• 1
  • 2 (current)
Dienstag, 12.02.2019
Titel
SSA-346262 (Last Update: 2019-02-12): Denial-of-Service in Industrial Products
Veröffentlicht
12. Februar 2019 01:00
Text
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates ...
Titel
SSA-179516 (Last Update: 2019-02-12): OpenSSL Vulnerability in Industrial Products
Veröffentlicht
12. Februar 2019 01:00
Text
A vulnerability in OpenSSL affects several Siemens industrial products. Siemens has released updates for some affected products and is working on updates for others.
Titel
SSA-284673 (Last Update: 2019-02-12): Vulnerability in Industrial Products
Veröffentlicht
12. Februar 2019 01:00
Text
Several industrial devices are affected by a vulnerability that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct Layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released updates for ...
Titel
SSA-268644 (Last Update: 2019-02-12): Spectre-NG (Variants 3a and 4) Vulnerabilities in Industrial Products
Veröffentlicht
12. Februar 2019 01:00
Text
Security researchers published information on vulnerabilities known as Spectre-NG (Variants 3a and 4). These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Industrial Products include affected processors and are affected by the vulnerabilities.
Donnerstag, 07.02.2019
Titel
Siemens SICAM A8000 RTU Series
Veröffentlicht
7. Februar 2019 16:05
Text
This advisory includes mitigations for an uncaught exception vulnerability reported in the Siemens SICAM A8000RTU product.
Titel
Siemens EN100 Ethernet Module
Veröffentlicht
7. Februar 2019 16:00
Text
This advisory provides mitigation recommendations for an improper input validation vulnerability reported in the Siemens EN100 Ethernet module for the SWT 3000 management platform.
Dienstag, 05.02.2019
Titel
AVEVA InduSoft Web Studio and InTouch Edge HMI
Veröffentlicht
5. Februar 2019 16:20
Text
This advisory provides mitigation recommendations for Missing Authentication for Critical Function and Resource Injection vulnerabilities reported in the AVEVA InduSoft Web Studio and InTouch Edge HMI (formerly InTouch Machine Edition) applications.
Titel
Rockwell Automation EtherNet/IP Web Server Modules
Veröffentlicht
5. Februar 2019 16:15
Text
This advisory includes mitigations for an improper input validation vulnerability reported in the Rockwell Automation EtherNet/IP Web Server Modules.
Titel
Siemens SIMATIC S7-1500 CPU
Veröffentlicht
5. Februar 2019 16:05
Text
This advisory provides mitigation recommendations for uncontrolled resource consumption vulnerabilities reported in Siemens' SIMATIC SV-1500 CPU.
Titel
Kunbus PR100088 Modbus Gateway
Veröffentlicht
5. Februar 2019 16:00
Text
This advisory provides mitigation recommendations for improper authentication, missing authentication for critical function, and improper input validation vulnerabilities reported in the Kunbus PR100088 Modbus gateway.
Titel
Kunbus PR100088 Modbus Gateway (Update A)
Veröffentlicht
5. Februar 2019 16:00
Text
This updated advisory is a follow-up to the original advisory titled ICSA-19-036-05 Kunbus PR100088 Modbus Gateway that was published February 5, 2019, on the NCCIC/ICS-CERT website. This advisory provides mitigation recommendations for improper authentication, missing authentication for critical function, and improper input validation vulnerabilities reported in the Kunbus PR100088 Modbus ...
  • 1
  • 2 (current)

Letzte Updates

BOSCH PSIRT
19.07.2024
SIEMENS CERT
22.07.2024
US CERT
24.07.2024
US CERT (ICS)
25.07.2024

Nach Quelle

Archiv

2024
2023
2022
2021
2020
2019
2018
2017

Feeds