October 2018
Title
Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server
Published
Oct. 9, 2018, 4:05 p.m.
Summary
This advisory includes information on the predictable from observable state, hidden functionality, and missing encryption of sensitive data vulnerabilities in the Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server.
Title
Fuji Electric Energy Savings Estimator
Published
Oct. 9, 2018, 4 p.m.
Summary
This advisory includes mitigations for an uncontrolled search path element (DLL Hijacking) vulnerability in the Fuji Electric Energy Savings Estimator software.
Title
SSA-493830 (Last Update: 2018-10-09): Privilege Escalation in ROX II
Published
Oct. 9, 2018, 2 a.m.
Summary
The latest update for ROX II fixes two vulnerabilities. One vulnerability could allow an attacker with a low-privileged user account to execute arbitrary commands. The other vulnerability could allow an attacker with a low-privileged user account to escalate his privileges. Siemens recommends to update to the new version as soon ...
Title
SSA-597741 (Last Update: 2018-10-09): Vulnerability in iOS App SIMATIC WinCC OA Operator
Published
Oct. 9, 2018, 2 a.m.
Summary
The SIMATIC WinCC OA Operator iOS app is affected by a security vulnerability which could allow an attacker to read unencrypted data from the application’s directory. Precondition for this scenario is that an attacker has physical access to the mobile device.
Title
SSA-546832 (Last Update: 2018-10-09): Vulnerabilities in Medium Voltage SINAMICS Products
Published
Oct. 9, 2018, 2 a.m.
Summary
The latest updates for medium voltage SINAMICS products fix two security vulnerabilities that could allow an attacker to cause a Denial-of-Service condition either via specially crafted PROFINET DCP broadcast packets or by sending specially crafted packets to port 161/udp (SNMP). Precondition for the PROFINET DCP scenario is a direct Layer ...
Title
SSA-979106 (Last Update: 2018-10-09): Vulnerabilities in SIMATIC STEP 7 (TIA Portal) and SIMATIC WinCC (TIA Portal)
Published
Oct. 9, 2018, 2 a.m.
Summary
The latest updates for SIMATIC STEP 7 (TIA Portal) and SIMATIC WinCC (TIA Portal) fix two vulnerabilities. These two vulnerabilities could either allow an attacker with local file write access to manipulate files and cause a Denial-of-service-condition, or execute code both on the manipulated installation and on devices that are ...
Title
SSA-268644 (Last Update: 2018-10-09): Spectre-NG (Variants 3a and 4) Vulnerabilities in Industrial Products
Published
Oct. 9, 2018, 2 a.m.
Summary
Security researchers published information on vulnerabilities known as Spectre-NG (Variants 3a and 4). These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Industrial Products include affected processors and are affected by the vulnerabilities.
Title
SSA-464260 (Last Update: 2018-10-09): TLS ROBOT vulnerability in SCALANCE W1750D
Published
Oct. 9, 2018, 2 a.m.
Summary
The latest update for SCALANCE W1750D addresses a vulnerability known as ROBOT Attack. The vulnerability could allow an attacker to decrypt TLS traffic. Siemens provides a firmware update and recommends users to update to the new version.
Title
SSA-346262 (Last Update: 2018-10-09): Denial-of-Service in Industrial Products
Published
Oct. 9, 2018, 2 a.m.
Summary
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates ...
Title
SSA-347726 (Last Update: 2018-10-09): Denial-of-Service Vulnerability in SIMATIC S7-1500, SIMATIC S7-1500 Software Controller and SIMATIC ET 200SP Open Controller
Published
Oct. 9, 2018, 2 a.m.
Summary
Versions of SIMATIC S7-1500, SIMATIC S7-1500 Software Controller and SIMATIC ET 200 SP Open Controller are affected by a denial-of-service vulnerability. An attacker with network access to the PLC can cause a Denial-of-Service condition on the network stack.
Title
SSA-507847 (Last Update: 2018-10-09): Cross-Site Request Forgery Vulnerability in SIMATIC S7-1200 CPU Family Version 4
Published
Oct. 9, 2018, 2 a.m.
Summary
