• 1 (current)
  • 2
  • 3
Mittwoch, 31.05.2023
Titel
Possible damage of secure element in Bosch IP cameras
Veröffentlicht
31. Mai 2023 02:00
Text

BOSCH-SA-435698-BT: Due to an error in the software interface to the secure element chip on the cameras, the chip can be **permanently damaged** leading to an unusable camera when enabling the Stream security option (signing of the video stream) on Bosch CPP13 and CPP14 cameras. The default setting for this ...

Donnerstag, 25.05.2023
Titel
Moxa MXsecurity Series
Veröffentlicht
25. Mai 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Moxa Equipment: MXsecurity Series Vulnerabilities: Command Injection and Use of Hard-Coded Credentials 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an unauthorized user to bypass authentication or to execute arbitrary commands on the device. 3. TECHNICAL ...
Mittwoch, 24.05.2023
Titel
Unrestricted SSH port forwarding in BVMS
Veröffentlicht
24. Mai 2023 02:00
Text

BOSCH-SA-025794-BT: The Bosch Video Management System is using SSH server that does not restrict a port forwarding requested by an authenticated SSH client. An authenticated SSH client can request a connection which is forwarded by the BVMS SSH server to a resource within the trusted internal network, which is normally ...

Titel
.NET Remote Code Execution Vulnerability in BVMS, BIS and AMS
Veröffentlicht
24. Mai 2023 02:00
Text

BOSCH-SA-110112-BT: The Bosch Video Management System (BVMS), the Bosch Access Management System (AMS), and the Bosch Building Integration System (BIS) are using a vulnerable version of the Microsoft .NET package System.Text.Encodings.Web. The System.Text.Encodings.Web is a NuGet package from Microsoft, and Microsoft has published an advisory to provide information about a ...

Titel
Vulnerability in Wiegand card data interpretation
Veröffentlicht
24. Mai 2023 02:00
Text

BOSCH-SA-391095-BT: Bosch Access Control products AMC2-4WCF and AMC2-2WCF have a firmware bug which may lead to misinterpretation of access card data that is sent from a Wiegand reader. This may in turn lead to granting physical access to an unauthorized person. This vulnerability affects only products with Wiegand interface, i.e., ...

