SSA-270778 (Last Update: 2020-07-14): Denial-of-Service Vulnerability in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC Software
Veröffentlicht
14. Juli 2020 02:00
Text
A Denial-of-Service vulnerability was found in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC software when encrypted communication is enabled. The vulnerability could allow an attacker with network access to cause a Denial-of-Service condition under certain circumstances (versions prior to SIMATIC WinCC V7.3 or SIMATIC PCS 7 V8.1 are ...
Titel
SSA-293562 (Last Update: 2020-07-14): Vulnerabilities in Industrial Products
Veröffentlicht
14. Juli 2020 02:00
Text
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. The precondition for this scenario is a direct layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released updates ...
Titel
SSA-305120 (Last Update: 2020-07-14): Vulnerabilities in SICAM MMU, SICAM T and SICAM SGU
Veröffentlicht
14. Juli 2020 02:00
Text
SICAM MMU, SICAM T and the discontinued SICAM SGU devices are affected by multiple security vulnerabilities which could allow an attacker to perform a variety of attacks. This may include unauthenticated firmware installation, remote code execution and leakage of confidential data like passwords. Siemens has released updates to introduce authentication ...
Titel
SSA-312271 (Last Update: 2020-07-14): Unquoted Search Path Vulnerabilities in Windows-based Industrial Software Applications
Veröffentlicht
14. Juli 2020 02:00
Text
The latest update for affected products fix local privilege escalation vulnerabilities that could allow authorized local users with administrative privileges to execute custom code with SYSTEM level privileges. Siemens has released updates for some of the affected products, and is working on further updates. For the remaining affected products, Siemens ...
Titel
SSA-346262 (Last Update: 2020-07-14): Denial-of-Service in Industrial Products
Veröffentlicht
14. Juli 2020 02:00
Text
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates ...
Titel
SSA-364335 (Last Update: 2020-07-14): Clear Text Transmission Vulnerability on SIMATIC HMI Panels
Veröffentlicht
14. Juli 2020 02:00
Text
A clear text transmission vulnerability in SIMATIC HMI panels could allow an attacker to access sensitive information under certain circumstances. Siemens recommends specific countermeasures to mitigate this vulnerability.
Titel
SSA-398519 (Last Update: 2020-07-14): Vulnerabilities in Intel CPUs (November 2019)
Veröffentlicht
14. Juli 2020 02:00
Text
Intel has published information on vulnerabilities in Intel products in November 2019. In this advisory Siemens only explicitly mentions the vulnerabilities from the “Intel® CPU Security Advisory” and one vulnerability from “Intel® CSME, Intel® SPS, Intel® TXE, Intel® AMT, Intel® PTT and Intel® DAL Advisory” and lists the Siemens IPC ...
Titel
SSA-473245 (Last Update: 2020-07-14): Denial-of-Service Vulnerability in Profinet Devices
Veröffentlicht
14. Juli 2020 02:00
Text
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of specially crafted UDP packets are sent to the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates ...
Titel
SSA-573753 (Last Update: 2020-07-14): Remote Code Execution in Siemens LOGO! Web Server
Veröffentlicht
14. Juli 2020 02:00
Text
The latest update for LOGO! 8 BM devices fixes a vulnerability that could allow remote code execution in the web server functionality. Siemens provides a firmware update for the latest versions of LOGO! BM.
Titel
SSA-589181 (Last Update: 2020-07-14): Denial-Of-Service in SIMATIC S7-200 SMART CPU Family Devices
Veröffentlicht
14. Juli 2020 02:00
Text
The latest update for SIMATIC S7-200 SMART fixes a vulnerability that could allow an attacker to cause a permanent Denial-of-Service of an affected device by sending a large number of crafted packets. Siemens has released an update for the SIMATIC S7-200 SMART CPU family and recommends that customers update to ...
Titel
SSA-604937 (Last Update: 2020-07-14): Multiple Web Server Vulnerabilities in Opcenter Execution Core
Veröffentlicht
14. Juli 2020 02:00
Text
The latest update of Opcenter Execution Core fixes multiple vulnerabilities where the most severe could allow an attacker to perform a cross-site scripting (XSS) attack under certain conditions. Siemens has released an update for the Opcenter Execution Core and recommends that customers update to the latest version. Siemens recommends specific ...
Titel
SSA-631949 (Last Update: 2020-07-14): Ripple20 and Intel SPS Vulnerabilities in SPPA-T3000 Solutions
Veröffentlicht
14. Juli 2020 02:00
Text
SPPA-T3000 solutions are affected by vulnerabilities that were recently dislosed by JSOF research lab (“Ripple20”) for the TCP/IP stack used in APC UPS systems, and by Intel for the Server Platform Services (SPS) used in SPPA-T3000 Application Server and Terminal Server hardware. The advisory provides information to what amount SPAA-T3000 ...
