Dienstag, 13.03.2018
Titel
GE Medical Devices Vulnerability
Veröffentlicht
13. März 2018 15:00
Text
This medical device advisory was originally posted to the HSIN ICS-CERT library on February 6, 2018, and is being released to the NCCIC/ICS-CERT website. This advisory contains mitigations for an improper authentication vulnerability in several GE medical devices.
Donnerstag, 08.03.2018
Titel
Siemens SIPROTEC 4, SIPROTEC Compact, DIGSI 4, and EN100 Ethernet Module
Veröffentlicht
8. März 2018 16:05
Text
This advisory includes mitigations for missing authentication for critical function, and inadequate encryption strength vulnerabilities in Siemens' SIPROTEC 4, SIPROTEC Compact, DIGSI 4, and EN100 Ethernet module.
Titel
Siemens SIPROTEC 4, SIPROTEC Compact, and Reyrolle Devices using the EN100 Ethernet Communication Module Extension
Veröffentlicht
8. März 2018 16:00
Text
This advisory includes mitigation details for a missing authentication for critical function vulnerability in the Siemens SIPROTEC 4, SIPROTEC Compact, and Reyrolle devices using the EN100 Ethernet communication module extension.
Titel
SSA-203306 (Last Update: 2018-03-08): Password Vulnerabilities in SIPROTEC 4 and SIPROTEC Compact Relay Families
Veröffentlicht
8. März 2018 01:00
Text
SIPROTEC 4 and SIPROTEC Compact devices could allow access authorization passwords to be reconstructed or overwritten via engineering mechanisms that involve DIGSI 4 and EN100 Ethernet communication modules. Siemens has released updates for several affected products, is working on updates for the remaining affected products, and recommends specific countermeasures until ...
Titel
SSA-845879 (Last Update: 2018-03-08): Firmware Downgrade Vulnerability in EN100 Ethernet Communication Module for SIPROTEC 4, SIPROTEC Compact and Reyrolle
Veröffentlicht
8. März 2018 01:00
Text
The EN100 Ethernet communication module, which is an optional extension for SIPROTEC 4, SIPROTEC Compact and Reyrolle devices, allows an unauthenticated upload of firmware updates to the communication module in affected versions. Siemens has released updates for several affected products, is working on updates for the remaining affected products, and ...
Dienstag, 06.03.2018
Titel
Hirschmann Automation and Control GmbH Classic Platform Switches
Veröffentlicht
6. März 2018 16:10
Text
This advisory includes mitigation recommendations for session fixation, information exposure through query strings in GET request, cleartext transmission of sensitive information, inadequate encryption strength, and improper restriction of excessive authentication attempts vulnerabilities in the Hirschmann Automation and Control GmbH Classic Platform Switches.
Titel
Schneider Electric SoMove Software and DTM Software Components
Veröffentlicht
6. März 2018 16:05
Text
This advisory includes mitigations for an uncontrolled search path element vulnerability in the Schneider Electric SoMove software and DTM software components.
Titel
Eaton ELCSoft
Veröffentlicht
6. März 2018 16:00
Text
This advisory includes mitigation details for an improper input validation vulnerability in the Eaton ELCSoft programming software.
Titel
SSA-293562 (Last Update: 2018-03-06): Vulnerabilities in Industrial Products
Veröffentlicht
6. März 2018 01:00
Text
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct Layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released updates for ...
Donnerstag, 01.03.2018
Titel
Siemens SIMATIC, SIMOTION, and SINUMERIK
Veröffentlicht
1. März 2018 16:10
Text
This advisory contains mitigation details for stack-based buffer overflow and permissions, privileges, and access controls vulnerabilities in the Siemens' SIMATIC, SIMOTION, and SINUMERIK Industrial PCs.
Titel
Moxa OnCell G3100-HSPA Series
Veröffentlicht
1. März 2018 16:05
Text
This advisory contains mitigation details for reliance on cookies without validation and integrity checking, improper handling of length parameter inconsistency, and NULL pointer dereference vulnerabilities in the Moxa OnCell G3100-HSPA Series IP gateway.
Titel
Delta Electronics Delta Industrial Automation DOPSoft
Veröffentlicht
1. März 2018 16:00
Text
This advisory contains mitigation details for a stack-based buffer overflow vulnerability in the Delta Electronics Delta Industrial Automation DOPSoft human machine interface.