Dienstag, 23.05.2023
Titel
People's Republic of China State-Sponsored Cyber Actor Living off the Land to Evade Detection
Veröffentlicht
23. Mai 2023 20:06
Text
Summary The United States and international cybersecurity authorities are issuing this joint Cybersecurity Advisory (CSA) to highlight a recently discovered cluster of activity of interest associated with a People’s Republic of China (PRC) state-sponsored cyber actor, also known as Volt Typhoon. Private sector partners have identified that this activity affects ...
Titel
Mitsubishi Electric MELSEC Series CPU module
Veröffentlicht
23. Mai 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Corporation Equipment: MELSEC Series CPU module Vulnerabilities: Classic Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service condition or execute malicious code on a target product ...
Titel
Hitachi Energy’s AFS65x, AFS67x, AFR67x and AFF66x Products
Veröffentlicht
23. Mai 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: AFS65x, AFS67x, AFR67x and AFF66x series products Vulnerabilities: Use After Free 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information or lead to a Denial-of-Service (DoS). 3. TECHNICAL ...
Titel
Hitachi Energy’s RTU500 Series Product
Veröffentlicht
23. Mai 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: RTU500 Series Vulnerabilities: Type Confusion, Observable Timing Discrepancy, Out-of-bounds Read, Infinite Loop, Classic Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to crash the device being accessed or cause ...
Donnerstag, 18.05.2023
Titel
Rockwell Automation FactoryTalk Diagnostics (Update B)
Veröffentlicht
18. Mai 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Rockwell Automation Equipment: FactoryTalk Diagnostics Vulnerabilities: Deserialization of Untrusted Data 2. UPDATE OR REPOSTED INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-20-051-02-Rockwell Automation FactoryTalk Diagnostics (Update A) that was published February ...
Titel
Johnson Controls OpenBlue Enterprise Manager Data Collector
Veröffentlicht
18. Mai 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Johnson Controls Inc. Equipment: OpenBlue Enterprise Manager Data Collector Vulnerabilities: Improper Authentication, Exposure of Sensitive Information to an Unauthorized Actor 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker, under certain circumstances, to make application ...
Titel
Hitachi Energy’s MicroSCADA Pro/X SYS600 Products
Veröffentlicht
18. Mai 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 6.7 ATTENTION: Public exploits are available Vendor: Hitachi Energy Equipment: MicroSCADA Pro/X SYS600 Products Vulnerabilities: Permissions, Privileges, and Access Controls 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code on the affected product. 3. TECHNICAL DETAILS 3.1 AFFECTED ...
Titel
Carlo Gavazzi Powersoft
Veröffentlicht
18. Mai 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available Vendor: Carlo Gavazzi Equipment: Powersoft Vulnerabilities: Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to access and retrieve any file from the server. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The ...
Titel
Mitsubishi Electric MELSEC WS Series
Veröffentlicht
18. Mai 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: WS0-GETH00200 Vulnerabilities: Active Debug Code 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to bypass authentication and log in by connecting to the module via telnet to reset the module or, ...
Dienstag, 16.05.2023
Titel
Rockwell Automation FactoryTalk Vantagepoint
Veröffentlicht
16. Mai 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 7.1 ATTENTION: Exploitable remotely Vendor: Rockwell Automation Equipment: FactoryTalk Vantagepoint Vulnerabilities: Insufficient Verification of Data Authenticity 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to impersonate an existing user or execute a cross site request forgery (CSRF) attack. 3. TECHNICAL DETAILS ...
Titel
Rockwell ArmorStart
Veröffentlicht
16. Mai 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 7.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Equipment: ArmorStart Vulnerabilities: Improper Input Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow a malicious user to view and modify sensitive data or make the web page unavailable. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS ...
Titel
Snap One OvrC Cloud
Veröffentlicht
16. Mai 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Snap One Equipment: OvrC Cloud, OvrC Pro Devices Vulnerabilities: Improper Input Validation, Observable Response Discrepancy, Improper Access Control, Cleartext Transmission of Sensitive Information, Insufficient Verification of Data Authenticity, Open Redirect, Use of Hard-coded Credentials, Hidden Functionality 2. RISK ...
Montag, 15.05.2023
Titel
#StopRansomware: BianLian Ransomware Group
Veröffentlicht
15. Mai 2023 18:29
Text
Summary Note: This joint Cybersecurity Advisory (CSA) is part of an ongoing #StopRansomware effort to publish advisories for network defenders that detail various ransomware variants and ransomware threat actors. These #StopRansomware advisories include recently and historically observed tactics, techniques, and procedures (TTPs) and indicators of compromise (IOCs) to help organizations ...
Donnerstag, 11.05.2023
Titel
Rockwell Automation Kinetix 5500
Veröffentlicht
11. Mai 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 9.4 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: Kinetix 5500 EtherNet/IP Servo Drive Vulnerabilities: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could create a denial-of-service condition or allow attackers unauthorized access to the device. 3. TECHNICAL DETAILS 3.1 AFFECTED ...
Titel
Siemens SCALANCE LPE9403
Veröffentlicht
11. Mai 2023 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 1. EXECUTIVE SUMMARY CVSS v3 ...
Titel
SDG PnPSCADA
Veröffentlicht
11. Mai 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: SDG Technologies Equipment: PnPSCADA Vulnerabilities: SQL Injection 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to interact with the database and retrieve critical data. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of ...
Titel
BirdDog Cameras and Encoders
Veröffentlicht
11. Mai 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 8.4 ATTENTION: Exploitable remotely/low attack complexity Vendor: BirdDog Equipment: STUDIO R3, 4K QUAD, MINI, A300 EYES Vulnerabilities: Cross-Site Request Forgery, Use of Hard-Coded Credentials 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to remotely execute code or obtain unauthorized access to ...
Titel
Teltonika Remote Management System and RUT Model Routers
Veröffentlicht
11. Mai 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Teltonika Equipment: Remote Management System and RUT model routers Vulnerabilities: Observable Response Discrepancy, Improper Authentication, Server-Side Request Forgery, Cross-site Scripting, Inclusion of Web Functionality from an Untrusted Source, External Control of System of Configuration Setting, OS Command Injection ...
Titel
Rockwell Automation PanelView 800
Veröffentlicht
11. Mai 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: PanelView 800 Vulnerabilities: Out-of-bounds Write, Out-of-bounds Read 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of PanelView 800, a graphics terminal, ...
Titel
Siemens SINEC NMS Third-Party
Veröffentlicht
11. Mai 2023 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 1. EXECUTIVE SUMMARY CVSS v3 ...
  • 1 (current)
  • 2
  • 3

Letzte Updates

BOSCH PSIRT
20.03.2024
CODESYS
28.06.2023
SIEMENS CERT
26.03.2024
US CERT
26.02.2024
US CERT (ICS)
26.03.2024

Nach Quelle

Archiv

2024
2023
2022
2021
2020
2019
2018
2017

Feeds