Titel
SSA-158827 V1.0: Denial-of-Service Vulnerability in Automation License Manager
Veröffentlicht
10. August 2021 02:00
Text
A vulnerability was identified in the Automation License Manager software that could be triggered by sending specially crafted packets to port 4410/tcp of an affected system. This could cause a denial-of-service preventing legitimate users from using the system. Siemens has released an update for the Automation License Manager 6 and ...
Titel
Cross Site Request Forgery (CSRF) vulnerability in Bosch IP cameras
Veröffentlicht
4. August 2021 02:00
Text

BOSCH-SA-033305-BT: The possibility to conduct a CSRF (Cross Site Request Forgery) attack was discovered in a Penetration Test from Kaspersky ICS CERT during a certification effort from Bosch. Bosch rates this vulnerability with CVSSv3.1 base scores of 7.5 (High), where the actual rating depends on the final rating specific to ...

Titel
SSA-789208 V1.0: Multiple Vulnerabilities (INFRA:HALT) in Interniche IP-Stack based Low Voltage Devices
Veröffentlicht
4. August 2021 02:00
Text
Security researchers discovered and disclosed 14 vulnerabilities in the Interniche IP stack, also known as “INFRA:HALT” vulnerabilities [0]. This advisory describes the impact to Siemens low voltage products, which are only affected by four out of the 14 vulnerabilities. Siemens has released updates for the affected products and recommends to ...
Juli 2021
Titel
AA21-209A: Top Routinely Exploited Vulnerabilities
Veröffentlicht
28. Juli 2021 14:00
Text
Original release date: July 28, 2021 | Last revised: August 20, 2021SummaryThis Joint Cybersecurity Advisory was coauthored by the U.S. Cybersecurity and Infrastructure Security Agency (CISA), the Australian Cyber Security Centre (ACSC), the United Kingdom’s National Cyber Security Centre (NCSC), and the U.S. Federal Bureau of Investigation (FBI). This advisory ...
Titel
AA21-201A: Chinese Gas Pipeline Intrusion Campaign, 2011 to 2013
Veröffentlicht
20. Juli 2021 15:00
Text
Original release date: July 20, 2021 | Last revised: July 21, 2021SummaryThis Advisory uses the MITRE Adversarial Tactics, Techniques, and Common Knowledge (ATT&CK®) framework, Version 9. See the ATT&CK for Enterprise for all referenced threat actor tactics and techniques. Note: CISA released technical information, including indicators of compromise (IOCs), provided ...
Titel
Vulnerabilities in CODESYS V2 runtime systems
Veröffentlicht
20. Juli 2021 02:00
Text

BOSCH-SA-670099: The compact systems CS351E and CS351S and the communication module KE350G with integrated PLC contain technology from CODESYS GmbH. The manufacturer CODESYS GmbH published security bulletins \[1\]\[2\] about a weakness in the protocol for the communication between the PLC runtime and clients. By exploiting these vulnerabilities, attackers can send ...

