• 1
  • 2 (current)
  • 3
Donnerstag, 11.06.2020
Titel
OSIsoft PI Web API 2019
Veröffentlicht
11. Juni 2020 16:05
Text
This advisory contains mitigations for a Cross-site Scripting vulnerability in OSIsoft PI Web API interface software.
Titel
Rockwell Automation FactoryTalk Linx Software
Veröffentlicht
11. Juni 2020 16:00
Text
This advisory contains mitigations for Improper Input Validation, Path Traversal, and Unrestricted Upload of File with Dangerous Type vulnerabilities in Rockwell Automation FactoryTalk Linx Software.
Dienstag, 09.06.2020
Titel
Mitsubishi Electric MELSEC iQ-R series
Veröffentlicht
9. Juni 2020 16:40
Text
This advisory contains mitigations for a resource exhaustion vulnerability in Mitsubishi Electric's MELSEC iQ-R series programmable logic controllers.
Titel
Siemens LOGO!
Veröffentlicht
9. Juni 2020 16:35
Text
This advisory contains mitigations for a Missing Authentication for Critical Function vulnerability in Siemens' LOGO! logic modules.
Titel
Siemens SIMATIC, SINAMICS, SINEC, SINEMA, SINUMERIK
Veröffentlicht
9. Juni 2020 16:30
Text
This advisory contains mitigations for an Unquoted Search Path or Element vulnerability in Siemens' SIMATIC, SINAMICS, SINEC, SINEMA, and SINUMERIK products.
Titel
Siemens SIMATIC, SINAMICS
Veröffentlicht
9. Juni 2020 16:25
Text
This advisory contains mitigations for Uncontrolled Search Path Element, Heap-based Buffer Overflow vulnerabilities in Siemens' SIMATIC and SINAMICS products.
Titel
Siemens SINUMERIK
Veröffentlicht
9. Juni 2020 16:20
Text
This advisory contains mitigations for several vulnerabilities in Siemens' SINUMERIK control system products.
Titel
OSIsoft PI System (Update A)
Veröffentlicht
9. Juni 2020 16:15
Text
This updated advisory is a follow-up to the original advisory titled ICSA-20-133-02 OSIsoft PI System that was published May 12, 2020, to the ICS webpage on us-cert.gov. This advisory contains mitigations for a several vulnerabilities in the OSIsoft PI System, a real-time data historian application.
Titel
Siemens Industrial Products (Update G)
Veröffentlicht
9. Juni 2020 16:10
Text
This updated advisory is a follow-up to the updated advisory titled ICSA-19-253-03 Siemens Industrial Products (Update F) that was published April 14, 2020, on the ICS webpage on us-cert.gov. This updated advisory includes mitigations for integer overflow or wraparound and uncontrolled resource consumption vulnerabilities reported in Siemens’ industrial products.
Titel
Siemens SIMATIC, SIMOCODE, SINAMICS, SITOP, and TIM (Update H)
Veröffentlicht
9. Juni 2020 16:05
Text
This updated advisory is a follow-up to the updated advisory titled ICSA-19-099-06 Siemens SIMATIC, SIMOCODE, SINAMICS, SITOP, and TIM (Update G) that was published March 10, 2020, to the ICS webpage on us-cert.gov. This advisory contains mitigations for an out-of-bounds read vulnerability in the Siemens SIMATIC, SIMOCODE, SINAMICS, SITOP, and ...
Titel
Philips PageWriter TC10, TC20, TC30, TC50, and TC70 Cardiographs (Update A)
Veröffentlicht
9. Juni 2020 16:00
Text
This updated advisory is a follow-up to the original advisory titled ICSMA-18-228-01 Philips PageWriter TC10, TC20, TC30, TC50, and TC70 Cardiographs that was published August 16, 2018, on the ICS webpage on us-cert.gov. This medical device advisory includes mitigation recommendations for improper input validation and use of hard-coded credentials vulnerabilities ...
Titel
SSA-352504 (Last Update: 2020-06-09): Urgent/11 TCP/IP Stack Vulnerabilities in Siemens Power Meters
Veröffentlicht
9. Juni 2020 02:00
Text
Siemens low & high voltage power meters are affected by multiple security vulnerabilities due to the underlying Wind River VxWorks network stack. This stack is affected by eleven vulnerabilities known as the "URGENT/11". The vulnerability could allow an attacker to execute a variety of exploits for the purpose of Denial-of-Service ...
Titel
SSA-817401 (Last Update: 2020-06-09): Missing Authentication Vulnerability in SIEMENS LOGO!
