• 1 (current)
  • 2
Dienstag, 30.01.2024
Titel
Emerson Rosemount GC370XA, GC700XA, GC1500XA
Veröffentlicht
30. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely Vendor: Emerson Equipment: Rosemount GC370XA, GC700XA, GC1500XA Vulnerabilities: Command Injection, Improper Authentication, Improper Authorization 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an unauthenticated attacker with network access to run arbitrary commands, access sensitive information, cause a ...
Titel
Rockwell Automation FactoryTalk Service Platform
Veröffentlicht
30. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk Service Platform Vulnerability: Improper Verification of Cryptographic Signature 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to retrieve user information and modify settings without any authentication. 3. TECHNICAL ...
Titel
Mitsubishi Electric MELSEC WS Series Ethernet Interface Module
Veröffentlicht
30. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely Vendor: Mitsubishi Electric Equipment: MELSEC WS Series Vulnerability: Authentication Bypass by Capture-replay 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthorized attacker to login to the modules and disclose or tamper with the programs and parameters ...
Titel
Rockwell Automation ControlLogix and GuardLogix
Veröffentlicht
30. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: ControlLogix, GuardLogix Vulnerability: Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to crash the device by exploiting a ...
Titel
Rockwell Automation LP30/40/50 and BM40 Operator Interface
Veröffentlicht
30. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: LP30, LP40, LP50, and BM40 Operator Panels Vulnerability: Improper Validation of Consistency within Input, Out-of-bounds Write, Stack-based Buffer Overflow, Untrusted Pointer Dereference 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an ...
Titel
Hitron Systems Security Camera DVR
Veröffentlicht
30. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available/known public exploitation Vendor: Hitron Systems Equipment: DVR Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to affect the availability of the product through exploitation of an ...
Donnerstag, 25.01.2024
Titel
SystemK NVR 504/508/516
Veröffentlicht
25. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available Vendor: SystemK Equipment: NVR 504/508/516 Vulnerability: Command Injection 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute commands with root privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following ...
Titel
MachineSense FeverWarn
Veröffentlicht
25. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: MachineSense LLC. Equipment: MachineSense FeverWarn Vulnerabilities: Missing Authentication for Critical Function, Use of Hard-coded Credentials, Improper Access Control, OS Command Injection, Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful ...
Titel
Opteev MachineSense FeverWarn
Veröffentlicht
25. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: MachineSense LLC. Equipment: MachineSense FeverWarn Vulnerabilities: Missing Authentication for Critical Function, Use of Hard-coded Credentials, Improper Access Control, OS Command Injection, Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful ...
Dienstag, 23.01.2024
Titel
Lantronix XPort
Veröffentlicht
23. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.7 ATTENTION: Low attack complexity Vendor: Lantronix Equipment: XPort Vulnerability: Weak Encoding for Password 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to obtain credentials. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of XPort, a device server ...
Titel
Crestron AM-300
Veröffentlicht
23. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.4 ATTENTION: Low attack complexity Vendor: Crestron Equipment: AM-300 Vulnerability: OS Command Injection 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to escalate their privileges to root-level access. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Crestron AirMedia Presentation ...
Titel
Westermo Lynx 206-F2G
Veröffentlicht
23. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Westermo Equipment: Lynx 206-F2G Vulnerabilities: Cross-site Scripting, Code Injection, Cross-Origin Resource Sharing, Cleartext Transmission of Sensitive Information, Cross-Site Request Forgery 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to access the web ...
Titel
APsystems Energy Communication Unit (ECU-C) Power Control Software
Veröffentlicht
23. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable via adjacent network / low attack complexity Vendor: APsystems Equipment: Energy communication Unit (ECU-C) Power Control Software Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to access sensitive data and execute specific ...
