August 2019
Title
SSA-232418 (Last Update: 2019-08-13): Vulnerabilities in SIMATIC S7-1200 and SIMATIC S7-1500 CPU families
Published
Aug. 13, 2019, 2 a.m.
Summary
Two vulnerabilities have been identified in the SIMATIC S7-1200 and the SIMATIC S7-1500 CPU families. One vulnerability could allow an attacker with network access to affected devices to modify the user program stored on these devices such that the source code differs from the actual running code. The other vulnerability ...
Title
SSA-747162 (Last Update: 2019-08-13): Cross-Site Scripting Vulnerability in Spectrum Power™
Published
Aug. 13, 2019, 2 a.m.
Summary
A Cross-Site Scripting (XSS) vulnerability was found in the WebSDK component of Spectrum Power™ 3, 4, 5 and 7. A software update is available to address the issue and Siemens recommends installing the patch.
Title
SSA-671286 (Last Update: 2019-08-13): Multiple Vulnerabilities in SCALANCE Products
Published
Aug. 13, 2019, 2 a.m.
Summary
The latest update for SCALANCE SC-600 fixes multiple vulnerabilities. The most severe could allow authenticated local users with physical access to the device to execute arbitrary commands on the device under certain conditions. Siemens has released updates for SCALANCE SC-600 devices.
Title
SSB-439005 (Last Update: 2019-08-13): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Published
Aug. 13, 2019, 2 a.m.
Summary
Title
SSA-632562 (Last Update: 2019-08-02): Vulnerabilities in SIPROTEC 5 Ethernet plug-in communication modules and devices
Published
Aug. 2, 2019, 2 a.m.
Summary
The SIPROTEC 5 Ethernet plug-in communication modules and devices are affected by multiple security vulnerabilities. These vulnerabilities could allow an attacker to leverage various attacks, e.g. to execute arbitrary code over the network. Eleven of these vulnerabilities affect the underlying Wind River VxWorks network stack and were recently patched by ...
Title
Fuji Electric FRENIC Loader
Published
Aug. 1, 2019, 7:50 p.m.
Summary
This advisory includes mitigations for an out-of-bounds read vulnerability reported in the Fuji Electric FRENIC Loader AC drive.
Title
3S-Smart Software Solutions GmbH CODESYS V3
Published
Aug. 1, 2019, 7:43 p.m.
Summary
This advisory includes mitigations for two vulnerabilities, unverified ownership and uncontrolled memory allocation, reported in the 3S-Smart Software Solutions GmbH CODESYS V3 products.
Title
Rockwell Automation Arena Simulation Software
Published
Aug. 1, 2019, 7:11 p.m.
Summary
This advisory provides information about, and mitigation recommendations for, two vulnerabilities reported in the Rockwell Automation Arena Automation software.
Title
LCDS LAquis SCADA LQS File Parsing
Published
Aug. 1, 2019, 6:58 p.m.
Summary
This advisory includes mitigations for out-of-bounds read and type confusion vulnerabilities reported in the LCDS LAquis SCADA software.
July 2019
Title
Wind River VxWorks (Update A)
Published
July 30, 2019, 4:05 p.m.
Summary
This updated advisory is a follow-up to the original advisory titled ICSA-19-211-01 Wind River VxWorks that was published July 30, 2019, on the ICS webpage on us-cert.gov.This advisory includes mitigations for stack-based buffer overflow, heap-based buffer overflow, integer underflow, improper restriction of operations within the bounds of a memory buffer, ...
Title
Wind River VxWorks
Published
July 30, 2019, 4:05 p.m.
Summary
This advisory includes mitigations for stack-based buffer overflow, heap-based buffer overflow, integer underflow, improper restriction of operations within the bounds of a memory buffer, race condition, argument condition or modification, null pointer dereference, and argument injection or modification vulnerabilities reported in Wind River’s VxWorks.
Title
Prima Systems FlexAir
Published
July 30, 2019, 4 p.m.
Summary
