This advisory contains mitigation details for stack-based buffer overflow and permissions, privileges, and access controls vulnerabilities in the Siemens' SIMATIC, SIMOTION, and SINUMERIK Industrial PCs.
This advisory contains mitigation details for reliance on cookies without validation and integrity checking, improper handling of length parameter inconsistency, and NULL pointer dereference vulnerabilities in the Moxa OnCell G3100-HSPA Series IP gateway.
This advisory contains mitigation details for a stack-based buffer overflow vulnerability in the Delta Electronics Delta Industrial Automation DOPSoft human machine interface.
This updated advisory is a follow-up to the original advisory titled ICSA-18-058-01 Siemens SIMATIC Industrial PCs that was published February 27, 2018, on the NCCIC/ICS-CERT website. This updated advisory contains mitigation details for cryptographic issue vulnerabilities in the Siemens' SIMATIC Industrial PCs.
This advisory includes mitigation recommendations for a stack-based buffer overflow vulnerability in the Emerson ControlWave Micro Process Automation Controller.
This medical device advisory contains mitigation details for vulnerabilities in Medtronic’s 2090 CareLink Programmer and its accompanying software deployment network.
This medical device advisory contains mitigation details for vulnerabilities in the Philips’ IntelliSpace Portal (ISP), an advanced visualization and image analysis system.
Security researchers published information on vulnerabilities known as Spectre and Meltdown. These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Industrial Products include affected processors and are affected by the vulnerabilities.
Multiple SIMATIC WinCC Add-Ons released in 2015 and earlier include a vulnerable version of Gemalto Sentinel LDK RTE. Gemalto Sentinel LDK RTE is affected by a vulnerability that could allow remote code execution. Siemens recommends to update the affected software component Gemalto Sentinel LDK RTE.
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates ...
Select Ultrasound products from Siemens Healthineers are affected by the Microsoft Windows SMBv1 vulnerabilities. The exploitability of the vulnerabilities depends on the actual configuration and deployment environment of each product. Siemens Healthineers provides updates for the affected products, and recommends specific countermeasures until patches can be applied.
The RUGGEDCOM RCDP protocol is not properly configured after commissioning of RUGGEDCOM ROS based devices and some SCALANCE X switch models and could allow unauthenticated remote users to perform administrative operations. An attacker must be in the same adjacent network and the RCDP daemon must be enabled in order to ...
Intel has identified vulnerabilities in Intel Management Engine (ME), Intel Server Platform Services (SPS), and Intel Trusted Execution Engine (TXE). As several Siemens Industrial PCs use Intel technology, they are also affected. Siemens has released updates for the affected Industrial PCs.
Several SIMATIC IPCs include a version of Infineon's Trusted Platform Module (TPM) firmware that mishandles RSA key generation. This makes it easier for attackers to conduct cryptographic attacks against the key material. Siemens has released updates for the affected Industrial PCs.
Several industrial products are affected by a vulnerability that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct Layer 2 access to the affected products. Siemens has released updates for several affected products, is working ...
This advisory contains mitigation details for stack-based buffer overflow and improper restriction of operations within the bounds of a memory buffer vulnerabilities in GE’s D60 Line Distance Relay.
This advisory contains mitigation details for Improper certificate validation and plaintext storage of a password vulnerabilities in the Schneider Electric IGSS Mobile products.
This advisory contains mitigation details for an unrestricted upload of file with dangerous type vulnerability in Schneider Electric's StruxureOn Gateway software management platform.
This medical device advisory contains mitigation details for an uncontrolled search path element vulnerability in Vyaire Medical’s CareFusion Upgrade Utility application.