Titel
AA21-200A: Tactics, Techniques, and Procedures of Indicted APT40 Actors Associated with China’s MSS Hainan State Security Department
Veröffentlicht
19. Juli 2021 13:00
Text
Original release date: July 19, 2021 | Last revised: July 20, 2021SummaryThis Joint Cybersecurity Advisory was written by the Federal Bureau of Investigation (FBI) and the Cybersecurity and Infrastructure Security Agency (CISA) to provide information on a Chinese Advanced Persistent Threat (APT) group known in open-source reporting as APT40. This ...
Titel
AA21-200B: Chinese State-Sponsored Cyber Operations: Observed TTPs
Veröffentlicht
19. Juli 2021 13:00
Text
Original release date: July 19, 2021 | Last revised: August 20, 2021SummaryThis advisory uses the MITRE Adversarial Tactics, Techniques, and Common Knowledge (ATT&CK®) framework, Version 9, and MITRE D3FEND™ framework, version 0.9.2-BETA-3. See the ATT&CK for Enterprise for all referenced threat actor tactics and techniques and the D3FEND framework for ...
Titel
SSA-434535 V1.0: Memory Protection Bypass Vulnerability in SINAMICS PERFECT HARMONY GH180 Drives
Veröffentlicht
13. Juli 2021 02:00
Text
Several models of SINAMICS PERFECT HARMONY GH180 Drives are affected by a memory protection bypass vulnerability in the integrated S7-1500 or S7-1200 CPU that could allow an attacker to write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks on the CPU. Siemens ...
Titel
SSA-483182 V1.0: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.2
Veröffentlicht
13. Juli 2021 02:00
Text
Siemens has released version V13.2 for JT2Go and Teamcenter Visualization to fix multiple vulnerabilities that could be triggered when the products read files in different file formats (GIF, TIFF, BMP, J2K, JT, SGI, PDF, PCT, PCX, PAR and ASM ). If a user is tricked to opening of a malicious ...
Titel
SSA-462066 V2.4 (Last Update: 2021-07-13): Vulnerability known as TCP SACK PANIC in Industrial Products
Veröffentlicht
13. Juli 2021 02:00
Text
Multiple industrial products are affected by a vulnerability in the kernel known as TCP SACK PANIC. The vulnerability could allow a remote attacker to cause a denial of service condition. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing further ...
Titel
SSA-641963 V1.0: Remote Code Execution Vulnerability in Multiple SIMATIC Software Products
Veröffentlicht
13. Juli 2021 02:00
Text
Multiple SIMATIC Software products are affected by a vulnerability that could allow an attacker to manipulate project files and remotely execute code. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not ...
Titel
SSA-661034 V1.0: Incorrect Permission Assignment in Multiple SIMATIC Software Products
Veröffentlicht
13. Juli 2021 02:00
Text
Multiple SIMATIC software products are affected by a vulnerability that could allow an attacker to change the content of certain metafiles and subsequently manipulate parameters or behaviour of devices configured by the affected software products. Siemens has released an update for the SIMATIC STEP 7 V5.X and recommends to update ...
Titel
SSA-675303 V1.0: WIBU Systems CodeMeter Runtime Vulnerabilities in Siemens Products
Veröffentlicht
13. Juli 2021 02:00
Text
WIBU Systems disclosed two vulnerabilities and a new release version of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens products for license management. The vulnerabilities are described in the section “Vulnerability Classification” below and got assigned the CVE IDs CVE-2021-20093 and CVE-2021-20094. Successful exploitation of ...
Titel
SSA-729965 V1.0: TLS Certificate Validation Vulnerability in SINUMERIK Integrate Operate Client
Veröffentlicht
13. Juli 2021 02:00
Text
The latest update for SINUMERIK Integrate Operate Client fixes a vulnerability that could allow an attacker to spoof any SSL server certificate and conduct man-in-the-middle attacks. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available
Titel
SSA-772220 V1.0: OpenSSL Vulnerabilities in Industrial Products
Veröffentlicht
13. Juli 2021 02:00
Text
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < k, that allows an unauthenticated attacker to cause a Denial-of-Service (DoS) if a a maliciously crafted renegotiation message is sent. Siemens is preparing updates and recommends countermeasures for products where updates are not, or not ...
Titel
SSA-560465 V1.0: DHCP Client Vulnerability in VxWorks-based Industrial Products
Veröffentlicht
13. Juli 2021 02:00
Text
Various industry products are affected by a DHCP client vulnerability in Wind River VxWorks, that could allow an attacker to cause a heap-based buffer overflow. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
Titel
SSA-434536 V1.0: Memory Protection Bypass Vulnerability in SINUMERIK ONE and SINUMERIK MC
Veröffentlicht
13. Juli 2021 02:00
Text
SINUMERIK ONE and SINUMERIK MC products are affected by a memory protection bypass vulnerability in the integrated S7-1500 CPU that could allow an attacker to write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks on the CPU. Siemens is preparing updates and ...
Titel
SSA-173615 V1.0: Multiple PAR and ASM File Parsing Vulnerabilities in Solid Edge
Veröffentlicht
13. Juli 2021 02:00
Text
Siemens has released version SE2021MP5 for Solid Edge to fix multiple heap based buffer overflow vulnerabilities that could be triggered when the application read files in PAR or ASM file formats. If a user is tricked to open a malicious file with the affected application, this could lead to a ...
Titel
SSA-209268 V1.0: Multiple JT File Parsing Vulnerabilities in JT Utilities before V13.0.2.0
Veröffentlicht
13. Juli 2021 02:00
Text
Siemens has released version V13.0.2.0 for JT Utilities to fix multiple vulnerabilities that could be triggered when reading JT files. Siemens recommends to update to the latest version, which contains solutions to all the vulnerabilities listed in this advisory. Standing recommendation is to avoid opening of untrusted files from unknown ...
Titel
SSA-352521 V1.0: Access Check Bypass Vulnerability in Mendix
Veröffentlicht
13. Juli 2021 02:00
Text
An incorrect authorization check in Mendix applications could allow an attacker to bypass write permissions to attributes of objects under certain circumstances. Mendix has released an update for Mendix and recommends to update to the latest version.
Titel
SSA-373591 V1.0: Buffer Overflow Vulnerability in RUGGEDCOM ROS Devices
Veröffentlicht
13. Juli 2021 02:00
Text
The latest update for RUGGEDCOM ROS devices fixes a buffer overflow vulnerability in the third party component that could allow an attacker with network access to an affected device to cause a remote code execution condition. Siemens has released updates for the affected products and recommends to update to the ...
Titel
SSA-622535 V1.0: Multiple Vulnerabilities in Teamcenter Active Workspace
Veröffentlicht
13. Juli 2021 02:00
Text
Multiple vulnerabilities affecting Teamcenter Active Workspace could lead to sensitive information disclosure and reflected cross site scripting. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-599968 V1.0: Denial-of-Service Vulnerability in Profinet Devices
Veröffentlicht
13. Juli 2021 02:00
Text
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of Profinet Discovery and Configuration Protocol (DCP) reset packets is sent to the affected devices. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens ...
Titel
SSA-913875 V1.0: Frame Aggregation and Fragmentation Vulnerabilities in 802.11
Veröffentlicht
13. Juli 2021 02:00
Text
Twelve vulnerabilities in the implementation of frame aggregation and fragmentation of the 802.11 standard, under the name of FragAttacks, have been published. Successful exploitation of these vulnerabilities could allow an attacker within Wi-Fi range to forge encrypted frames, which could result in sensitive data disclosure and possibly traffic manipulation. The ...

Letzte Updates

BOSCH PSIRT
15.05.2024
SIEMENS CERT
14.05.2024
US CERT
10.05.2024
US CERT (ICS)
16.05.2024

Nach Quelle

Archiv

2024
2023
2022
2021
2020
2019
2018
2017

Feeds