September 2022
Titel
SSA-459643 V1.0: Denial of Service Vulnerability in RUGGEDCOM ROS before V5.6.0
Veröffentlicht
13. September 2022 02:00
Text
RUGGEDCOM ROS-based devices are vulnerable to a denial of service attack (Slowloris). By sending partial HTTP requests nonstop, with none completed, the affected web servers will be waiting for the completion of each request, occupying all available HTTP connections. The web server recovers by itself once the attack ends. Siemens ...
Titel
SSA-637483 V1.0: Third-Party Component Vulnerabilities in SINEC INS before V1.0 SP2
Veröffentlicht
13. September 2022 02:00
Text
Multiple vulnerabilities affecting various third-party components of SINEC INS before V1.0 SP2 could allow an attacker to cause a denial of service condition, disclose sensitive data or violate the system integrity. Siemens has released an update for the SINEC INS and recommends to update to the latest version.
Titel
SSA-618620 V1.1 (Last Update: 2022-09-13): Vulnerabilities in Boot Loader (U-Boot) of RUGGEDCOM ROS Devices
Veröffentlicht
13. September 2022 02:00
Text
The boot loader within RUGGEDCOM ROS contains two vulnerabilities in the loading process of the operating system kernel. The more severe of these vulnerabilities could allow an attacker with local access to the device to execute arbitrary code on an affected device. Siemens recommends specific countermeasures to mitigate this issue.
Titel
SSA-179516 V1.7 (Last Update: 2022-09-13): OpenSSL Vulnerability in Industrial Products
Veröffentlicht
13. September 2022 02:00
Text
Several Siemens industrial products are affected by a vulnerability in OpenSSL, that could result in data being sent out unencrypted by the SSL/TLS record layer. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-712929 V1.3 (Last Update: 2022-09-13): Denial of Service Vulnerability in OpenSSL (CVE-2022-0778) Affecting Industrial Products
Veröffentlicht
13. September 2022 02:00
Text
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released updates for several affected products and recommends to update to the latest ...
Titel
SSA-589975 V1.0: Improper Access Control Vulnerability in CoreShield OWG Software
Veröffentlicht
13. September 2022 02:00
Text
The default installation of the Windows version of the CoreShield One-Way Gateway (OWG) software sets insecure file permissions that could allow a local attacker to escalate privileges to local administrator. Siemens Mobility has released an update for the CoreShield OWG software and recommends to update to the latest version.
Titel
SSA-710008 V1.1 (Last Update: 2022-09-13): Multiple Web Vulnerabilities in SCALANCE Products
Veröffentlicht
13. September 2022 02:00
Text
SCALANCE devices contain multiple vulnerabilities in MSPS based product lines that could allow authenticated remote attackers to execute custom code or create a XSS situation, as well as unauthenticated remote attackers to create a denial of service condition. Siemens has released updates for several affected products and recommends to update ...
Titel
SSB-439005 V4.7 (Last Update: 2022-09-13): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Veröffentlicht
13. September 2022 02:00
Text
August 2022
Titel
SSA-285795 V1.2 (Last Update: 2022-08-09): Denial of Service in OPC-UA in Industrial Products
Veröffentlicht
9. August 2022 02:00
Text
A vulnerability in the underlying third party component OPC UA ANSIC Stack (also called Legacy C-Stack) affects several industrial products. The vulnerability could cause a crash of the component that includes the vulnerable part of the stack. Siemens has released updates for several affected products and recommends to update to ...
Titel
SSA-243317 V1.1 (Last Update: 2022-08-09): File Parsing Vulnerability in Simcenter Femap and Parasolid
Veröffentlicht
9. August 2022 02:00
Text
Simcenter Femap and Parasolid are affected by an out of bounds read vulnerability that could be triggered when the application reads files in NEU format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution ...
Titel
SSA-244969 V1.7 (Last Update: 2022-08-09): OpenSSL Vulnerability in Industrial Products
Veröffentlicht
9. August 2022 02:00
Text
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1l and 1.0.2 < 1.0.2za that allows an attacker to cause a denial of service (DoS) or to disclose private memory content. Siemens has released updates for several affected products and recommends to update to ...
Titel
SSA-324955 V1.9 (Last Update: 2022-08-09): SAD DNS Attack in Linux Based Products
Veröffentlicht
9. August 2022 02:00
Text
A vulnerability made public under the name SAD DNS affects Domain Name System resolvers due to a vulnerability in the Linux kernel when handling ICMP packets. The Siemens products which are affected are listed below. For more information please see https://www.saddns.net/. Siemens has released updates for several affected products and ...
Titel
SSA-321292 V1.2 (Last Update: 2022-08-09): Denial of Service in the OPC Foundation Local Discovery Server (LDS) in Industrial Products
Veröffentlicht
9. August 2022 02:00
Text
A vulnerability has been identified in the OPC Foundation Local Discovery Server (LDS) [0] of several industrial products. The vulnerability could cause a denial of service condition on the service or the device. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens ...
