• 1 (current)
  • 2
  • 3
Donnerstag, 29.09.2022
Titel
Delta Electronics DOPSoft (Update B)
Veröffentlicht
29. September 2022 16:30
Text
This updated advisory is a follow-up to the advisory update titled ICSA-21-184-04 Delta Electronics DOPSoft (Update A) that was published July 27, 2021 to the ICS webpage on cisa.gov/ics. This advisory contains mitigations for Out-of-bounds Read vulnerabilities in Delta Electronics DOPSoft software.
Titel
ARC Informatique PcVue (Update A)
Veröffentlicht
29. September 2022 16:20
Text
This updated advisory is a follow-up to the advisory update titled ICSA-22-235-01 ARC Informatique PcVue that was published August 23, 2022 to the ICS webpage on cisa.gov/ics. This advisory contains mitigations for a Cleartext Storage of Sensitive Information vulnerability in various components of ARC Informatique products.
Titel
Hitachi Energy MicroSCADA Pro X SYS600
Veröffentlicht
29. September 2022 16:05
Text
This advisory contains mitigations for NULL Pointer Dereference and Infinite Loop vulnerabilities in Hitachi Energy MicroSCADA Pro/X SYS600 products.
Dienstag, 27.09.2022
Titel
Hitachi Energy AFS660/AFS665
Veröffentlicht
27. September 2022 16:20
Text
This advisory contains mitigations for an Improper Input Validation vulnerability in Hitachi Energy AFS660 and AFS665 industrial switches.
Titel
Rockwell Automation ThinManager ThinServer
Veröffentlicht
27. September 2022 16:00
Text
This advisory contains mitigations for a Heap-based Buffer Overflow vulnerability in Rockwell Automation ThinManager ThinServer, a thin client and remote desktop protocol (RDP) server management software.
Donnerstag, 22.09.2022
Titel
Mitsubishi Electric Factory Automation Engineering Software (Update D)
Veröffentlicht
22. September 2022 16:10
Text
This updated advisory is a follow-up to the advisory update titled ICSA-20-212-02 Mitsubishi Electric Factory Automation Engineering Software (Update C) that was published July 28, 2022, to the ICS webpage on cisa.gov/ics.This advisory contains mitigations for a Permission Issues vulnerability in versions of Mitsubishi Electric Factory Automation Engineering Software products.
Titel
Mitsubishi Electric Multiple Products (Update E)
Veröffentlicht
22. September 2022 16:00
Text
This updated advisory is a follow-up to the advisory update titled ICSA-20-245-01 Mitsubishi Electric Multiple Products (Update D) that was published May 31, 2022 to the ICS webpage on cisa.gov/ics. This advisory contains mitigations for a Predictable Exact Value from Previous Values vulnerabilit in versions of several Mitsubishi Electric products.
Titel
AA22-265A: Control System Defense: Know the Opponent
Veröffentlicht
22. September 2022 14:55
Text
Original release date: September 22, 2022SummaryTraditional approaches to securing OT/ICS do not adequately address current threats. Operational technology/industrial control system (OT/ICS) assets that operate, control, and monitor day-to-day critical infrastructure and industrial processes continue to be an attractive target for malicious cyber actors. These cyber actors, including advanced persistent threat ...
Mittwoch, 21.09.2022
Titel
AA22-264A: Iranian State Actors Conduct Cyber Operations Against the Government of Albania
Veröffentlicht
21. September 2022 19:00
Text
Original release date: September 21, 2022SummaryThe Federal Bureau of Investigation (FBI) and the Cybersecurity and Infrastructure Security Agency (CISA) are releasing this joint Cybersecurity Advisory to provide information on recent cyber operations against the Government of Albania in July and September. This advisory provides a timeline of activity observed, from ...
Titel
A22-264A: Iranian State Actors Conduct Cyber Operations Against the Government of Albania
Veröffentlicht
21. September 2022 19:00
Text
Original release date: September 21, 2022SummaryThe Federal Bureau of Investigation (FBI) and the Cybersecurity and Infrastructure Security Agency (CISA) are releasing this joint Cybersecurity Advisory to provide information on recent cyber operations against the Government of Albania in July and September. This advisory provides a timeline of activity observed, from ...
Titel
Information Disclosure in VIDEOJET Decoder and Operator Client application in BVMS
Veröffentlicht
21. September 2022 02:00
Text

BOSCH-SA-464066-BT: BVMS Operator Client application or the VIDEOJET Decoder VJD-7513 may receive an *unencrypted* live-stream from a camera which allows a man-in-the-middle attacker to compromise the confidential video streams.This happens only in combination with cameras of platform CPP13 or CPP14.x when encrypted UDP connection is configured. Please be aware that ...

Dienstag, 20.09.2022
Titel
Hitachi Energy PROMOD IV
Veröffentlicht
20. September 2022 16:35
Text
This advisory contains mitigations for an Improper Access Control vulnerability in PROMOD IV.
