November 2020
Title
SSA-492828 (Last Update: 2020-11-10): Denial-of-Service Vulnerability in SIMATIC S7-300 CPUs and SINUMERIK Controller
Published
Nov. 10, 2020, 1 a.m.
Summary
A vulnerability in S7-300 might allow an attacker to cause a Denial-of-Service condition on port 102 of the affected devices by sending specially crafted packets. Siemens is preparing updates and recommends specific countermeasures until fixes are available.
October 2020
Title
SSA-384879 (Last Update: 2020-10-13): Authentication Bypass Vulnerability in SIPORT MP
Published
Oct. 13, 2020, 2 a.m.
Summary
SIPORT MP version 3.2.1 fixes an authentication bypass vulnerability which could enable an attacker to impersonate other users of the system and perform administrative actions. Siemens recommends to apply the update.
Title
SSA-226339 (Last Update: 2020-10-13): Multiple Web Application Vulnerabilities in Desigo Insight
Published
Oct. 13, 2020, 2 a.m.
Summary
The latest hotfix for Desigo Insight fixes three vulnerabilities that have been identified in the web server, including SQL injection (CVE-2020-15792), clickjacking (CVE-2020-15793), and full path disclosure (CVE-2020-15794). Siemens recommends updating to the latest version of Desigo Insight and to apply the hotfix.
Title
SSA-689071 (Last Update: 2020-10-13): DNSMasq Vulnerabilities in SCALANCE W1750D, SCALANCE M-800 / S615 and RUGGEDCOM RM1224
Published
Oct. 13, 2020, 2 a.m.
Summary
Multiple vulnerabilities have been identified in SCALANCE W1750D, SCALANCE M-800 / S615 and RUGGEDCOM RM1224 devices. The highest scored vulnerability could allow a remote attacker to crash the DNS service or execute arbitrary code. The attacker must be able to craft malicious DNS responses and inject them into the network ...
Title
SSA-534763 (Last Update: 2020-10-13): Special Register Buffer Data Sampling (SRBDS) aka Crosstalk in Industrial Products
Published
Oct. 13, 2020, 2 a.m.
Summary
Security researchers published information on a vulnerability known as Crosstalk (INTEL-SA-00320). This vulnerability affects modern Intel processors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerability. Siemens is preparing updates and recommends specific countermeasures until fixes are available.
Title
SSA-462066 (Last Update: 2020-10-13): Vulnerability known as TCP SACK PANIC in Industrial Products
Published
Oct. 13, 2020, 2 a.m.
Summary
Multiple industrial products are affected by a vulnerability in the kernel known as TCP SACK PANIC. The vulnerability could allow a remote attacker to cause a denial of service condition. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing further ...
Title
SSA-455843 (Last Update: 2020-10-13): WIBU Systems CodeMeter Runtime Vulnerabilities in Siemens and Siemens Energy Products
Published
Oct. 13, 2020, 2 a.m.
Summary
CISA and WIBU Systems disclosed six vulnerabilities in different versions of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens and Siemens Energy products for license management. The vulnerabilities are described in the section “Vulnerability Classification” below and got assigned the CVE IDs CVE-2020-14509, CVE-2020-14513, CVE-2020-14515, ...
Title
SSB-439005 (Last Update: 2020-10-13): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Published
Oct. 13, 2020, 2 a.m.
Summary
Title
SSA-398519 (Last Update: 2020-10-13): Vulnerabilities in Intel CPUs (November 2019)
Published
Oct. 13, 2020, 2 a.m.
Summary
Intel has published information on vulnerabilities in Intel products in November 2019. In this advisory Siemens only explicitly mentions the vulnerabilities from the “Intel® CPU Security Advisory” and one vulnerability from “Intel® CSME, Intel® SPS, Intel® TXE, Intel® AMT, Intel® PTT and Intel® DAL Advisory” and lists the Siemens IPC ...
Title
SSA-381684 (Last Update: 2020-10-13): Improper Password Protection during Authentication in SIMATIC S7-300 and S7-400 CPUs and Derived Products
Published
Oct. 13, 2020, 2 a.m.
Summary
A vulnerability has been identified in SIMATIC S7-300 and S7-400 CPU families and derived products, which could result in credential disclosure. Siemens recommends countermeasures as there are currently no fixes available.
September 2020
Title
SSA-377115 (Last Update: 2020-09-08): SegmentSmack in Linux IP-Stack based Industrial Devices
Published
Sept. 8, 2020, 2 a.m.
Summary
The latest updates for the affected products fix a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has ...
Title
SSB-439005 (Last Update: 2020-09-08): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Published
Sept. 8, 2020, 2 a.m.
Summary
Title
SSA-436520 (Last Update: 2020-09-08): XSS and CSRF Vulnerabilities in Polarion Subversion Webclient
Published
Sept. 8, 2020, 2 a.m.
Summary
Multiple cross-site scripting (XSS) vulnerabilities were found in the subversion webclient of Polarion. In addition, the webclient doesn’t have any cross-site request forgery (CSRF) protection. An attacker could inject client side script to induce the victim to issue an HTTP request that would lead to a state changing operation. Siemens ...