Titel
SSA-431678 V1.3 (Last Update: 2022-08-09): Denial-of-Service Vulnerability in SIMATIC S7 CPU Families
Veröffentlicht
9. August 2022 02:00
Text
SIMATIC S7 CPU families are affected by a vulnerability that could allow remote attackers to perform a Denial-of-Service attack by sending a specially crafted HTTP request to the web server of an affected device. Siemens has released updates for several affected products, is working on updates for the remaining affected ...
Titel
SSA-429204 V1.1 (Last Update: 2022-08-09): Open Design Alliance Drawings SDK Vulnerabilities in JT2Go and Teamcenter Visualization
Veröffentlicht
9. August 2022 02:00
Text
JT2Go and Teamcenter Visualization are affected by multiple file parsing vulnerabilities in Drawings SDK from Open Design Alliance. If a user is tricked to open a malicious DWG file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens ...
Titel
SSA-309571 V1.5 (Last Update: 2022-08-09): IPU 2021.1 Vulnerabilities in Siemens Industrial Products using Intel CPUs (June 2021)
Veröffentlicht
9. August 2022 02:00
Text
Intel has published information on vulnerabilities in Intel products in June 2021. This advisory lists the related Siemens Industrial products affected by these vulnerabilities that can be patched by applying the corresponding BIOS update. In this advisory we summarize: “2021.1 IPU – Intel® CSME, SPS and LMS Advisory” Intel-SA-00459, “2021.1 ...
Titel
SSA-220589 V1.2 (Last Update: 2022-08-09): Hard Coded Default Credential Vulnerability in Teamcenter
Veröffentlicht
9. August 2022 02:00
Text
Siemens has released updates for Teamcenter that fixes a security vulnerability related to unsecure storage of user credentials. This vulnerability affects Java EE Server Manager HTML Adaptor. This service is not installed by default and currently also obsoleted. Siemens has released updates for the affected products and recommends to update ...
Titel
SSA-307392 V1.9 (Last Update: 2022-08-09): Denial of Service in OPC UA in Industrial Products
Veröffentlicht
9. August 2022 02:00
Text
A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a denial of service condition on the service or the device. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for ...
Titel
SSB-439005 V4.6 (Last Update: 2022-08-09): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Veröffentlicht
9. August 2022 02:00
Text
Titel
SSA-232418 V1.4 (Last Update: 2022-08-09): Vulnerabilities in SIMATIC S7-1200 and SIMATIC S7-1500 CPU Families
Veröffentlicht
9. August 2022 02:00
Text
Two vulnerabilities have been identified in the SIMATIC S7-1200/S7-1500 CPU families and related products. One vulnerability (CVE-2019-10943) could allow an attacker with network access to affected devices to modify the user program stored on these devices such that the source code differs from the actual running code. The other vulnerability ...
Titel
SSA-517377 V1.1 (Last Update: 2022-08-09): Multiple Vulnerabilities in the SRCS VPN Feature in SIMATIC CP Devices
Veröffentlicht
9. August 2022 02:00
Text
The below referenced devices contain multiple vulnerabilities that could be exploited when the SINEMA Remote Connect Server (SRCS) VPN feature is used. The feature is not activated by default. The most severe could allow an attacker to execute arbitrary code with elevated privileges under certain circumstances. Siemens has released an ...
Titel
SSA-539476 V1.3 (Last Update: 2022-08-09): Siemens SIMATIC NET CP, SINEMA and SCALANCE Products Affected by Vulnerabilities in Third-Party Component strongSwan
Veröffentlicht
9. August 2022 02:00
Text
Vulnerabilities in the third-party component strongSwan could allow an attacker to cause a denial of service (DoS) condition in affected devices by exploiting integer overflow bugs. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends countermeasures ...
Titel
SSA-492828 V1.2 (Last Update: 2022-08-09): Denial-of-Service Vulnerability in SIMATIC S7-300 CPUs and SINUMERIK Controller
Veröffentlicht
9. August 2022 02:00
Text
A vulnerability in S7-300 might allow an attacker to cause a Denial-of-Service condition on port 102 of the affected devices by sending specially crafted packets. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
Titel
SSA-557541 V1.1 (Last Update: 2022-08-09): Denial-of-Service Vulnerability in SIMATIC S7-400 CPUs
Veröffentlicht
9. August 2022 02:00
Text
SIMATIC S7-400 CPU devices contain an input validation vulnerability that could allow an attacker to create a Denial-of-Service condition. A restart is needed to restore normal operations. Siemens has released an update for SIMATIC S7-410 V10 CPU family and SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants for both) ...
Titel
SSA-580125 V1.1 (Last Update: 2022-08-09): Multiple Vulnerabilities in SIMATIC eaSie
Veröffentlicht
9. August 2022 02:00
Text
SIMATIC eaSie contains multiple vulnerabilities that could allow an attacker to send arbitrary messages to the underlying message passing framework of the affected system or crash the attached application. Siemens has released an update for the SIMATIC eaSie Core Package and recommends to update to the latest version.

Letzte Updates

BOSCH PSIRT
19.10.2022
CODESYS
03.11.2022
SIEMENS CERT
08.11.2022
US CERT
01.12.2022
US CERT (ICS)