Titel
Hitachi Energy AFF660/665 Series
Veröffentlicht
20. September 2022 16:30
Text
This advisory contains mitigations for a Stack-base Buffer Overflow vulnerability in versions of Hitachi Energy AFF660/665 Firewall software.
Titel
Medtronic NGP 600 Series Insulin Pumps
Veröffentlicht
20. September 2022 16:25
Text
This advisory contains mitigations for a Protection Mechanism Failure vulnerability in versions of Medtronic NGP 600 Series Insulin Pumps and accessory components.
Titel
Dataprobe iBoot-PDU
Veröffentlicht
20. September 2022 16:20
Text
This advisory contains mitigations for OS Command Injection, Path Traversal, Exposure of Sensitive Information to an Unauthorized Actor, Improper Access Control, Improper Authorization, Incorrect Authorization, and SSRF vulnerabilities in versions of Dataprobe iBoot-PDU FW products.
Titel
Host Engineering Communications Module
Veröffentlicht
20. September 2022 16:15
Text
This advisory contains mitigations for a Stack-based Buffer overflow vulnerability in versions of Host Engineering H0-ECOM100 Communications Module products.
Titel
AutomationDirect DirectLOGIC with Ethernet (Update A)
Veröffentlicht
20. September 2022 16:10
Text
This updated advisory is a follow-up to the original advisory titled ICSA-22.167-03 AutomationDirect DirectLOGIC with Ethernet that was published June 16, 2022, on the ICS webpage on cisa.gov/ICS. This advisory contains mitigations for Uncontrolled Resource Consumption and Cleartext Transmission of Sensitive Information vulnerabilities in versions of AutomationDirect DirectLOGIC with Ethernet ...
Titel
AutomationDirect DirectLOGIC with Serial Communication (Update A)
Veröffentlicht
20. September 2022 16:05
Text
This updated advisory is a follow-up to the original advisory titled ICSA-22.167-02 AutomationDirect DirectLOGIC with Serial Communication that was published June 16, 2022, on the ICS webpage on cisa.gov/ICS. This advisory contains mitigations for a Cleartext Transmission of Sensitive Information vulnerability in versions of AutomationDirect DirectLOGIC with Serial Communication products.
Titel
MiCODUS MV720 GPS tracker (Update A)
Veröffentlicht
20. September 2022 16:00
Text
This updated advisory is a follow-up to the original advisory titled ICSA-22-200-01 MiCODUS MV720 GPS tracker that was published July 19, 2022, on the ICS webpage on cisa.gov/ICS. This advisory contains mitigations for Use of Hard-coded Credentials, Improper Authentication, Cross-site Scripting, and Authorization Bypass Through User-controlled Key vulnerabilities in versions ...
Donnerstag, 15.09.2022
Titel
Siemens Mobility CoreShield OWG Software
Veröffentlicht
15. September 2022 16:50
Text
This advisory contains mitigations for an Improper Access Control vulnerability in versions of Siemens CoreShield One-Way Gateway (OWG) Software.
Titel
Siemens Simcenter Femap and Parasolid
Veröffentlicht
15. September 2022 16:45
Text
This advisory contains mitigations for Multiple File Parsing vulnerabilities in Siemens Simcenter Femap and Parasolid products.
Titel
Siemens Industrial Products Intel CPUs (Update F)
Veröffentlicht
15. September 2022 16:38
Text
This updated advisory is a follow-up to the advisory update titled ICSA-21-222-05 Siemens Industrial Products Intel CPU (Update E) that was published August 11, 2022, to the ICS webpage on www.cisa.gov/ics. This advisory contains mitigations for a Missing Encryption of Sensitive Data vulnerability in versions of Siemens Industrial Products Intel ...
Titel
Siemens RUGGEDCOM ROS (Update A)
Veröffentlicht
15. September 2022 16:25
Text
This updated advisory is a follow-up to the original advisory titled ICSA-19-344-03 Siemens RUGGEDCOM ROS that was published December 10, 2019, on the ICS webpage on cisa.gov/ICS. This advisory contains mitigations for Improper Restriction of Operations within the Bounds of a Memory Buffer and Resource Management Errors vulnerabilities in multiple ...
Titel
Simcenter Femap and Parasolid (Update B)
Veröffentlicht
15. September 2022 16:20
Text
This updated advisory is a follow-up to the original advisory titled ICSA-22-195-09 Simcenter Femap and Parasolid (Update A) that was published July 14, 2022, on the ICS webpage on cisa.gov/ics. This advisory contains mitigations for an Out-of-bounds Read vulnerability Simcenter Femap, an advanced simulation application, and Parasolid, a 3D geometric ...
Titel
Siemens OpenSSL Affected Industrial Products (Update C)
Veröffentlicht
15. September 2022 16:10
Text
This updated advisory is a follow-up to the original advisory titled ICSA-22-167-14 Siemens OpenSSL Affected Industrial Products (Update B) that was published August 18, 2022, on the ICS webpage on cisa.gov/ics. This advisory contains mitigations for an Infinite Loop vulnerability in multiple Siemens industrial products.