April 2019
Title
SSA-436177 (Last Update: 2019-04-09): Multiple Vulnerabilities in SINEMA Remote Connect
Published
April 9, 2019, 2 a.m.
Summary
The latest updates for SINEMA Remote Connect Client and Server fix multiple vulnerabilities. One of these vulnerabilities could allow an attacker to circumvent the authorization of the system for certain functionalities and to execute privileged functions. Siemens has released firmware updates for SINEMA Remote Connect Client and Server.
Title
SSA-179516 (Last Update: 2019-04-09): OpenSSL Vulnerability in Industrial Products
Published
April 9, 2019, 2 a.m.
Summary
A vulnerability in OpenSSL affects several Siemens industrial products. Siemens has released updates for some affected products and is working on updates for others.
Title
SSA-141614 (Last Update: 2019-04-09): Denial-of-Service in SIMOCODE pro V EIP
Published
April 9, 2019, 2 a.m.
Summary
SIMOCODE pro V EIP is affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released an update for SIMOCODE pro V EIP and recommends that customers update to the new version.
Title
SSA-480230 (Last Update: 2019-04-09): Denial-of-Service in Webserver of Industrial Products
Published
April 9, 2019, 2 a.m.
Summary
A vulnerability in the affected devices could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends ...
Title
SSA-844562 (Last Update: 2019-04-09): Multiple Vulnerabilities in Licensing Software for WinCC OA
Published
April 9, 2019, 2 a.m.
Summary
Multiple vulnerabilities have been identified in the WibuKey Digital Rights Management (DRM) solution, which affect WinCC OA. Siemens recommends users to apply the updates to WibuKey Digital Rights Management (DRM) provided by WIBU SYSTEMS AG.
Title
Omron CX-Programmer
Published
April 4, 2019, 4:15 p.m.
Summary
This advisory includes mitigations for a use after free vulnerability reported in Omron's CX-Programmer PLC software.
Title
Rockwell Automation Stratix 5400/5410 and ArmorStratix 5700
Published
April 4, 2019, 4:10 p.m.
Summary
This advisory includes mitigations for an uncontrolled resource consumption vulnerability reported in Rockwell Automation's Stratix and ArmorStratix Ethernet switches.
Title
Rockwell Automation Stratix 5400/5410/5700 and ArmorStratix 5700
Published
April 4, 2019, 4:10 p.m.
Summary
This advisory includes mitigations for an uncontrolled resource consumption vulnerability reported in Rockwell Automation's Stratix and ArmorStratix Ethernet switches.
Title
Rockwell Automation Stratix 5400/5410/5700/8000/8300 and ArmorStratix 5700
Published
April 4, 2019, 4:05 p.m.
Summary
This advisory includes mitigations for resource management errors and improper input validation vulnerabilities reported in Rockwell Automation's Stratix 5400/5410/5700/8000/8300 and ArmorStratix 5700 switches.
Title
Rockwell Automation Stratix 5950
Published
April 4, 2019, 4 p.m.
Summary
This advisory includes mitigations for an improper input validation vulnerability reported in Rockwell Automation's Stratix 5950 security appliance products.
March 2019
Title
Rockwell Automation PowerFlex 525 AC Drives
Published
March 28, 2019, 3 p.m.
Summary
This advisory includes mitigations for a resource exhaustion vulnerability reported in Rockwell Automation's PowerFlex 525 AC drive.
Title
Siemens SCALANCE X
Published
March 26, 2019, 3:15 p.m.
Summary
This advisory includes mitigations for an expected behavior violation vulnerability reported in the Siemens SCALANCE X products.
Title
PHOENIX CONTACT RAD-80211-XD
Published
March 26, 2019, 3:10 p.m.
Summary
This advisory includes mitigations for a command injection vulnerability reported in Phoenix Contact's RAD-80211-XD WLAN wireless transceiver.
