Mai 2024
Titel
SSA-322980 V1.4 (Last Update: 2024-05-14): Denial of Service Vulnerability in SIPROTEC 5 Devices
Veröffentlicht
14. Mai 2024 02:00
Text
SIPROTEC 5 devices contain a null pointer dereference vulnerability in the web service. This could allow an attacker to send unauthenticated maliciously crafted http request that could cause denial of service condition of the device. Siemens has released new versions for several affected products and recommends to update to the ...
Titel
SSA-292022 V1.0: Vulnerability in Nozomi Guardian/CMC before 23.4.1 on RUGGEDCOM APE1808 devices
Veröffentlicht
14. Mai 2024 02:00
Text
Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC before 23.4.1. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. Customers are advised to consult and implement the workarounds ...
Titel
SSA-258494 V1.0: Stack Overflow Vulnerability in Simcenter Nastran before 2406.90
Veröffentlicht
14. Mai 2024 02:00
Text
Simcenter Nastran is affected by a stack overflow vulnerability that could be triggered when an application binary reads arbitrary string as a file argument. If a user is tricked to run one of the impacted application binary with a malicious string, an attacker could leverage the vulnerability to perform remote ...
Titel
SSA-832273 V1.2 (Last Update: 2024-05-14): Multiple Vulnerabilities in Fortigate NGFW before V7.4.3 on RUGGEDCOM APE1808 devices
Veröffentlicht
14. Mai 2024 02:00
Text
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Siemens recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
Titel
SSA-871704 V1.0: Multiple Vulnerabilities in SICAM Products
Veröffentlicht
14. Mai 2024 02:00
Text
Multiple SICAM products are affected by vulnerabilities that could lead to privilege escalation, remote code execution or information loss namely: SICAM A8000 device firmwares CPC80 for CP-8000/CP-8021/CP-8022 CPCI85 and OPUPI0 for CP-8031/CP-8050 SICAM EGS firmware CPCI85 and OPUPI0 SICAM 8 Software Solution SICORE Siemens has released new versions for the ...
Titel
SSA-647455 V1.2 (Last Update: 2024-05-14): Multiple Vulnerabilities in Nozomi Guardian/CMC before 22.6.2 on RUGGEDCOM APE1808 devices
Veröffentlicht
14. Mai 2024 02:00
Text
Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC before V22.6.2. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Customers are advised to consult and implement the ...
Titel
SSA-916916 V1.0: Security Vulnerabilities Fixed in RUGGEDCOM CROSSBOW V5.5
Veröffentlicht
14. Mai 2024 02:00
Text
The RUGGEDCOM CROSSBOW server application before V5.5 contains multiple vulnerabilities that could allow an attacker to execute arbitrary database queries via SQL injection attacks, or upload of arbitrary files to the application’s file system. The majority of the reported vulnerabilities might have a high impact in the availability of the ...
Titel
SSA-935500 V1.1 (Last Update: 2024-05-14): Denial of Service Vulnerability in FTP Server of Nucleus RTOS based APOGEE, TALON and Desigo PXC/PXM Products
Veröffentlicht
14. Mai 2024 02:00
Text
A denial of service vulnerability has been identified in the Nucleus RTOS (real-time operating system) and reported in the Siemens Security Advisory SSA-313313: https://cert-portal.siemens.com/productcert/html/ssa-313313.html. The products listed below use affected versions of the Nucleus software and inherently contain the vulnerability. Siemens has released new versions for several affected products and ...
Titel
SSA-711309 V1.8 (Last Update: 2024-05-14): Denial of Service Vulnerability in the OPC UA Implementations of SIMATIC Products
Veröffentlicht
14. Mai 2024 02:00
Text
The OPC UA implementations (ANSI C and C++) as used in several SIMATIC products contain a denial of service vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Siemens has released new versions for several affected products and ...
Titel
SSA-593272 V2.1 (Last Update: 2024-05-14): SegmentSmack in Interniche IP-Stack based Industrial Devices
Veröffentlicht
14. Mai 2024 02:00
Text
A vulnerability exists in affected products that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has released new versions for ...
Titel
SSA-976324 V1.0: Multiple IGS File Parsing Vulnerabilities in PS/IGES Parasolid Translator Component before V27.1.215
Veröffentlicht
14. Mai 2024 02:00
Text
PS/IGES Parasolid Translator Component contains multiple file parsing vulnerabilities that could be triggered when the application reads files in IGS file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary ...
Titel
SSA-999588 V1.3 (Last Update: 2024-05-14): Multiple Vulnerabilities in User Management Component (UMC) before V2.11.2
Veröffentlicht
14. Mai 2024 02:00
Text
Siemens User Management Component (UMC) before V2.11.2 is affected by multiple vulnerabilities where the most severe could lead to a restart of the UMC server. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends ...