Titel
SSA-671286 (Last Update: 2020-07-14): Multiple Vulnerabilities in SCALANCE Products
Veröffentlicht
14. Juli 2020 02:00
Text
The latest updates for the below mentioned products contain fixes for multiple vulnerabilities. The most severe could allow authenticated local users with physical access to the device to execute arbitrary commands on the device under certain conditions. Siemens has released updates for the affected products and recommends that customers update ...
Titel
SSA-689942 (Last Update: 2020-07-14): Denial-of-Service and DLL Hijacking Vulnerabilities in Multiple SIMATIC Software Products
Veröffentlicht
14. Juli 2020 02:00
Text
Multiple SIMATIC Software products are affected by two vulnerabilities that could allow an attacker to manipulate project files that may lead to Remote Code Execution or Denial-of-Service attacks. Siemens has released updates to some of the affected products and recommends that customers update to the latest version. Siemens is preparing ...
Titel
SSA-841348 (Last Update: 2020-07-14): Multiple Vulnerabilities in the UMC Stack
Veröffentlicht
14. Juli 2020 02:00
Text
The latest update for the below listed products fixes two security vulnerabilities that could allow an attacker to cause a partial Denial-of-Service on the UMC component of the affected devices under certain circumstances, and one vulnerability that could allow an attacker to locally escalate privileges from a user with administrative ...
Titel
SSA-978220 (Last Update: 2020-07-14): Denial-of-Service Vulnerability over SNMP in Multiple Industrial Products
Veröffentlicht
14. Juli 2020 02:00
Text
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates ...
Titel
SSB-439005 (Last Update: 2020-07-14): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Veröffentlicht
14. Juli 2020 02:00
Text
Titel
SSA-686531 (Last Update: 2020-07-14): Hardware based manufacturing access on S7-1200 and S7-200 SMART
Veröffentlicht
14. Juli 2020 02:00
Text
There is an access mode used during manufacturing of SIMATIC S7-1200 and S7-200 SMART CPUs that allows additional diagnostic functionality. Using this functionality requires physical access to the CPU during boot process. If additional protection from unauthorized use is needed Siemens provides specific countermeasures via an update of the device ...
Titel
AA20-195A: Critical Vulnerability in SAP NetWeaver AS Java
Veröffentlicht
14. Juli 2020 01:07
Text
Original release date: July 13, 2020SummaryOn July 13, 2020 EST, SAP released a security update to address a critical vulnerability, CVE-2020-6287, affecting the SAP NetWeaver Application Server (AS) Java component LM Configuration Wizard. An unauthenticated attacker can exploit this vulnerability through the Hypertext Transfer Protocol (HTTP) to take control of ...
Donnerstag, 09.07.2020
Titel
Phoenix Contact Automation Worx Software Suite
Veröffentlicht
9. Juli 2020 16:10
Text
This advisory contains mitigations for Stack-Based Buffer overflow and Out-of-Bounds Read vulnerabilities in Phoenix Contact Automation Worx Software Suite.
Titel
Rockwell Automation Logix Designer Studio 5000
Veröffentlicht
9. Juli 2020 16:05
Text
This advisory contains mitigations for Stack-Based Buffer Overflow and Out-of-Bounds Read vulnerabilities in Rockwell Automation Studio 5000 Logix Designer.
Mittwoch, 08.07.2020
Titel
Grundfos CIM 500
Veröffentlicht
8. Juli 2020 04:15
Text
This advisory contains mitigations for unprotected storage of credentials and missing authentication for critical function vulnerabilities in Grundfos CIM 500 products.
Dienstag, 07.07.2020
Titel
Mitsubishi Electric GOT2000 Series
Veröffentlicht
7. Juli 2020 16:10
Text
This advisory contains mitigations for Improper Restriction of Operations within the Bounds of a Memory Buffer, Session Fixation, NULL Pointer Dereference, Improper Access Control, Argument Injection, and Resource Management Errors vulnerabilities in Mitsubishi Electric GOT2000 Series products.
Donnerstag, 02.07.2020
Titel
OpenClinic GA
Veröffentlicht
2. Juli 2020 16:15
Text
This advisory contains mitigations for multiple vulnerabilities in OpenClinic GA, an open source integrated hospital information management system.
Titel
Nortek Linear eMerge 50P/5000P
Veröffentlicht
2. Juli 2020 16:10
Text
This advisory contains mitigations for Path Traversal, Command Injection, Unrestricted Upload of File with Dangerous Type, Cross-site Request Forgery, and Improper Authentication vulnerabilities in Nortek Linear eMerge 50P-5000P products.
  • 1
  • 2 (current)
  • 3

Letzte Updates

BOSCH PSIRT
20.03.2024
CODESYS
28.06.2023
SIEMENS CERT
26.03.2024
US CERT
26.02.2024
US CERT (ICS)
26.03.2024

Nach Quelle

Archiv

2024
2023
2022
2021
2020
2019
2018
2017

Feeds