Oktober 2023
Titel
SSA-295483 V1.0: User Enumeration Vulnerability in Mendix Forgot Password Module
Veröffentlicht
10. Oktober 2023 02:00
Text
The Mendix Forgot Password module contains a user enumeration vulnerability that could allow an attacker to retrieve valid users. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-285795 V1.4 (Last Update: 2023-10-10): Denial of Service in OPC-UA in Industrial Products
Veröffentlicht
10. Oktober 2023 02:00
Text
A vulnerability in the underlying third party component OPC UA ANSIC Stack (also called Legacy C-Stack) affects several industrial products. The vulnerability could cause a crash of the component that includes the vulnerable part of the stack. Siemens has released updates for the affected products and recommends to update to ...
Titel
SSA-784849 V1.0: Direct Memory Access Vulnerabilities in SIMATIC CP Devices
Veröffentlicht
10. Oktober 2023 02:00
Text
Several SIMATIC CP devices contain direct memory access vulnerabilities that could allow an attacker to execute code, access the PROFINET network without restrictions or perform denial of service attacks. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
Titel
SSA-843070 V1.0: Multiple Vulnerabilities in SCALANCE W1750D
Veröffentlicht
10. Oktober 2023 02:00
Text
The SCALANCE W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or exploit buffer overflow vulnerabilities which could lead to sensitive information disclosure, unauthenticated denial of service or unauthenticated remote code execution. Siemens has released updates for the affected products and recommends to update to the ...
Titel
SSA-516174 V1.1 (Last Update: 2023-10-10): Wi-Fi Encryption Bypass Vulnerabilities in SCALANCE W1750D
Veröffentlicht
10. Oktober 2023 02:00
Text
The SCALANCE W1750D device is affected by Wi-Fi encryption bypass vulnerabilities (“Framing Frames”) that could allow an attacker to disclose sensitive information or to steal the victims session. Siemens has released updates for the affected products and recommends to update to the latest versions.
September 2023
Titel
SSA-357182 V1.0: Local Privilege Escalation Vulnerability in Spectrum Power 7
Veröffentlicht
14. September 2023 02:00
Text
Spectrum Power 7 is affected by a vulnerability that could allow an authenticated local attacker to inject arbitrary code to the update script and escalate privileges. Siemens has released an update for Spectrum Power 7 and recommends to update to the latest version.
Titel
SSA-646240 V1.0: Sensitive Information Disclosure in SIMATIC PCS neo Administration Console
Veröffentlicht
14. September 2023 02:00
Text
The Administration Console of SIMATIC PCS neo leaks Windows admin credentials. An attacker with local Windows access to the Administration Console could get the credentials, and impersonate the admin user, thereby gaining admin access to other Windows systems. Siemens has released a security patch for the affected products and recommends ...
Titel
SSA-587547 V1.1 (Last Update: 2023-09-12): Unencrypted Storage of User Credentials in QMS Automotive
Veröffentlicht
12. September 2023 02:00
Text
QMS Automotive contains a vulnerability that stores user credentials in plantext within the user database. This could allow an attacker to read credentials from memory. Siemens has released an update for QMS Automotive and recommends to update to the latest version.
Titel
SSA-552874 V1.2 (Last Update: 2023-09-12): Denial of Service Vulnerability in SIPROTEC 5 Devices
Veröffentlicht
12. September 2023 02:00
Text
Devices of the SIPROTEC 5 family contain a vulnerability related to secure client-initiated renegotiation. This could allow an unauthenticated attacker to cause a denial of service condition for the duration of the attack. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens ...
Titel
SSA-478960 V1.7 (Last Update: 2023-09-12): Missing CSRF Protection in the Web Server Login Page of Industrial Controllers
Veröffentlicht
12. September 2023 02:00
Text
The web server login page of affected products does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack.. Siemens has released updates for several affected products and recommends to update to the latest versions. ...
Titel
SSA-711309 V1.0: Denial of Service Vulnerability in the ANSI C OPC UA SDK of SIMATIC Products
Veröffentlicht
12. September 2023 02:00
Text
The ANSI C OPC UA implementation as used in several SIMATIC products contains a denial of service vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Siemens has released updates for several affected products and recommends to update ...
Titel
SSA-787941 V1.3 (Last Update: 2023-09-12): Denial of Service Vulnerability in RUGGEDCOM ROS V4
Veröffentlicht
12. September 2023 02:00
Text
RUGGEDCOM ROS-based V4 devices are vulnerable to a denial of service attack (Slowloris). By sending partial HTTP requests nonstop, with none completed, the affected web servers will be waiting for the completion of each request, occupying all available HTTP connections. The web server recovers by itself once the attack ends. ...
Titel