The latest firmware update for S7-1200 CPU family version 4 fixes a Cross-Site Request Forgery vulnerability. Siemens recommends to update affected devices as soon as possible.
Title
SSA-254686 (Last Update: 2018-10-09): Foreshadow / L1 Terminal Fault Vulnerabilities in Industrial Products
Published
Oct. 9, 2018, 2 a.m.
Summary
Security researchers published information on vulnerabilities known as Foreshadow and L1 Terminal Fault (L1TF). These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerabilities.
Title
SSA-179516 (Last Update: 2018-10-09): OpenSSL Vulnerability in Industrial Products
Published
Oct. 9, 2018, 2 a.m.
Summary
A vulnerability in OpenSSL affects several Siemens industrial products. Siemens has released updates for some affected products and is working on updates for others.
Title
SSA-348629 (Last Update: 2018-10-09): Denial-of-Service Vulnerability in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC Software
Published
Oct. 9, 2018, 2 a.m.
Summary
A Denial-of-Service vulnerability has been identified in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC-Software. Siemens has released updates for several affected products and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific countermeasures until patches are available.
Title
SSA-592007 (Last Update: 2018-10-09): Denial-of-Service Vulnerability in Industrial Products
Published
Oct. 9, 2018, 2 a.m.
Summary
Several industrial controllers are affected by a security vulnerability that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct OSI Layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released ...
Title
Siemens SCALANCE W1750D
Published
Oct. 8, 2018, 4:25 p.m.
Summary
This advisory includes mitigations for a cryptographic issues vulnerability in Siemens' SCALANCE W1750D direct access point hardware.
Title
Carestream Vue RIS
Published
Oct. 4, 2018, 4:10 p.m.
Summary
This advisory includes mitigations for an information exposure through an error message vulnerability in the Carestream Vue RIS, a web-based radiology information system.
Title
Change Healthcare PeerVue Web Server
Published
Oct. 4, 2018, 4:05 p.m.
Summary
This advisory includes mitigations for an information exposure through an error message vulnerability in the Change Healthcare PeerVue Web Server.
Title
WECON PI Studio
Published
Oct. 4, 2018, 4 p.m.
Summary
This advisory includes information on stack-based buffer overflow, out-of-bounds write, and out-of-bounds read vulnerabilities in WECON’s PI Studio HMI project programmer.
Title
Delta Electronics ISPSoft
Published
Oct. 2, 2018, 4:10 p.m.
Summary
This advisory includes mitigations for a stack-based buffer overflow vulnerability in the Delta Electronics ISPSoft software.
Title
GE Communicator
Published
Oct. 2, 2018, 4:05 p.m.
Summary
This advisory includes mitigations for a heap-based buffer overflow vulnerability in GE's Communicator, an application for programming and monitoring supported metering devices.
Title
Entes EMG 12
Published
Oct. 2, 2018, 4 p.m.
Summary
This advisory includes mitigations for improper authentication and information exposure through query strings in GET request vulnerabilities in the Entes EMG 12 Ethernet Modbus Gateway.
September 2018
Title
Emerson AMS Device Manager
Published
Sept. 27, 2018, 4:15 p.m.
Summary
This advisory includes mitigations for improper access control and improper privilege management vulnerabilities in the Emerson AMS Device Manager software.
Title
Fuji Electric Alpha5 Smart Loader
Published
Sept. 27, 2018, 4:10 p.m.
Summary
This advisory includes information on classic buffer overflow and heap-based buffer overflow vulnerabilities in Fuji Electric's Alpha5 Smart Loader servo drive.
Title
Fuji Electric FRENIC Devices
Published
Sept. 27, 2018, 4:05 p.m.
Summary
This advisory includes information on buffer over-read, out-of-bounds read, and stack-based buffer overflow vulnerabilities in Fuji Electric's FRENIC HVAC drive devices.

Last Updates

BOSCH PSIRT
19.07.2024
SIEMENS CERT
22.07.2024
US CERT
24.07.2024
US CERT (ICS)
25.07.2024

By Source

Archive

2024
2023
2022
2021
2020
2019
2018
2017

Feeds