This advisory includes mitigations for OS command Injection, unrestricted upload of file with dangerous type, sross-site request forgery, small space of random values, cross-site scripting, exposure of backup file to unauthorized control sphere, improper authentication, and use of hard-coded credentials vulnerabilities reported in Prima Systems' FlexAir access control platform.
Title
CAN Bus Network Implementation in Avionics
Published
July 30, 2019, 3 p.m.
Summary
CISA is aware of a public report of insecure implementation of CAN bus networks affecting aircraft. According to this report, the CAN bus networks are exploitable when an attacker has unsupervised physical access to the aircraft. CISA is issuing this alert to provide early notice of the report.
Title
Mitsubishi Electric FR Configurator2
Published
July 23, 2019, 4:05 p.m.
Summary
This advisory contains mitigation details for improper restriction of XML external entity reference and uncontrolled resource consumption vulnerabilities in Mitsubishi Electric's FR Configurator variable frequency drives.
Title
NREL EnergyPlus
Published
July 23, 2019, 4 p.m.
Summary
This advisory includes mitigations for a stack-based buffer overflow vulnerability in the NREL EnergyPlus software.
Title
Johnson Controls exacqVision Server
Published
July 16, 2019, 10:37 p.m.
Summary
This advisory includes mitigations for an unquoted search path or element vulnerability reported in the Johnson Controls exacqVision Server.
Title
Philips Holter 2010 Plus
Published
July 11, 2019, 4:35 p.m.
Summary
This advisory provides information about, and mitigations for, a vulnerability reported in the Philips Holter 2010 Plus.
Title
Delta Industrial Automation CNCSoft ScreenEditor
Published
July 11, 2019, 4:30 p.m.
Summary
This advisory includes mitigations for heap-based buffer overflow and out-of-bounds read vulnerabilities reported in the Delta Electronics CNCSoft ScreenEditor.
Title
Siemens SIMATIC WinCC and PCS7
Published
July 11, 2019, 4:25 p.m.
Summary
This advisory includes mitigations for an unrestricted upload of file with dangerous type vulnerability reported in the Siemens SIMATIC WinCC and SIMATIC PCS7 industrial products.
Title
Siemens TIA Administrator (TIA Portal)
Published
July 11, 2019, 4:20 p.m.
Summary
This advisory provides information about, and mitigations for, a vulnerability in the Siemens TIA Administrator (TIA Portal) application.
Title
Siemens SIMATIC RF6XXR
Published
July 11, 2019, 4:15 p.m.
Summary
This advisory provides information about, and mitigations for, several vulnerabilities in the Siemens SIMATIC RF6XXR series devices.
Title
AVEVA Vijeo Citect and Citect SCADA Floating License Manager
Published
July 11, 2019, 4:10 p.m.
Summary
This advisory provides information about, and mitigations for, several vulnerabilities reported in the AVEVA Vijeo Citect and Citect SCADA Floating License Manager applications.
Title
Schneider Electric Interactive Graphical SCADA System
Published
July 11, 2019, 4:05 p.m.
Summary
This advisory includes mitigations for an out-of-bounds write vulnerability in the Schneider Electric Interactive Graphical SCADA System software.
Title
SSA-616472 (Last Update: 2019-07-09): ZombieLoad and Microarchitectural Data Sampling Vulnerabilities in Industrial Products
Published
July 9, 2019, 2 a.m.
Summary
Security researchers published information on vulnerabilities known as ZombieLoad and Microarchitectural Data Sampling (MDS). These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerabilities.
Title
SSA-121293 (Last Update: 2019-07-09): Code Upload Vulnerability in SIMATIC WinCC and SIMATIC PCS7
Published
July 9, 2019, 2 a.m.
Summary
The latest update for SIMATIC WinCC fixes a vulnerability in the SIMATIC WinCC DataMonitor web application of the affected products that allows to upload arbitrary ASPX code. An attacker has to be authenticated with a valid user account. The vulnerability is only relevant for scenarios where access via the web ...

Last Updates

BOSCH PSIRT
19.07.2024
SIEMENS CERT
22.07.2024
US CERT
24.07.2024
US CERT (ICS)
25.07.2024

By Source

Archive

2024
2023
2022
2021
2020
2019
2018
2017