Titel
SSA-871717 V1.2 (Last Update: 2024-05-14): Multiple Vulnerabilities in Polarion ALM
Veröffentlicht
14. Mai 2024 02:00
Text
Polarion ALM is affected by incorrect default path permissions in installation path, and improper authentication in the REST API endpoints of DOORS connector. An attacker could exploit the vulnerabilities for unauthenticated access, or privilege escalation. Siemens has released a new version for Polarion ALM and recommends to update to the ...
Titel
SSA-925850 V1.0: Improper Access Control in Polarion ALM
Veröffentlicht
14. Mai 2024 02:00
Text
The Apache Lucene based query engine in Polarion ALM lacks proper access controls. This could allow an authenticated user to query items beyond the user’s allowed projects. Siemens has released a new version for Polarion ALM and recommends to update to the latest version.
Titel
SSA-923361 V1.0: MODEL File Parsing Vulnerability in Tecnomatix Plant Simulation before V2302.0011
Veröffentlicht
14. Mai 2024 02:00
Text
Tecnomatix Plant Simulation contains an out of bounds write vulnerability that could be triggered when the application reads MODEL files. If a user is tricked to open a malicious file using the affected application, this could lead to a crash, and potentially also to arbitrary code execution on the target ...
Titel
SSA-968170 V1.3 (Last Update: 2024-05-14): Remote Code Execution Vulnerability in SIMATIC STEP 7 V5.x and Derived Products
Veröffentlicht
14. Mai 2024 02:00
Text
SIMATIC STEP 7 and PCS 7 contain a database management system that could allow remote users to use embedded functions of the database (local or in a network share) that have impact on the server. An attacker with network access to the server network could leverage these embedded functions to ...
Titel
SSA-712929 V2.7 (Last Update: 2024-05-14): Denial of Service Vulnerability in OpenSSL (CVE-2022-0778) Affecting Industrial Products
Veröffentlicht
14. Mai 2024 02:00
Text
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released new versions for several affected products and recommends to update to the ...
Titel
SSA-962515 V1.0: Out of Bounds Read Vulnerability in Industrial Products
Veröffentlicht
14. Mai 2024 02:00
Text
Several industrial products contain an out of bounds read vulnerability that could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel, leading to denial of service condition. Siemens has released new versions for several affected products and recommends to update to the ...
Titel
SSA-691715 V1.5 (Last Update: 2024-05-14): Vulnerability in OPC Foundation Local Discovery Server Affecting Siemens Products
Veröffentlicht
14. Mai 2024 02:00
Text
A vulnerability was identified in OPC Foundation Local Discovery Server which also affects Siemens products that could allow an attacker to escalate privileges under certain circumstances. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and ...
Titel
SSA-953710 V1.0: Vulnerabilities in the Network Communication Stack in Desigo Fire Safety UL and Cerberus PRO UL Fire Protection Systems
Veröffentlicht
14. Mai 2024 02:00
Text
Several products used in Desigo Fire Safety UL and Cerberus PRO UL Fire Protection Systems contain buffer overflow vulnerabilities in the network communication stack. Successful exploitation of the vulnerabilities could allow an unauthenticated attacker, who gained access to the fire protection system network, to execute arbitrary code on the affected ...
Titel
SSA-592380 V1.2 (Last Update: 2024-05-14): Denial of Service Vulnerability in SIMATIC S7-1500 CPUs and related products
Veröffentlicht
14. Mai 2024 02:00
Text
A vulnerability has been identified in the SIMATIC S7-1500 CPU family and related products that could allow an attacker to cause a denial of service condition. In order to exploit the vulnerability, an attacker must have access to the affected devices on port 102/tcp. Siemens has released updates for several ...
Titel
SSA-093430 V1.0: Multiple Vulnerabilities in SIMATIC RTLS Locating Manager before V3.0
Veröffentlicht
14. Mai 2024 02:00
Text
Siemens has released a new version for SIMATIC RTLS Locating Manager and recommends to update to the latest version.
Titel
SSA-148641 V1.2 (Last Update: 2024-05-14): XPath Constraint Vulnerability in Mendix Runtime
Veröffentlicht
14. Mai 2024 02:00
Text
A XPath Constraint vulnerability in the Mendix Runtime was discovered, that can affect the running applications. The vulnerability could allow a malicious user to deduce contents of inaccessible attributes and modify sensitive data. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Titel
SSA-455250 V1.1 (Last Update: 2024-05-14): Multiple Vulnerabilities in Palo Alto Networks Virtual NGFW on RUGGEDCOM APE1808 devices
Veröffentlicht
14. Mai 2024 02:00
Text
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Customers are advised to consult and implement the workarounds ...
Titel
SSA-046364 V1.0: X_T File Parsing Vulnerabilities in Parasolid
Veröffentlicht
14. Mai 2024 02:00
Text
Parasolid is affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the out of bounds read vulnerabilities to ...