Title
ENTTEC Lighting Controllers
Published
March 26, 2019, 3 p.m.
Summary
This advisory includes mitigations for a missing authentication for critical function vulnerability reported in ENTTEC’s lighting controllers.
Title
Medtronic Conexus Radio Frequency Telemetry Protocol
Published
March 21, 2019, 3 p.m.
Summary
This medical advisory includes mitigations for improper access control and cleartext transmission of sensitive information vulnerabilities reported in Medtronic's proprietary Conexus telemetry system.
Title
Columbia Weather Systems MicroServer
Published
March 19, 2019, 3 p.m.
Summary
This advisory includes mitigations for cross-site scripting, path traversal, improper authentication, improper input validation, and code injection vulnerabilities in Columbia Weather Systems MicroServer weather monitoring system.
Title
LCDS LAquis SCADA ELS Files
Published
March 14, 2019, 3:10 p.m.
Summary
This advisory includes mitigations for an out-of-bounds write vulnerability in LCDS's LAquis SCADA industrial automation software.
Title
Gemalto Sentinel UltraPro
Published
March 14, 2019, 3:05 p.m.
Summary
This advisory includes mitigations for an uncontrolled search path element in Gemalto's Sentinel UltraPro encryption keys.
Title
PEPPERL+FUCHS WirelessHART-Gateways
Published
March 14, 2019, 3 p.m.
Summary
This advisory includes mitigations for a path traversal vulnerability in PEPPERL+FUCHS WirelessHART-Gateways network products.
Title
SSA-254686 (Last Update: 2019-03-12): Foreshadow / L1 Terminal Fault Vulnerabilities in Industrial Products
Published
March 12, 2019, 1 a.m.
Summary
Security researchers published information on vulnerabilities known as Foreshadow and L1 Terminal Fault (L1TF). These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerabilities.
Title
SSA-584286 (Last Update: 2019-03-12): Denial-of-Service Vulnerability in SIMATIC S7-1200 CPU and SIMATIC S7-1500 CPU
Published
March 12, 2019, 1 a.m.
Summary
A vulnerability was identified in SIMATIC S7-1200 and S7-1500 CPUs that could allow an attacker to cause a denial-of-service condition preventing HMI or engineering access to the PLC over port 102/tcp. Siemens has released an update for the S7-1500 product and recommends that customers update to the new version. Siemens ...
Title
SSA-170881 (Last Update: 2019-03-12): Vulnerabilities in SINUMERIK Controllers
Published
March 12, 2019, 1 a.m.
Summary
The latest updates for SINUMERIK controllers fix multiple security vulnerabilities that could allow an attacker to cause Denial-of-Service conditions, escalate privileges, or to execute code from remote. Siemens has released updates for several affected products, is working on updates for the remaining affected products and recommends specific countermeasures until fixes ...
Title
SSA-168644 (Last Update: 2019-03-12): Spectre and Meltdown Vulnerabilities in Industrial Products
Published
March 12, 2019, 1 a.m.
Summary
Security researchers published information on vulnerabilities known as Spectre and Meltdown. These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Industrial Products include affected processors and are affected by the vulnerabilities.
Title
SSA-203306 (Last Update: 2019-03-12): Password Vulnerabilities in SIPROTEC 4 and SIPROTEC Compact Relay Families
Published
March 12, 2019, 1 a.m.
Summary
SIPROTEC 4 and SIPROTEC Compact devices could allow access authorization passwords to be reconstructed or overwritten via engineering mechanisms that involve DIGSI 4 and EN100 Ethernet communication modules. Siemens has released updates for several affected products, and recommends specific countermeasures for the remaining products.
Title
SSA-348629 (Last Update: 2019-03-12): Denial-of-Service Vulnerability in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC Software
Published
March 12, 2019, 1 a.m.
Summary
A Denial-of-Service vulnerability has been identified in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC-Software. Siemens has released updates for several affected products and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific countermeasures until patches are available.