Titel
Voltronic Power ViewPower Pro
Veröffentlicht
23. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/Low attack complexity Vendor: Voltronic Power Equipment: ViewPower Pro Vulnerabilities: Deserialization of Untrusted Data, Missing Authentication for Critical Function, Exposed Dangerous Method or Function, OS Command Injection 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to ...
Donnerstag, 18.01.2024
Titel
AVEVA PI Server
Veröffentlicht
18. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: AVEVA Equipment: PI Server Vulnerabilities: Improper Check or Handling of Exceptional Conditions, Missing Release of Resource after Effective Lifetime 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to crash the product being ...
Dienstag, 16.01.2024
Titel
SEW-EURODRIVE MOVITOOLS MotionStudio
Veröffentlicht
16. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.5 ATTENTION: Low attack complexity Vendor: SEW-EURODRIVE Equipment: MOVITOOLS MotionStudio Vulnerability: Improper Restriction of XML EXTERNAL Entity Reference 2. RISK EVALUATION Successful exploitation of this vulnerability could result in open access to file information. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions ...
Titel
Integration Objects OPC UA Server Toolkit
Veröffentlicht
16. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Integration Objects Equipment: OPC UA Server Toolkit Vulnerability: Improper Output Neutralization for Logs 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a remote attacker to add content to the log file. 3. TECHNICAL DETAILS ...
Freitag, 12.01.2024
Titel
Known Indicators of Compromise Associated with Androxgh0st Malware
Veröffentlicht
12. Januar 2024 18:13
Text
SUMMARY The Federal Bureau of Investigation (FBI) and the Cybersecurity and Infrastructure Security Agency (CISA) are releasing this joint Cybersecurity Advisory (CSA) to disseminate known indicators of compromise (IOCs) and tactics, techniques, and procedures (TTPs) associated with threat actors deploying Androxgh0st malware. Multiple, ongoing investigations and trusted third party reporting ...
Donnerstag, 11.01.2024
Titel
Schneider Electric Easergy Studio
Veröffentlicht
11. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Schneider Electric Equipment: Easergy Studio Vulnerability: Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to gain full control of a workstation. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following ...
Titel
Rapid Software LLC Rapid SCADA
Veröffentlicht
11. Januar 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.6 ATTENTION: Exploitable remotely, low attack complexity Vendor: Rapid Software LLC Equipment: Rapid SCADA Vulnerabilities: Path Traversal, Relative Path Traversal, Local Privilege Escalation through Incorrect Permission Assignment for Critical Resource, Open Redirect, Use of Hard-coded Credentials, Plaintext Storage of a Password, Generation of ...
Titel
Siemens SIMATIC
Veröffentlicht
11. Januar 2024 13:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Dienstag, 09.01.2024
Titel
SSA-999588 V1.1 (Last Update: 2024-01-09): Multiple Vulnerabilities in User Management Component (UMC) before V2.11.2
Veröffentlicht
9. Januar 2024 01:00
Text
Siemens User Management Component (UMC) before V2.11.2 is affected by multiple vulnerabilities where the most severe could lead to a restart of the UMC server. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures ...
Titel
SSA-844761 V1.3 (Last Update: 2024-01-09): Multiple Vulnerabilities in SiNVR/SiVMS Video Server
Veröffentlicht
9. Januar 2024 01:00
Text
The Video Server application in SiNVR/SiVMS solutions contains five vulnerabilities involving information disclosure (CVE-2019-19291, CVE-2019-19299), path traversal (CVE-2019-19296, CVE-2019-19297), and denial-of-service (CVE-2019-19298). PKE has released updates of the application that fixes the reported vulnerabilities, except for CVE-2019-19299. This update is not available under the former Siemens OEM brand name SiNVR. ...
Titel
Open Port 8899 in BCC Thermostat Product
Veröffentlicht
9. Januar 2024 01:00
Text

BOSCH-SA-473852: A network port 8899 is always open in BCC101/BCC102/BCC50 thermostat products, which allows an un-authencated connection from a local WiFi network.

Titel
SSA-398330 V1.1 (Last Update: 2024-01-09): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1
Veröffentlicht
9. Januar 2024 01:00
Text
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not ...
  • 1 (current)
  • 2

Letzte Updates

BOSCH PSIRT
20.03.2024
CODESYS
28.06.2023
SIEMENS CERT
19.04.2024
US CERT
17.04.2024
US CERT (ICS)
25.04.2024

Nach Quelle

Archiv

2024
2023
2022
2021
2020
2019
2018
2017

Feeds