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens ...
Title
SSA-787292 V1.1 (Last Update: 2022-04-12): Denial-of-Service Vulnerability in SIMATIC RFID Readers
Published
April 12, 2022, 2 a.m.
Summary
The latest updates for SIMATIC RF products fix a vulnerability that could allow an unauthorized attacker to crash the OPC UA service of the affected devices. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific ...
Title
SSA-840188 V1.3 (Last Update: 2022-04-12): Multiple Vulnerabilities in SIMATIC WinCC Affecting Other SIMATIC Software Products
Published
April 12, 2022, 2 a.m.
Summary
Multiple vulnerabilities were found in SIMATIC WinCC that ultimately could allow local or remote attackers to escalate privileges and read, write or delete critical files. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures ...
Title
SSA-914168 V1.1 (Last Update: 2022-04-12): Multiple Vulnerabilities in SIMATIC WinCC Affecting Other SIMATIC Software Products
Published
April 12, 2022, 2 a.m.
Summary
Multiple vulnerabilities were found in SIMATIC WinCC that ultimately could allow attackers to retrieve and brute force password hashes and access other systems. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products ...
Title
SSA-995338 V1.2 (Last Update: 2022-04-12): Multiple Vulnerabilities in COMOS Web
Published
April 12, 2022, 2 a.m.
Summary
Multiple vulnerabilities were identified in the web components of COMOS that could allow an attacker to conduct code injections, store data in undesired locations, execute arbitrary SQL statements, and run cross-site request forgery attacks. Siemens has released updates for several affected products and recommends to update to the latest versions. ...
Title
SSA-978220 V1.6 (Last Update: 2022-04-12): Denial of Service Vulnerability over SNMP in Multiple Industrial Products
Published
April 12, 2022, 2 a.m.
Summary
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a denial of service attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing further updates ...
Title
SSA-316850 V1.0: Unauthenticated File Access in SICAM A8000 Devices
Published
April 12, 2022, 2 a.m.
Summary
SICAM A8000 CP-8050 and CP-8031 devices contain vulnerabilities that could allow an attacker to access files without authentication. Siemens has released updates for the affected products and recommends to update to the latest versions.
Title
SSA-350757 V1.0: Improper Access Control Vulnerability in TIA Portal Affecting S7-1200 and S7-1500 CPUs Web Server (Incl. Related ET200 CPUs and SIPLUS variants)
Published
April 12, 2022, 2 a.m.
Summary
An attacker could achieve privilege escalation on the web server of certain devices configured by SIMATIC STEP 7 (TIA Portal) due to incorrect handling of the webserver’s user management configuration during downloading. This only affects the S7-1200 and S7-1500 CPUs’ (incl. related ET200 CPUs and SIPLUS variants) web server, when ...
Title
SSA-392912 V1.0: Multiple Denial Of Service Vulnerabilities in SCALANCE W1700 Devices
Published
April 12, 2022, 2 a.m.
Summary
Vulnerabilities have been identified in devices of the SCALANCE W-1700 (11ac) family that could allow an attacker to cause various denial of service conditions. Siemens has released updates for the affected products and recommends to update to the latest versions.
Title
SSA-414513 V1.0: Information Disclosure Vulnerability in Mendix
Published
April 12, 2022, 2 a.m.
Summary
An information disclosure vulnerability in Mendix applications was discovered. The vulnerability could allow to read sensitive data. Siemens has released an update for the Mendix Applications using Mendix 9 and recommends to update to the latest version. Siemens recommends countermeasures for products where updates are not, or not yet available.
Title
SSA-446448 V1.0: Denial of Service Vulnerability in PROFINET Stack Integrated on Interniche Stack
Published
April 12, 2022, 2 a.m.
Summary
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, contains a vulnerability that could allow an attacker to cause a denial of service condition on affected industrial products. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further ...