• 1
  • 2 (current)
Tuesday, 09.01.2024
Title
SSA-480095 V1.1 (Last Update: 2024-01-09): Vulnerabilities in the Web Interface of SICAM Q100 Devices before V2.60
Published
Jan. 9, 2024, 1 a.m.
Summary
The web server of SICAM Q100 devices, versions before V2.60, contains a Cross Site Request Forgery (CSRF) vulnerability and is missing cookie protection flags. This could allow an attacker to perform arbitrary actions on the device on behalf of a legitimate user, or impersonate that user. Siemens has released new ...
Title
SSA-570294 V1.1 (Last Update: 2024-01-09): Multiple Vulnerabilities in SICAM Q100 Before V2.50
Published
Jan. 9, 2024, 1 a.m.
Summary
SICAM Q100 devices contain multiple vulnerabilities that could allow an attacker to take over the session of a logged in user or to inject custom code. Siemens has released updates for the affected products and recommends to update to the latest versions.
Title
SSA-583634 V1.0: Command Injection Vulnerability in the CPCI85 Firmware of SICAM A8000 Devices
Published
Jan. 9, 2024, 1 a.m.
Summary
The CPCI85 firmware of SICAM A8000 CP-8031 and CP-8050 is affected by a command injection vulnerability that could allow an authenticated remote attacker to inject commands that are executed on the device with root privileges during device startup. Siemens has released new versions for the affected products and recommends to ...
Title
SSA-589891 V1.0: Multiple PAR File Parsing Vulnerabilities in Solid Edge
Published
Jan. 9, 2024, 1 a.m.
Summary
Siemens Solid Edge 2023 has released Update 10, that fixes multiple vulnerabilities that could be triggered when the application reads PAR files. If a user is tricked to open a malicious file using the affected application, this could lead to a crash, and potentially also to arbitrary code execution on ...
Title
SSA-702935 V1.0: Redfish Server Vulnerability in maxView Storage Manager
Published
Jan. 9, 2024, 1 a.m.
Summary
MaxView Storage Manager shipped with affected SIMATIC IPCs contains a Redfish Server Vulnerability that could provide unauthorized access. Microchip has released new versions for the affected products and recommends to update to the latest versions.
Title
SSA-711309 V1.4 (Last Update: 2024-01-09): Denial of Service Vulnerability in the OPC UA Implementations of SIMATIC Products
Published
Jan. 9, 2024, 1 a.m.
Summary
The OPC UA implementations (ANSI C and C++) as used in several SIMATIC products contain a denial of service vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Siemens has released updates for several affected products and recommends ...
Title
SSA-712929 V2.5 (Last Update: 2024-01-09): Denial of Service Vulnerability in OpenSSL (CVE-2022-0778) Affecting Industrial Products
Published
Jan. 9, 2024, 1 a.m.
Summary
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released updates for several affected products and recommends to update to the latest ...
Title
SSA-761617 V1.2 (Last Update: 2024-01-09): Authentication Bypass and Information Disclosure Vulnerabilities in SiNVR/SiVMS Video Server
Published
Jan. 9, 2024, 1 a.m.
Summary
The Video Server application in SiNVR/SiVMS solutions contains two vulnerabilities involving authentication bypass (CVE-2019-18339) and information disclosure (CVE-2019-18340). PKE has released an update of the application that fixes CVE-2019-18339. This update is not available under the former Siemens OEM brand name SiNVR. For details contact PKE (https://pke.at/). Siemens recommends specific ...
Title
SSA-761844 V1.1 (Last Update: 2024-01-09): Multiple Vulnerabilities in Control Center Server (CCS)
Published
Jan. 9, 2024, 1 a.m.
Summary
The advisory informs about multiple vulnerabilities in the Central Control Server (CCS) application, as initially reported in SSA-761617 (https://cert-portal.siemens.com/productcert/html/ssa-761617.html) on 2019-12-10 and SSA-844761 (https://cert-portal.siemens.com/productcert/html/ssa-844761.html) on 2020-03-10. The vulnerabilities involve authentication bypass (CVE-2019-18337, CVE-2019-18341), path traversal (CVE-2019-18338, CVE-2019-19290), information disclosure (CVE-2019-13947, CVE-2019-18340, CVE-2019-19291), privilege escalation (CVE-2019-18342), SQL injection (CVE-2019-19292), cross-site scripting ...
Title
SSA-772220 V2.3 (Last Update: 2024-01-09): OpenSSL Vulnerabilities in Industrial Products
Published
Jan. 9, 2024, 1 a.m.
Summary
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1k, that allows an unauthenticated attacker to cause a Denial-of-Service (DoS) if a maliciously crafted renegotiation message is sent. Siemens has released new versions for several affected products and recommends to update to the latest ...
Title
SSA-777015 V1.0: Multiple Vulnerabilities in SIMATIC CN 4100 before V2.7
Published
Jan. 9, 2024, 1 a.m.
Summary
SIMATIC CN 4100 is vulnerable to authorization bypass through user-controlled key, use of default credentials and unauthenticated IP address change that could allow an attacker to remotely login as root or cause denial of service condition of the device. Siemens has released a new version for SIMATIC CN 4100 and ...
Title
SSA-786191 V1.0: Local Privilege Escalation Vulnerability in Spectrum Power 7
Published
Jan. 9, 2024, 1 a.m.
Summary
Spectrum Power 7 is affected by a vulnerability that could allow an authenticated local attacker to inject arbitrary code and gain root access. Siemens has released an update for Spectrum Power 7 and recommends to update to the latest version.
Title
SSA-794653 V1.0: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go
Published
Jan. 9, 2024, 1 a.m.
Summary
Siemens Teamcenter Visualization and JT2Go are affected by multiple file parsing vulnerabilities that could be triggered when the application reads malicious CGM files. If a user is tricked to open a malicious CGM file with the affected products, this could lead the application to crash or potentially lead to arbitrary ...
Title
SSA-794697 V1.6 (Last Update: 2024-01-09): Vulnerabilities in the Linux Kernel of the SIMATIC S7-1500 TM MFP V1.0
Published
Jan. 9, 2024, 1 a.m.
Summary
Multiple vulnerabilities have been identified in the Linux Kernel of the SIMATIC S7-1500 TM MFP V1.0. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
Monday, 08.01.2024
Title
Multiple vulnerabilities in Nexo cordless nutrunner
Published
Jan. 8, 2024, 1 a.m.
Summary

BOSCH-SA-711465: The Nexo cordless nutrunner running NEXO-OS V1500-SP2 has some vulnerabilities which allows an attacker: - to read/upload/download/delete arbitrary files in all paths of the system, - to inject and execute arbitrary client-side script code, arbitrary HTTP response headers or manipulate HTTP response bodies inside a victim's session, - to ...

Thursday, 04.01.2024
Title
Rockwell Automation FactoryTalk Activation
Published
Jan. 4, 2024, 1 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk Activation Manager Vulnerabilities: Out-of-Bounds Write 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in a buffer overflow and allow the attacker to gain full access to the system. 3. TECHNICAL ...
  • 1
  • 2 (current)

Last Updates

BOSCH PSIRT
20.03.2024
CODESYS
28.06.2023
SIEMENS CERT
19.04.2024
US CERT
17.04.2024
US CERT (ICS)
07.05.2024

By Source

Archive

2024
2023
2022
2021
2020
2019
2018
2017

Feeds