SSA-764801 V1.2 (Last Update: 2023-09-12): File Parsing Vulnerabilities in Tecnomatix Plant Simulation
Veröffentlicht
12. September 2023 02:00
Text
Siemens Tecnomatix Plant Simulation contains multiple vulnerabilities that could be triggered when the application reads PAR, SPP, STP and PRT files. If a user is tricked to open a malicious file using the affected application, this could lead to a crash, and potentially also to arbitrary code execution on the ...
Titel
SSA-712929 V2.3 (Last Update: 2023-09-12): Denial of Service Vulnerability in OpenSSL (CVE-2022-0778) Affecting Industrial Products
Veröffentlicht
12. September 2023 02:00
Text
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released updates for several affected products and recommends to update to the latest ...
Titel
SSA-450613 V1.1 (Last Update: 2023-09-12): Insyde BIOS Vulnerabilities in RUGGEDCOM APE1808 Product Family
Veröffentlicht
12. September 2023 02:00
Text
Insyde has published information on vulnerabilities in Insyde BIOS on November 8th 2022. These vulnerabilities also affect the RUGGEDCOM APE1808 product family. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSB-439005 V5.5 (Last Update: 2023-09-12): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Veröffentlicht
12. September 2023 02:00
Text
Titel
SSA-981975 V1.0: Information Disclosure Vulnerability in Intel-CPUs (CVE-2022-40982) Impacting SIMATIC IPCs
Veröffentlicht
12. September 2023 02:00
Text
Several Intel-CPU based SIMATIC IPCs are affected by an information exposure vulnerability (CVE-2022-40982) in the CPU that could allow an authenticated local user to potentially read other users’ data [1]. The issue is also known as “Gather Data Sampling” (GDS) or Downfall Attacks. For details refer to the chapter “Additional ...
Titel
SSA-957369 V1.0: Insyde BIOS Vulnerabilities in RUGGEDCOM APE1808 Product Family
Veröffentlicht
12. September 2023 02:00
Text
Insyde has published information on vulnerabilities in Insyde BIOS up to August 2023. These vulnerabilities also affect the RUGGEDCOM APE1808 product family. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-831302 V1.1 (Last Update: 2023-09-12): Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP V1.0
Veröffentlicht
12. September 2023 02:00
Text
Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP V1.0. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
Titel
SSA-147266 V1.0: Multiple Vulnerabilities in QMS Automotive before V12.39
Veröffentlicht
12. September 2023 02:00
Text
QMS Automotive before V12.39 contains multiple vulnerabilities that could allow an attacker to perform malicious code injection, information disclosure or lead to a denial of service condition. Siemens has released an update for QMS Automotive and recommends to update to the latest version.
Titel
SSA-190839 V1.0: X_T File Parsing Vulnerabilities in Parasolid
Veröffentlicht
12. September 2023 02:00
Text
Parasolid is affected by out of bounds write vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution in the context of ...
Titel
SSA-264814 V1.1 (Last Update: 2023-09-12): Timing Based Side Channel Vulnerability in the OpenSSL RSA Decryption in SIMATIC Products
Veröffentlicht
12. September 2023 02:00
Text
Several SIMATIC products are affected by a timing based side channel vulnerability in the OpenSSL RSA Decryption (CVE-2023-4304), as disclosed on 2023-02-07 at https://www.openssl.org/news/secadv/20230207.txt. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for ...
Titel
SSA-264815 V1.1 (Last Update: 2023-09-12): Type Confusion Vulnerability in OpenSSL X.400 Address Processing in SIMATIC Products
Veröffentlicht
12. September 2023 02:00
Text
Several SIMATIC products are affected by a type confusion vulnerability relating to OpenSSL X.400 address processing (CVE-2023-0286), as disclosed disclosed on 2023-02-07 at https://www.openssl.org/news/secadv/20230207.txt. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for ...
Titel
SSA-240541 V1.0: WIBU Systems CodeMeter Heap Buffer Overflow Vulnerability in Industrial Products
Veröffentlicht
12. September 2023 02:00
Text
WIBU Systems published information about a heap buffer overflow vulnerability and associated fix releases of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens industrial products for license management. The vulnerability is described in the section “Vulnerability Classification” below and got assigned the CVE ID CVE-2023-3935. ...
Titel
SSA-382653 V1.5 (Last Update: 2023-09-12): Multiple Denial of Service Vulnerabilities in Industrial Products
Veröffentlicht
12. September 2023 02:00
Text
Affected SIMATIC firmware contains multiple vulnerabilities that could allow an unauthenticated attacker to perform a denial of service attack under certain conditions. Siemens has released updates for the affected products and recommends to update to the latest versions.

Letzte Updates

BOSCH PSIRT
21.11.2023
CODESYS
28.06.2023
SIEMENS CERT
14.11.2023
US CERT
06.12.2023
US CERT (ICS)
07.12.2023

Nach Quelle

Archiv

2023
2022
2021
2020
2019
2018
2017

Feeds