Title
SSA-480230 (Last Update: 2020-09-08): Denial-of-Service in Webserver of Industrial Products
Published
Sept. 8, 2020, 2 a.m.
Summary
A vulnerability in the affected devices could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing further updates and recommends specific ...
Title
SSA-473245 (Last Update: 2020-09-08): Denial-of-Service Vulnerability in Profinet Devices
Published
Sept. 8, 2020, 2 a.m.
Summary
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of specially crafted UDP packets are sent to the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates ...
Title
SSA-462066 (Last Update: 2020-09-08): Vulnerability known as TCP SACK PANIC in Industrial Products
Published
Sept. 8, 2020, 2 a.m.
Summary
Multiple industrial products are affected by a vulnerability in the kernel known as TCP SACK PANIC. The vulnerability could allow a remote attacker to cause a denial of service condition. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing further ...
Title
SSA-251935 (Last Update: 2020-09-08): Multiple Privilege Escalation Vulnerabilities in SIMATIC RTLS Locating Manager
Published
Sept. 8, 2020, 2 a.m.
Summary
The latest update for SIMATIC RTLS Locating Manager fixes various vulnerabilities that could allow a low-privileged local user to escalate privileges. Siemens recommends to apply the update of the SIMATIC RTLS Locating Manager.
Title
SSA-841348 (Last Update: 2020-09-08): Multiple Vulnerabilities in the UMC Stack
Published
Sept. 8, 2020, 2 a.m.
Summary
The latest update for the below listed products fixes two security vulnerabilities that could allow an attacker to cause a partial Denial-of-Service on the UMC component of the affected devices under certain circumstances, and one vulnerability that could allow an attacker to locally escalate privileges from a user with administrative ...
Title
SSA-381684 (Last Update: 2020-09-08): Improper Password Protection during Authentication in SIMATIC S7-300 and S7-400 CPUs
Published
Sept. 8, 2020, 2 a.m.
Summary
A vulnerability has been identified in SIMATIC S7-300 and S7-400 CPU families, which could result in credential disclosure. Siemens recommends countermeasures as there are currently no fixes available.
Title
SSA-534763 (Last Update: 2020-09-08): Special Register Buffer Data Sampling (SRBDS) aka Crosstalk in Industrial Products
Published
Sept. 8, 2020, 2 a.m.
Summary
Security researchers published information on a vulnerability known as Crosstalk (INTEL-SA-00320). This vulnerability affects modern Intel processors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerability. Siemens is preparing updates and recommends specific countermeasures until fixes are available.
Title
SSA-542525 (Last Update: 2020-09-08): Authentication Vulnerabilities in SIMATIC HMI Products
Published
Sept. 8, 2020, 2 a.m.
Summary
SIMATIC HMI Products are affected by two vulnerabilities that could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
Title
SSA-568969 (Last Update: 2020-09-08): Insecure Storage of Sensitive Information in Spectrum Power™ 4
Published
Sept. 8, 2020, 2 a.m.
Summary
Vulnerabilities in Spectrum Power™ 4 could allow an unauthorized attacker to retrieve a list of software users, or in certain cases to list the contents of a directory. Siemens has released updates and configuration recommendations for Spectrum Power™ 4 in order to mitigate the issues.
Title
SSA-455843 (Last Update: 2020-09-08): WIBU Systems CodeMeter Runtime Vulnerabilities in Siemens and Siemens Energy Products
Published
Sept. 8, 2020, 2 a.m.
Summary
CISA and WIBU Systems disclosed six vulnerabilities in different versions of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens and Siemens Energy products for license management. The vulnerabilities are described in the section “Vulnerability Classification” below and got assigned the CVE IDs CVE-2020-14509, CVE-2020-14513, CVE-2020-14515, ...
Title
SSA-709003 (Last Update: 2020-09-08): Privilege Escalation Vulnerability in License Management Utility (LMU)
Published
Sept. 8, 2020, 2 a.m.
Summary
The latest update for the License Management Utility (LMU), which is used by multiple Siemens building technology products, fixes a vulnerability that could allow local users to escalate privileges and execute code as local SYSTEM user. Siemens has released an update version of LMU, recommends to install this update on ...
Title
SSA-780073 (Last Update: 2020-09-08): Denial-of-Service Vulnerability in PROFINET Devices via DCE-RPC Packets
Published
Sept. 8, 2020, 2 a.m.
Summary
Products that include the Siemens PROFINET-IO (PNIO) stack in versions prior V06.00 are potentially affected by a denial-of-service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing ...

Last Updates

BOSCH PSIRT
19.07.2024
SIEMENS CERT
22.07.2024
US CERT
24.07.2024
US CERT (ICS)
25.07.2024

By Source

Archive

2024
2023
2022
2021
2020
2019
2018
2017