Veröffentlicht
9. Juni 2020 02:00
Text
A missing authentication vulnerability has been identified in SIEMENS LOGO!8 BM devices. The vulnerability could lead to an attacker reading and modifying the device configuration and obtain project files from the devices if the attacker has access to port 135/tcp.
Titel
SSA-689942 (Last Update: 2020-06-09): Denial-of-Service and DLL Hijacking Vulnerabilities in Multiple SIMATIC Software Products
Veröffentlicht
9. Juni 2020 02:00
Text
Multiple SIMATIC Software products are affected by two vulnerabilities that could allow an attacker to manipulate project files that may lead to Remote Code Execution or Denial-of-Service attacks. Siemens has released updates to some of the affected products and recommends that customers update to the latest version. Siemens is preparing ...
Titel
SSA-312271 (Last Update: 2020-06-09): Unquoted Search Path Vulnerabilities in Windows-based Industrial Software Applications
Veröffentlicht
9. Juni 2020 02:00
Text
The latest update for affected products fix local privilege escalation vulnerabilities that could allow authorized local users with administrative privileges to execute custom code with SYSTEM level privileges. Siemens has released updates for some of the affected products, and is working on further updates. For the remaining affected products, Siemens ...
Titel
SSA-462066 (Last Update: 2020-06-09): Vulnerability known as TCP SACK PANIC in Industrial Products
Veröffentlicht
9. Juni 2020 02:00
Text
Multiple industrial products are affected by a vulnerability in the kernel known as TCP SACK PANIC. The vulnerability could allow a remote attacker to cause a denial of service condition. Siemens has released updates for several affected products, and recommends that customers update to the latest version. Siemens is preparing ...
Titel
SSA-480230 (Last Update: 2020-06-09): Denial-of-Service in Webserver of Industrial Products
Veröffentlicht
9. Juni 2020 02:00
Text
A vulnerability in the affected devices could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends ...
Titel
SSA-927095 (Last Update: 2020-06-09): UltraVNC Vulnerabilities in SINUMERIK Products
Veröffentlicht
9. Juni 2020 02:00
Text
UltraVNC (V1.2.2.3 and below) vulnerabilities in the affected products could allow remote code execution, information disclosure and Denial-of-Service attacks under certain conditions. Siemens has released updates for the affected products and recommends that customers update to the latest versions.
Donnerstag, 04.06.2020
Titel
Medtronic Conexus Radio Frequency Telemetry Protocol (Update B)
Veröffentlicht
4. Juni 2020 16:00
Text
This updated advisory is a follow-up to the advisory update titled ICSMA-19-080-01 Medtronic Conexus Radio Frequency Telemetry Protocol (Update A) that was published January 30, 2020, on the ICS webpage on us-cert.gov. This medical advisory includes mitigations for improper access control and cleartext transmission of sensitive information vulnerabilities reported in ...
Dienstag, 02.06.2020
Titel
ABB System 800xA
Veröffentlicht
2. Juni 2020 16:30
Text
This advisory contains mitigations for Incorrect Default Permissions vulnerabilities in ABB's 800xA distributed control system.
Titel
ABB System 800xA Base
Veröffentlicht
2. Juni 2020 16:25
Text
This advisory contains mitigations for an Incorrect Permission Assignment for Critical Resource vulnerability in ABB's System 800xA Base distributed control system.
Titel
ABB Multiple System 800xA Products
Veröffentlicht
2. Juni 2020 16:20
Text
This advisory contains mitigations for Incorrect Default Permissions vulnerabilities in ABB's System 800xA distributed control system products.
Titel
ABB Central Licensing System
Veröffentlicht
2. Juni 2020 16:15
Text
This advisory contains mitigations for Information Exposure; Improper Restriction of XML External Entity Reference; Uncontrolled Resource Consumption; Permissions, Privilege, and Access Controls; Improper Access Control vulnerabilities in ABB's Central Licensing System (CLS) products.
Titel
GE Grid Solutions Reason RT Clocks
Veröffentlicht
2. Juni 2020 16:10
Text
This advisory contains mitigations for a Missing Authentication for Critical Function vulnerability in GE's Grid Solutions Reason RT Clocks.
Titel
SWARCO CPU LS4000
Veröffentlicht
2. Juni 2020 16:05
Text
This advisory contains mitigations for an Improper Access Control vulnerability in SWARCO TRAFFIC SYSTEMS' CPU LS4000 traffic light controllers.